Comparative voxel-based dosimetry with pre-treatment Tc-99m SPECT/CT and post-treatment Y-90 PET/MRI for radioembolization with Y-90 microspheres
Annals of Nuclear Medicine · 2025
DOI: 10.1007/s12149-025-02052-5 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Annals of Nuclear Medicine, 2025. Verfasst von Burak Demir und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Nuclear Medicine, Sanliurfa Mehmet Akif Inan Education and Research Hospital, Sanliurfa, Turkey. 4burakfe@gmail.com. Hauptthemen laut MEDLINE: Yttrium Radioisotopes, Microspheres, Magnetic Resonance Imaging, Embolization, Therapeutic. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 24 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: University of Health Sciences.
Abstract (Originalsprache)
Purpose
The aim of this study was to investigate the differences between voxel-based dosimetry and the mean absorbed doses calculated with pre-treatment Tc-99 m-MAA SPECT/CT and post-treatment Y-90 PET/MR images. We also sought to present a detailed comparison of dose-volume histograms (DVHs) calculated from pre- and post-treatment imaging.
Methods
A total of 47 treatments and 41 patients were included in the analysis as six of the treatments were retreatments of the six patients. Multicompartment and voxel-based dosimetry were performed with pre-treatment Tc-99m-MAA SPECT/CT and Y-90 PET/MRI. Correlation coefficients between the two imaging methods for the mean absorbed dose of tumor, whole liver normal tissue, perfused normal tissue, T/N ratio and tumor D10, D50 and D90 values were calculated. Additionally, differences between these values were also evaluated with Bland–Altman plots.
Results
Pre-treatment Tc-99m-MAA SPECT/CT accurately predicted the dose values for healthy liver parenchyma calculated with Y-90 PET/MRI but showed lower accuracy in predicting T/N ratio and tumor doses. There were significant variations in tumor-absorbed doses for both glass and resin microspheres. Additionally, D90 values were higher when calculated with SPECT/CT than with PET/MRI, whereas D10 values were higher in PET/MRI compared to SPECT/CT.
Conclusion
The findings in our study suggest that Tc-99m-MAA SPECT/CT had higher accuracy in predicting the dose to the healthy liver parenchyma compared to the tumor, maintaining its importance in treatment planning.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Nuclear Medicine, Sanliurfa Mehmet Akif Inan Education and Research Hospital, Sanliurfa, Turkey. 4burakfe@gmail.com.
- Department of Nuclear Medicine, Ankara University Medical School, Ankara, Turkey.
- Department of Radiology, Ankara University Medical School, Ankara, Turkey.
- Department of Biostatistics, Ankara University Medical School, Ankara, Turkey.
Förderung
- University of Health Sciences
Zitieren
APA
Demir, B., Kucuk, N. O., Soydal, C., Celebioglu, E. C., Inal, G., Dursun, E., Bilgic, M. S., Kuru Oz, D., Elhan, A. H., & Kir, K. M. (2025). Comparative voxel-based dosimetry with pre-treatment Tc-99m SPECT/CT and post-treatment Y-90 PET/MRI for radioembolization with Y-90 microspheres. Annals of Nuclear Medicine. https://doi.org/10.1007/s12149-025-02052-5
Vancouver
Demir B, Kucuk NO, Soydal C, Celebioglu EC, Inal G, Dursun E, et al. Comparative voxel-based dosimetry with pre-treatment Tc-99m SPECT/CT and post-treatment Y-90 PET/MRI for radioembolization with Y-90 microspheres. Annals of Nuclear Medicine. 2025. doi:10.1007/s12149-025-02052-5
BibTeX
@article{Demir2025,
author = {Demir, Burak and Kucuk, Nuriye Ozlem and Soydal, Cigdem and Celebioglu, Emre Can and Inal, Gizem and Dursun, Ecenur and Bilgic, Mehmet Sadık and Kuru Oz, Digdem and Elhan, Atilla Halil and Kir, Kemal Metin},
title = {Comparative voxel-based dosimetry with pre-treatment Tc-99m SPECT/CT and post-treatment Y-90 PET/MRI for radioembolization with Y-90 microspheres},
journal = {Annals of Nuclear Medicine},
year = {2025},
doi = {10.1007/s12149-025-02052-5}
}
EUVIMED