EUVIMEDEUVIMED entdecken
Open Access

Comparison of 1-h with 3-h planar 99mTc-pyrophosphate scintigraphy in patients with suspected transthyretin cardiac amyloidosis using SPECT as a reference standard

Toshinori Saitou, Tadao Aikawa, Osamu Manabe, Atsushi Nagase, Tamaki Kudo, Noriko Oyama-Manabe

Annals of Nuclear Medicine · 2023-02 · 37 (2) · 99-107

DOI: 10.1007/s12149-022-01807-8 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Annals of Nuclear Medicine, online erschienen am 10.11.2022. Verfasst von Toshinori Saitou und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Hokkaido Cardiovascular Hospital, 1-30, Minami-27, Nishi-13, Chuo-ku, Sapporo, 064-8622, Japan. Hauptthemen laut MEDLINE: Cardiomyopathies, Amyloidosis, Kidney Diseases. Die Arbeit wurde bisher 19-mal zitiert (Crossref) und nennt 13 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

OBJECTIVES: The purpose of this study was to examine the diagnostic value of planar 99mTc-pyrophosphate (PYP) imaging at 1 and 3 h after tracer administration in patients with suspected transthyretin cardiac amyloidosis (ATTR-CA) using SPECT as a reference standard. We also tested whether blood pool activity of PYP is associated with renal dysfunction. METHODS: PYP images of 109 consecutive patients with suspected ATTR-CA were retrospectively reviewed. The myocardial PYP uptake was visually graded on a scale of 0 to 3 and quantified with the heart-to-contralateral (H/CL) ratio in accordance with the current expert consensus recommendations. The diagnostic value of planar images for identifying positive PYP SPECT was assessed by a receiver-operating characteristic curve analysis with the area under the curve (AUC). The uptake ratios of the ascending and descending aorta, left atrium, and trapezius muscle divided by the liver uptake were measured on SPECT images and compared to the renal function. RESULTS: A total of 41 patients (38%) had myocardial PYP uptake on SPECT images. In comparison with the visual scores on 1-h anterior planar images, those on 3-h anterior planar images had lower sensitivity (80.5% vs. 97.6%) and higher specificity (86.8% vs. 55.9%) for identifying positive PYP SPECT. The ROC analysis showed that the combination of visual scores on both 1-h and 3-h anterior planar images had significantly higher AUC values in comparison with 1-h anterior planar images alone (0.90 [95% CI 0.83-0.94] vs. 0.83 [95% CI 0.75-0.88]; P 0.05 for all). CONCLUSIONS: In the assessment of ATTR-CA using PYP imaging, visual scores on 3-h anterior planar images for identifying positive PYP SPECT had lower sensitivity and higher specificity in comparison with those on 1-h anterior planar images. The diagnostic value of the visual scores on 1-h and 3-h anterior planar images was not improved by adding the H/CL ratio. Blood pool activity of PYP was not significantly associated with renal dysfunction.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

CardiomyopathiesAmyloidosisKidney DiseasesHumansDiphosphatesPrealbuminTechnetium Tc 99m PyrophosphateRadiopharmaceuticalsRetrospective StudiesRadionuclide ImagingTomography, Emission-Computed, Single-Photon

Stichwörter der Autor:innen

99mTc-pyrophosphate scintigraphySingle-photon emission computed tomographyTransthyretin cardiac amyloidosis

Substanzen

diphosphoric acidDiphosphatesPrealbuminTechnetium Tc 99m PyrophosphateRadiopharmaceuticals

Autor:innen und Institutionen

  • Department of Radiology, Hokkaido Cardiovascular Hospital, 1-30, Minami-27, Nishi-13, Chuo-ku, Sapporo, 064-8622, Japan.
  • Department of Cardiology, Hokkaido Cardiovascular Hospital, 1-30, Minami-27, Nishi-13, Chuo-ku, Sapporo, 064-8622, Japan. tadao.aikawa@jichi.ac.jp.
  • Department of Radiology, Jichi Medical University Saitama Medical Center, 1-847 Amanuma-Cho, Omiya-ku, Saitama, 330-8503, Japan. tadao.aikawa@jichi.ac.jp.
  • Department of Radiology, Jichi Medical University Saitama Medical Center, 1-847 Amanuma-Cho, Omiya-ku, Saitama, 330-8503, Japan.

Zitieren

APA

Saitou, T., Aikawa, T., Manabe, O., Nagase, A., Kudo, T., & Oyama-Manabe, N. (2023). Comparison of 1-h with 3-h planar 99mTc-pyrophosphate scintigraphy in patients with suspected transthyretin cardiac amyloidosis using SPECT as a reference standard. Annals of Nuclear Medicine, 37(2), 99-107. https://doi.org/10.1007/s12149-022-01807-8

Vancouver

Saitou T, Aikawa T, Manabe O, Nagase A, Kudo T, Oyama-Manabe N. Comparison of 1-h with 3-h planar 99mTc-pyrophosphate scintigraphy in patients with suspected transthyretin cardiac amyloidosis using SPECT as a reference standard. Annals of Nuclear Medicine. 2023;37(2):99-107. doi:10.1007/s12149-022-01807-8

BibTeX
@article{Saitou2023,
  author = {Saitou, Toshinori and Aikawa, Tadao and Manabe, Osamu and Nagase, Atsushi and Kudo, Tamaki and Oyama-Manabe, Noriko},
  title = {Comparison of 1-h with 3-h planar 99mTc-pyrophosphate scintigraphy in patients with suspected transthyretin cardiac amyloidosis using SPECT as a reference standard},
  journal = {Annals of Nuclear Medicine},
  year = {2023},
  volume = {37},
  number = {2},
  pages = {99--107},
  doi = {10.1007/s12149-022-01807-8}
}
Kostenlos starten →