Semi-quantitative tau PET approaches for Braak staging: concordance of CenTauRz and STOC with visual assessment
Annals of Nuclear Medicine · 2026-07 · 40 (7) · 786-794
DOI: 10.1007/s12149-026-02184-2 ↗Kurz gefasst
Fachartikel in der Zeitschrift Annals of Nuclear Medicine, online erschienen am 02.03.2026. Verfasst von Kaito Wachi und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiological Sciences, Graduate School of Health Sciences, Fukushima Medical University, 10-6 Sakaemachi, Fukushima-Shi, Fukushima, 960…. Hauptthemen laut MEDLINE: tau Proteins, Positron-Emission Tomography, Alzheimer Disease, Image Processing, Computer-Assisted. Die Arbeit nennt 41 Literaturangaben.
Abstract (Originalsprache)
OBJECTIVE: The progression of tau pathology in Alzheimer's disease (AD) is closely linked to cognitive decline. Visual Braak staging of tau PET reflects neurofibrillary tangle distribution but requires expertise in interpretation. The present study aimed to evaluate agreement between Braak stages and semi-quantitative CenTauRz and Simplified Temporal-Occipital Classification (STOC). METHODS: We collected data from 112 persons with normal cognition (NC), as well as 103 patients with mild cognitive impairment (MCI), and 48 with AD who were assessed by 1⁸F-flortaucipir PET and MRI in the ADNI3 study. A board-certified nuclear medicine physician visually assessed Braak stages on PET images. CenTauRz scores were derived by converting standardized uptake value ratios (SUVRs) from five predefined regions. STOC stages was based on SUVRs from four regions, and classified cognitive impairment into five stages of typical tau progression or atypical patterns. Tau positivity was defined as Braak stage ≥ IV, CenTauRz ≥ 2.0, or STOC stage ≥ 2/atypical. Concordance (Cohen's κ) and Spearman's correlations (rho, ρ) with Braak stages were calculated. RESULTS: The accuracy of CenTauRz compared to Braak stages was 0.84-0.90, κ = 0.61-0.77, and ρ = 0.67-0.83 and that of STOC was 0.87; κ = 0.71, and ρ = 0.81. CenTauRz captured the regional heterogeneity of tau accumulation, whereas STOC provided a staging framework aligned with Braak progression. CONCLUSION: The agreement of CenTauRz and STOC with visually assessed Braak stages was strong. Combinations of semi-quantitative methods might serve as complementary tools for tau PET images and improve interpretive reliability and objectivity.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Radiological Sciences, Graduate School of Health Sciences, Fukushima Medical University, 10-6 Sakaemachi, Fukushima-Shi, Fukushima, 960-8516, Japan.
- Department of Radiological Sciences, School of Health Sciences, Fukushima Medical University, 10-6 Sakaemachi, Fukushima-Shi, Fukushima, 960-8516, Japan.
- Department of Radiological Sciences, Graduate School of Health Sciences, Fukushima Medical University, 10-6 Sakaemachi, Fukushima-Shi, Fukushima, 960-8516, Japan. kenta5710@gmail.com.
- Department of Radiological Sciences, School of Health Sciences, Fukushima Medical University, 10-6 Sakaemachi, Fukushima-Shi, Fukushima, 960-8516, Japan. kenta5710@gmail.com.
- Nippon Medical School, Clinical Imaging Center for Healthcare, 1-12-15 Sendagi, Bunkyoku, Tokyo, 113-0022, Japan.
Zitieren
APA
Wachi, K., Yamao, T., Miwa, K., Miyaji, N., Akiya, N., Horikawa, T., Masubuchi, M., Kimura, S., & Matsuda, H. (2026). Semi-quantitative tau PET approaches for Braak staging: concordance of CenTauRz and STOC with visual assessment. Annals of Nuclear Medicine, 40(7), 786-794. https://doi.org/10.1007/s12149-026-02184-2
Vancouver
Wachi K, Yamao T, Miwa K, Miyaji N, Akiya N, Horikawa T, et al. Semi-quantitative tau PET approaches for Braak staging: concordance of CenTauRz and STOC with visual assessment. Annals of Nuclear Medicine. 2026;40(7):786-794. doi:10.1007/s12149-026-02184-2
BibTeX
@article{Wachi2026,
author = {Wachi, Kaito and Yamao, Tensho and Miwa, Kenta and Miyaji, Noriaki and Akiya, Naochika and Horikawa, Takuma and Masubuchi, Masaki and Kimura, Shu and Matsuda, Hiroshi},
title = {Semi-quantitative tau PET approaches for Braak staging: concordance of CenTauRz and STOC with visual assessment},
journal = {Annals of Nuclear Medicine},
year = {2026},
volume = {40},
number = {7},
pages = {786--794},
doi = {10.1007/s12149-026-02184-2}
}
EUVIMED