EUVIMEDEUVIMED entdecken
Crossref

Estimation of organ and effective doses for rotational cerebral angiography using the National Cancer Institute Dosimetry System for Radiography and Fluoroscopy (NCIRF)

Hitoshi Miyazaki, Toshioh Fujibuchi, Donghee Han, Koji Oura, Takahiro Kosoegawa, Hiroshi Hamasaki, Hideki Yoshikawa, Koichi Arimura, Toyoyuki Kato, Kousei Ishigami, Osamu Togao, Koji Yamashita

Radiological Physics and Technology · 2025-12 · 18 (4) · 1211-1220

DOI: 10.1007/s12194-025-00969-0 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Radiological Physics and Technology, online erschienen am 26.09.2025. Verfasst von Hitoshi Miyazaki und 11 weiteren Autor:innen. Beteiligte Einrichtung: Division of Radiology, Department of Medical Technology, Kyushu University Hospital, 3-1-1 Maidashi, Higashi-ku, Fukuoka, 812-8582, Japan. miyazaki.h…. Hauptthemen laut MEDLINE: Radiation Dosage, Radiometry, Cerebral Angiography, National Cancer Institute (U.S.). Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 32 Literaturangaben. Gefördert von: Japan Society for the Promotion of Science (JSPS).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Rotational cerebral angiography requires accurate dosimetry. The National Cancer Institute Dosimetry System for Radiography and Fluoroscopy (NCIRF), a Monte Carlo-based dosimetry software, can evaluate the organ dose (OD) and effective dose (ED) with higher accuracy than the conventional Monte Carlo software (PCXMC). We estimated the OD and ED for three-dimensional digital subtraction angiography (3D-DSA) and cone beam computed tomography (CBCT) using the NCIRF, reflecting dose variations during rotational cerebral angiography. The 3D-DSA and CBCT simulation parameters were obtained by rotational imaging of a physical head phantom using the Artis Q biplane system. The air kerma area product for each projection was determined based on the ratio of the tube current-time product for each projection; the NCIRF was used with male and female voxel-type reference computational phantoms. To validate the simulation results, the lens dose of the phantom was measured using radiophotoluminescence glass dosimeters and compared to the simulated lens dose. The highest ODs were delivered to the brain: 8.8 mGy (males) and 11.6 mGy (females) in 3D-DSA and 50.0 mGy (males) and 59.4 mGy (females) in CBCT. The EDs were 0.27 mSv (males) and 0.35 mSv (females) in 3D-DSA and 1.49 mSv (males) and 1.83 mSv (females) in CBCT. Lens doses differed within 8.0% between measurements and simulations, with 45.9-65.5% overestimation in simulations that did not account for dose variability. Simulations that considered dose variability using the NCIRF more accurately estimated OD and ED in rotational cerebral angiography.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Radiation DosageRadiometryCerebral AngiographyNational Cancer Institute (U.S.)HumansFluoroscopyPhantoms, ImagingMaleUnited StatesMonte Carlo MethodFemaleRotationCone-Beam Computed TomographyAngiography, Digital Subtraction

Stichwörter der Autor:innen

3D-DSACBCTDosimetryMonte Carlo simulationNCIRF

Autor:innen und Institutionen

  • Division of Radiology, Department of Medical Technology, Kyushu University Hospital, 3-1-1 Maidashi, Higashi-ku, Fukuoka, 812-8582, Japan. miyazaki.hitoshi.036@m.kyushu-u.ac.jp.
  • Division of Medical Quantum Science, Department of Health Sciences, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka, 812-8582, Japan. miyazaki.hitoshi.036@m.kyushu-u.ac.jp.
  • Division of Medical Quantum Science, Department of Health Sciences, Faculty of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka, 812-8582, Japan.
  • Division of Radiology, Department of Medical Technology, Kyushu University Hospital, 3-1-1 Maidashi, Higashi-ku, Fukuoka, 812-8582, Japan.
  • Department of Radiology, Fukuoka City Hospital, 13-1, Yoshizukahonmachi, Hakata-ku, Fukuoka, 812-0046, Japan.
  • Department of Neurosurgery, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka, 812-8582, Japan.

Förderung

  • Japan Society for the Promotion of Science (JSPS)

Zitieren

APA

Miyazaki, H., Fujibuchi, T., Han, D., Oura, K., Kosoegawa, T., Hamasaki, H., Yoshikawa, H., Arimura, K., Kato, T., Ishigami, K., Togao, O., & Yamashita, K. (2025). Estimation of organ and effective doses for rotational cerebral angiography using the National Cancer Institute Dosimetry System for Radiography and Fluoroscopy (NCIRF). Radiological Physics and Technology, 18(4), 1211-1220. https://doi.org/10.1007/s12194-025-00969-0

Vancouver

Miyazaki H, Fujibuchi T, Han D, Oura K, Kosoegawa T, Hamasaki H, et al. Estimation of organ and effective doses for rotational cerebral angiography using the National Cancer Institute Dosimetry System for Radiography and Fluoroscopy (NCIRF). Radiological Physics and Technology. 2025;18(4):1211-1220. doi:10.1007/s12194-025-00969-0

BibTeX
@article{Miyazaki2025,
  author = {Miyazaki, Hitoshi and Fujibuchi, Toshioh and Han, Donghee and Oura, Koji and Kosoegawa, Takahiro and Hamasaki, Hiroshi and Yoshikawa, Hideki and Arimura, Koichi and Kato, Toyoyuki and Ishigami, Kousei and Togao, Osamu and Yamashita, Koji},
  title = {Estimation of organ and effective doses for rotational cerebral angiography using the National Cancer Institute Dosimetry System for Radiography and Fluoroscopy (NCIRF)},
  journal = {Radiological Physics and Technology},
  year = {2025},
  volume = {18},
  number = {4},
  pages = {1211--1220},
  doi = {10.1007/s12194-025-00969-0}
}
Kostenlos starten →