Fully automatic categorical analysis of striatal subregions in dopamine transporter SPECT using a convolutional neural network
Annals of Nuclear Medicine · 2025
DOI: 10.1007/s12149-025-02038-3 ↗Kurz gefasst
Fachartikel in der Zeitschrift Annals of Nuclear Medicine, 2025. Verfasst von Thomas Buddenkotte und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Diagnostic and Interventional Radiology and Nuclear Medicine, University Medical Center Hamburg-Eppendorf, Hamburg, Germany. Hauptthemen laut MEDLINE: Convolutional Neural Networks, Corpus Striatum, Dopamine Plasma Membrane Transport Proteins, Image Processing, Computer-Assisted. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 67 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Bundesministerium für Wirtschaft und Energie, Universitätsklinikum Hamburg-Eppendorf (UKE).
Abstract (Originalsprache)
Objective
To provide fully automatic scanner-independent 5-level categorization of the [ 123 I]FP-CIT uptake in striatal subregions in dopamine transporter SPECT.
Methods
A total of 3500 [ 123 I]FP-CIT SPECT scans from two in house ( n = 1740, n = 640) and two external ( n = 645, n = 475) datasets were used for this study. A convolutional neural network (CNN) was trained for the categorization of the [ 123 I]FP-CIT uptake in unilateral caudate and putamen in both hemispheres according to 5 levels: normal, borderline, moderate reduction, strong reduction, almost missing. Reference standard labels for the network training were created automatically by fitting a Gaussian mixture model to histograms of the specific [ 123 I]FP-CIT binding ratio, separately for caudate and putamen and separately for each dataset. The CNN was trained on a mixed-scanner subsample ( n = 1957) and tested on one independent identically distributed (IID, n = 1068) and one out-of-distribution (OOD, n = 475) test dataset.
Results
The accuracy of the CNN for the 5-level prediction of the [ 123 I]FP-CIT uptake in caudate/putamen was 80.1/78.0% in the IID test dataset and 78.1/76.5% in the OOD test dataset. All 4 regional 5-level predictions were correct in 54.3/52.6% of the cases in the IID/OOD test dataset. A global binary score automatically derived from the regional 5-scores achieved 97.4/96.2% accuracy for automatic classification of the scans as normal or reduced relative to visual expert read as reference standard.
Conclusions
Automatic scanner-independent 5-level categorization of the [ 123 I]FP-CIT uptake in striatal subregions by a CNN model is feasible with clinically useful accuracy.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Diagnostic and Interventional Radiology and Nuclear Medicine, University Medical Center Hamburg-Eppendorf, Hamburg, Germany.
- Department of Nuclear Medicine, Charité, Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Berlin, Germany.
- Department of Diagnostic and Interventional Radiology and Nuclear Medicine, University Medical Center Hamburg-Eppendorf, Hamburg, Germany. r.buchert@uke.de.
Förderung
- Bundesministerium für Wirtschaft und Energie
- Universitätsklinikum Hamburg-Eppendorf (UKE)
Zitieren
APA
Buddenkotte, T., Lange, C., Klutmann, S., Apostolova, I., & Buchert, R. (2025). Fully automatic categorical analysis of striatal subregions in dopamine transporter SPECT using a convolutional neural network. Annals of Nuclear Medicine. https://doi.org/10.1007/s12149-025-02038-3
Vancouver
Buddenkotte T, Lange C, Klutmann S, Apostolova I, Buchert R. Fully automatic categorical analysis of striatal subregions in dopamine transporter SPECT using a convolutional neural network. Annals of Nuclear Medicine. 2025. doi:10.1007/s12149-025-02038-3
BibTeX
@article{Buddenkotte2025,
author = {Buddenkotte, Thomas and Lange, Catharina and Klutmann, Susanne and Apostolova, Ivayla and Buchert, Ralph},
title = {Fully automatic categorical analysis of striatal subregions in dopamine transporter SPECT using a convolutional neural network},
journal = {Annals of Nuclear Medicine},
year = {2025},
doi = {10.1007/s12149-025-02038-3}
}
EUVIMED