EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Quantitative evaluation of striatal uptake ratios using an adaptive template registration method for 123I-ioflupane dopamine transporter SPECT

Sunao Mizumura, Naoyuki Tamamura, Junya Ebina, Hikaru Watanabe, Masaaki Hori

Annals of Nuclear Medicine · 2024

DOI: 10.1007/s12149-024-01968-8 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Annals of Nuclear Medicine, 2024. Verfasst von Sunao Mizumura und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Toho University Omori Medical Center, 1‑1‑5, Omori‑nishi, Ota‑ku, Tokyo, 143‑8541, Japan. sunaom@med.toho-u.ac.jp. Hauptthemen laut MEDLINE: Tomography, Emission-Computed, Single-Photon, Nortropanes, Image Processing, Computer-Assisted, Dopamine Plasma Membrane Transport Proteins. Die Arbeit nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

123 I-FP-CIT ( 123 I-Ioflupane) SPECT shows strong accumulation in the striatum, but morphological standardization is challenging due to low accumulation outside the striatum, particularly in subjects with marked striatal decline. In this study, morphological standardization without MRI was achieved using the adaptive template registration (ATR) method to create a subject-specific optimized template with weighted images of normal-type and egg-shape-type templates. The accuracy of a quantitative method for calculating the ratio with nonspecific accumulation in the occipital lobe was evaluated by placing voxels-of-interest (VOI) on standardized images, particularly targeting the striatum.

Methods

The average images of eight subjects, demonstrating normal-type and egg-shape-type tracer accumulation in 123 I-Ioflupane SPECT, were utilized as normal and disease templates, respectively. The study included 300 subjects that underwent both 123 I-Ioflupane SPECT and MRI for the diagnosis of suspected Parkinson's disease or for exclusion diagnosis. Morphological standardization of SPECT images using structural MRI (MRI-based method) was considered the standard of truth (SOT). Three morphological standardizations without MRI were conducted. The first involved conventional morphological standardization using a normal template (fixed template method), the second employed the ATR method, with a weighted template, and the third used the split-ATR method, processing the left and right striatum separately to address asymmetrical accumulation. VOIs were set on the striatum, caudate, putamen as regions of specific accumulation, and on the occipital lobe as a reference region for nonspecific accumulation.

Results

Results showed significant and robust linearity in the striatal accumulation ratios for all templates when compared with the occipital lobe accumulation ratio when using the MRI-based method. Comparing intra-class correlations for different linearities, the ATR method and split-ATR method demonstrated higher linearity in the striatum, caudate, and putamen. The split-ATR method showed similar improvements, although more linearity than some of the ATR methods; the effectiveness of the Split-ATR method may vary by image quality, and further validation of its effectiveness in diverse asymmetric accumulation cases seemed warranted.

Conclusion

The use of optimized templates, such as the ATR and split-ATR methods, improved reproducibility in fully automated processing and demonstrated superior linearity compared to that of MRI-based method, in the ratio to the occipital lobe. The ATR method, which enables morphological standardization when using SPECT images only, proved highly reproducible for clinical quantitative analysis of striatal accumulation, facilitating its clinical use.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Tomography, Emission-Computed, Single-PhotonNortropanesImage Processing, Computer-AssistedDopamine Plasma Membrane Transport ProteinsHumansFemaleMaleMiddle AgedAgedAdultBiological TransportMagnetic Resonance ImagingCorpus StriatumParkinson DiseaseNeostriatumReference Standards

Stichwörter der Autor:innen

123I-IoflupaneAdapt template registration methodMorphological normalizationStriatal uptake ratio

Substanzen

ioflupaneNortropanesDopamine Plasma Membrane Transport Proteins

Autor:innen und Institutionen

  • Department of Radiology, Toho University Omori Medical Center, 1‑1‑5, Omori‑nishi, Ota‑ku, Tokyo, 143‑8541, Japan. sunaom@med.toho-u.ac.jp.
  • Nihon Medi-Physics Co., Ltd., 3‑4‑10, Shinsuna, Koto‑ku, Tokyo, 136‑0075, Japan.
  • Department of Neurology, Toho University Omori Medical Center, 1-1-5 Omori‑nishi, Ota‑ku, Tokyo, Japan.
  • Department of Radiology, Toho University Omori Medical Center, 1‑1‑5, Omori‑nishi, Ota‑ku, Tokyo, 143‑8541, Japan.

Zitieren

APA

Mizumura, S., Tamamura, N., Ebina, J., Watanabe, H., & Hori, M. (2024). Quantitative evaluation of striatal uptake ratios using an adaptive template registration method for 123I-ioflupane dopamine transporter SPECT. Annals of Nuclear Medicine. https://doi.org/10.1007/s12149-024-01968-8

Vancouver

Mizumura S, Tamamura N, Ebina J, Watanabe H, Hori M. Quantitative evaluation of striatal uptake ratios using an adaptive template registration method for 123I-ioflupane dopamine transporter SPECT. Annals of Nuclear Medicine. 2024. doi:10.1007/s12149-024-01968-8

BibTeX
@article{Mizumura2024,
  author = {Mizumura, Sunao and Tamamura, Naoyuki and Ebina, Junya and Watanabe, Hikaru and Hori, Masaaki},
  title = {Quantitative evaluation of striatal uptake ratios using an adaptive template registration method for 123I-ioflupane dopamine transporter SPECT},
  journal = {Annals of Nuclear Medicine},
  year = {2024},
  doi = {10.1007/s12149-024-01968-8}
}
Kostenlos starten →