EUVIMEDEUVIMED entdecken
Crossref

Comprehensive estimation of patient radiation exposure in hip joint surgery using a tissue-equivalent phantom

Eriko Koga, Kaori Tominaga, Toshioh Fujibuchi, Shinji Shigemori, Yoshihiro Kozawa, Tokitaka Ueno, Yukihisa Takayama, Kengo Yoshimitsu

Radiological Physics and Technology · 2026-06 · 19 (2) · 615-625

DOI: 10.1007/s12194-026-01030-4 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Radiological Physics and Technology, online erschienen am 06.03.2026. Verfasst von Eriko Koga und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiological Technology, Fukuoka University Hospital, Fukuoka city, Fukuoka, Japan. yahiro19@adm.fukuoka-u.ac.jp. Hauptthemen laut MEDLINE: Radiation Exposure, Hip Joint, Phantoms, Imaging. Die Arbeit nennt 29 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

When a patient undergoes radiographic diagnostic examinations, the physician is required to explain the risks of radiation exposure to the patient in advance. As the number of imaging procedures per patient increases, explanations of the effects of radiation exposure have become increasingly complex. Therefore, we estimated effective doses for patient exposure and examined the usefulness of the cumulative effective dose (CED), which can comprehensively evaluate multiple diagnostic examinations during the informed consent (IC) process.

Methods

Using multiple glass dosimeters and an anthropomorphic phantom, cumulative organ doses and CED were calculated for diagnostic examinations performed before and after hip surgery.

Results

Individual organ doses did not exceed the threshold for tissue reactions. The CED was less than 100 mSv, indicating that the radiation-induced health effects were classified as “low dose” ,meaning “no acute effects, subsequent additional cancer risk of less than 1%.” Conclusion: CED may serve as an effective tool for communicating radiation dose in relation to health risks. It enables clearer explanations of risks to patients undergoing multiple diagnostic examinations, and we expect that CED will help alleviate their concerns regarding radiographic diagnostic procedures.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Radiation ExposureHip JointPhantoms, ImagingHumansRadiation Dosage

Stichwörter der Autor:innen

Informed consentRadiation exposureRisk communicationcumulative effective dosefluorescent glass dosimeter

Autor:innen und Institutionen

  • Department of Radiological Technology, Fukuoka University Hospital, Fukuoka city, Fukuoka, Japan. yahiro19@adm.fukuoka-u.ac.jp.
  • Department of Radiological Technology, Fukuoka University Hospital, Fukuoka city, Fukuoka, Japan.
  • Department of Health Sciences, Faculty of Medical Sciences, Kyushu University, Fukuoka city, Fukuoka, Japan.
  • Department of Radiology, Faculty of Medicine, Fukuoka University Hospital, Fukuoka city, Fukuoka, Japan.

Zitieren

APA

Koga, E., Tominaga, K., Fujibuchi, T., Shigemori, S., Kozawa, Y., Ueno, T., Takayama, Y., & Yoshimitsu, K. (2026). Comprehensive estimation of patient radiation exposure in hip joint surgery using a tissue-equivalent phantom. Radiological Physics and Technology, 19(2), 615-625. https://doi.org/10.1007/s12194-026-01030-4

Vancouver

Koga E, Tominaga K, Fujibuchi T, Shigemori S, Kozawa Y, Ueno T, et al. Comprehensive estimation of patient radiation exposure in hip joint surgery using a tissue-equivalent phantom. Radiological Physics and Technology. 2026;19(2):615-625. doi:10.1007/s12194-026-01030-4

BibTeX
@article{Koga2026,
  author = {Koga, Eriko and Tominaga, Kaori and Fujibuchi, Toshioh and Shigemori, Shinji and Kozawa, Yoshihiro and Ueno, Tokitaka and Takayama, Yukihisa and Yoshimitsu, Kengo},
  title = {Comprehensive estimation of patient radiation exposure in hip joint surgery using a tissue-equivalent phantom},
  journal = {Radiological Physics and Technology},
  year = {2026},
  volume = {19},
  number = {2},
  pages = {615--625},
  doi = {10.1007/s12194-026-01030-4}
}
Kostenlos starten →