Comprehensive estimation of patient radiation exposure in hip joint surgery using a tissue-equivalent phantom
Radiological Physics and Technology · 2026-06 · 19 (2) · 615-625
DOI: 10.1007/s12194-026-01030-4 ↗Kurz gefasst
Fachartikel in der Zeitschrift Radiological Physics and Technology, online erschienen am 06.03.2026. Verfasst von Eriko Koga und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiological Technology, Fukuoka University Hospital, Fukuoka city, Fukuoka, Japan. yahiro19@adm.fukuoka-u.ac.jp. Hauptthemen laut MEDLINE: Radiation Exposure, Hip Joint, Phantoms, Imaging. Die Arbeit nennt 29 Literaturangaben.
Abstract (Originalsprache)
When a patient undergoes radiographic diagnostic examinations, the physician is required to explain the risks of radiation exposure to the patient in advance. As the number of imaging procedures per patient increases, explanations of the effects of radiation exposure have become increasingly complex. Therefore, we estimated effective doses for patient exposure and examined the usefulness of the cumulative effective dose (CED), which can comprehensively evaluate multiple diagnostic examinations during the informed consent (IC) process.
Methods
Using multiple glass dosimeters and an anthropomorphic phantom, cumulative organ doses and CED were calculated for diagnostic examinations performed before and after hip surgery.
Results
Individual organ doses did not exceed the threshold for tissue reactions. The CED was less than 100 mSv, indicating that the radiation-induced health effects were classified as “low dose” ,meaning “no acute effects, subsequent additional cancer risk of less than 1%.” Conclusion: CED may serve as an effective tool for communicating radiation dose in relation to health risks. It enables clearer explanations of risks to patients undergoing multiple diagnostic examinations, and we expect that CED will help alleviate their concerns regarding radiographic diagnostic procedures.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiological Technology, Fukuoka University Hospital, Fukuoka city, Fukuoka, Japan. yahiro19@adm.fukuoka-u.ac.jp.
- Department of Radiological Technology, Fukuoka University Hospital, Fukuoka city, Fukuoka, Japan.
- Department of Health Sciences, Faculty of Medical Sciences, Kyushu University, Fukuoka city, Fukuoka, Japan.
- Department of Radiology, Faculty of Medicine, Fukuoka University Hospital, Fukuoka city, Fukuoka, Japan.
Zitieren
APA
Koga, E., Tominaga, K., Fujibuchi, T., Shigemori, S., Kozawa, Y., Ueno, T., Takayama, Y., & Yoshimitsu, K. (2026). Comprehensive estimation of patient radiation exposure in hip joint surgery using a tissue-equivalent phantom. Radiological Physics and Technology, 19(2), 615-625. https://doi.org/10.1007/s12194-026-01030-4
Vancouver
Koga E, Tominaga K, Fujibuchi T, Shigemori S, Kozawa Y, Ueno T, et al. Comprehensive estimation of patient radiation exposure in hip joint surgery using a tissue-equivalent phantom. Radiological Physics and Technology. 2026;19(2):615-625. doi:10.1007/s12194-026-01030-4
BibTeX
@article{Koga2026,
author = {Koga, Eriko and Tominaga, Kaori and Fujibuchi, Toshioh and Shigemori, Shinji and Kozawa, Yoshihiro and Ueno, Tokitaka and Takayama, Yukihisa and Yoshimitsu, Kengo},
title = {Comprehensive estimation of patient radiation exposure in hip joint surgery using a tissue-equivalent phantom},
journal = {Radiological Physics and Technology},
year = {2026},
volume = {19},
number = {2},
pages = {615--625},
doi = {10.1007/s12194-026-01030-4}
}
EUVIMED