EUVIMEDEUVIMED entdecken
Crossref

Deep learning-based correction for time truncation in cerebral computed tomography perfusion

Shota Ichikawa, Makoto Ozaki, Hideki Itadani, Hiroyuki Sugimori, Yohan Kondo

Radiological Physics and Technology · 2024

DOI: 10.1007/s12194-024-00818-6 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Radiological Physics and Technology, 2024. Verfasst von Shota Ichikawa und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiological Technology, School of Health Sciences, Faculty of Medicine, Niigata University, 2-746 Asahimachi-Dori, Chuo-ku, Niigata, 9…. Hauptthemen laut MEDLINE: Deep Learning, Tomography, X-Ray Computed, Image Processing, Computer-Assisted. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 31 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Cerebral computed tomography perfusion (CTP) imaging requires complete acquisition of contrast bolus inflow and washout in the brain parenchyma; however, time truncation undoubtedly occurs in clinical practice. To overcome this issue, we proposed a three-dimensional (two-dimensional + time) convolutional neural network (CNN)-based approach to predict missing CTP image frames at the end of the series from earlier acquired image frames. Moreover, we evaluated three strategies for predicting multiple time points. Seventy-two CTP scans with 89 frames and eight slices from a publicly available dataset were used to train and test the CNN models capable of predicting the last 10 image frames. The prediction strategies were single-shot prediction, recursive multi-step prediction, and direct-recursive hybrid prediction.Single-shot prediction predicted all frames simultaneously, while recursive multi-step prediction used prior predictions as input for subsequent steps, and direct-recursive hybrid prediction employed separate models for each step with prior predictions as input for the next step. The accuracies of the predicted image frames were evaluated in terms of image quality, bolus shape, and clinical perfusion parameters. We found that the image quality metrics were superior when multiple CTP images were predicted simultaneously rather than recursively. The bolus shape also showed the highest correlation (r = 0.990, p < 0.001) and the lowest variance (95% confidence interval, -453.26-445.53) in the single-shot prediction. For all perfusion parameters, the single-shot prediction had the smallest absolute differences from ground truth. Our proposed approach can potentially minimize time truncation errors and support the accurate quantification of ischemic stroke.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Deep LearningTomography, X-Ray ComputedImage Processing, Computer-AssistedHumansBrainTime FactorsPerfusion ImagingMaleFemale

Stichwörter der Autor:innen

3D U-NetCT perfusionDeep learningTime truncationTime-series prediction

Autor:innen und Institutionen

  • Department of Radiological Technology, School of Health Sciences, Faculty of Medicine, Niigata University, 2-746 Asahimachi-Dori, Chuo-ku, Niigata, 951-8518, Japan. ichikawa@clg.niigata-u.ac.jp.
  • Institute for Research Administration, Niigata University, 8050 Ikarashi 2-No-cho, Nishi-ku, Niigata, 950-2181, Japan. ichikawa@clg.niigata-u.ac.jp.
  • Department of Radiological Technology, Kurashiki Central Hospital, 1-1-1 Miwa, Kurashiki, Okayama, 710-8602, Japan.
  • Faculty of Health Sciences, Hokkaido University, Kita-12, Nishi-5, Kita-ku, Sapporo, 060-0812, Japan.
  • Department of Radiological Technology, School of Health Sciences, Faculty of Medicine, Niigata University, 2-746 Asahimachi-Dori, Chuo-ku, Niigata, 951-8518, Japan.

Zitieren

APA

Ichikawa, S., Ozaki, M., Itadani, H., Sugimori, H., & Kondo, Y. (2024). Deep learning-based correction for time truncation in cerebral computed tomography perfusion. Radiological Physics and Technology. https://doi.org/10.1007/s12194-024-00818-6

Vancouver

Ichikawa S, Ozaki M, Itadani H, Sugimori H, Kondo Y. Deep learning-based correction for time truncation in cerebral computed tomography perfusion. Radiological Physics and Technology. 2024. doi:10.1007/s12194-024-00818-6

BibTeX
@article{Ichikawa2024,
  author = {Ichikawa, Shota and Ozaki, Makoto and Itadani, Hideki and Sugimori, Hiroyuki and Kondo, Yohan},
  title = {Deep learning-based correction for time truncation in cerebral computed tomography perfusion},
  journal = {Radiological Physics and Technology},
  year = {2024},
  doi = {10.1007/s12194-024-00818-6}
}
Kostenlos starten →