Correlation between the thyroid computed tomography value and thyroid function in hyperthyroidism: a retrospective study
Annals of Nuclear Medicine · 2024
DOI: 10.1007/s12149-024-01938-0 ↗Kurz gefasst
Fachartikel in der Zeitschrift Annals of Nuclear Medicine, 2024. Verfasst von Haruna Iwanaga und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiological Technology, Nagoya University Hospital, Nagoya, Japan. Hauptthemen laut MEDLINE: Thyroid Gland, Tomography, X-Ray Computed, Hyperthyroidism. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 17 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Nagoya University.
Abstract (Originalsprache)
Objective
Radioiodine (I-131) therapy for hyperthyroidism is a well-established and safe treatment option. This study aimed to investigate the relationship between the computed tomography (CT) value and the function and volume of the thyroid gland by identifying the factors that induce changes in the CT value of patients with hyperthyroidism.
Methods
This retrospective study evaluated 38 patients with Graves’ disease and 10 patients with Plummer disease. To obtain the mean CT value and volume of the thyroid gland, the entire thyroid gland was set as the region of interest. A test dose of 3.7 MBq I-131 was administered before initiating I-131 therapy, and the radioiodine uptake (RIU) rate was assessed after 3, 24, 96, and 168 h. An approximate curve was plotted based on the RIU values obtained, and the effective half-life (EHL) was calculated. The correlation between the mean CT value and the volume of the thyroid gland, 24-h RIU, EHL, and the free triiodothyronine (FT3), free thyroxine (FT4), thyroid-stimulating hormone (TSH), and TSH receptor antibody (TRAb) levels was evaluated.
Results
The CT value exhibited a significant positive correlation with EHL in patients with Graves’ disease (r = 0.62, p < 0.0001) as well as patients with Plummer disease (r = 0.74, p < 0.05). However, it did not display any correlation with the remaining parameters.
Conclusion
The CT value is significantly correlated with EHL, suggesting that it reflects thyroid function and is mainly related to the factors associated with iodine discharge.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Radiological Technology, Nagoya University Hospital, Nagoya, Japan.
- Department of Radiological and Medical Laboratory Sciences, Department of Integrated Health Science, Nagoya University Graduate School of Medicine, Nagoya, Japan.
- Functional Medical Imaging, Biomedical Imaging Sciences, Division of Advanced Information Health Sciences, Department of Integrated Health Sciences, Nagoya University Graduate School of Medicine, Nagoya, Japan.
- , 1-20, Daikominami 1‑Chome, Higashi-Ku, Nagoya, 461-8673, Japan. katokt@med.nagoya-u.ac.jp.
Förderung
- Nagoya University
Zitieren
APA
Iwanaga, H., Fujita, N., Abe, S., Naganawa, S., & Kato, K. (2024). Correlation between the thyroid computed tomography value and thyroid function in hyperthyroidism: a retrospective study. Annals of Nuclear Medicine. https://doi.org/10.1007/s12149-024-01938-0
Vancouver
Iwanaga H, Fujita N, Abe S, Naganawa S, Kato K. Correlation between the thyroid computed tomography value and thyroid function in hyperthyroidism: a retrospective study. Annals of Nuclear Medicine. 2024. doi:10.1007/s12149-024-01938-0
BibTeX
@article{Iwanaga2024,
author = {Iwanaga, Haruna and Fujita, Naotoshi and Abe, Shinji and Naganawa, Shinji and Kato, Katsuhiko},
title = {Correlation between the thyroid computed tomography value and thyroid function in hyperthyroidism: a retrospective study},
journal = {Annals of Nuclear Medicine},
year = {2024},
doi = {10.1007/s12149-024-01938-0}
}
EUVIMED