The Impact of Lesion-Specific and Sampling-Related Factors on Success of Salivary Gland Fine-Needle Aspiration Cytology
Head and Neck Pathology · 07.01.2025 · 19 (1)
DOI: 10.1007/s12105-024-01741-3 ↗Kurz gefasst
Fachartikel in der Zeitschrift Head and Neck Pathology, online erschienen am 07.01.2025. Verfasst von Marcel Mayer und 11 weiteren Autor:innen. Beteiligte Einrichtung: Department of Otorhinolaryngology, Head and Neck Surgery, Medical Faculty, University of Cologne, Cologne, Germany. marcel.mayer@uk-koeln.de. Hauptthemen laut MEDLINE: Salivary Gland Neoplasms. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Deutsche Forschungsgemeinschaft,Germany, Jean-Uhrmacher-Institut, Universitätsklinikum Köln.
Abstract (Originalsprache)
Purpose
Ultrasound-guided fine-needle aspiration cytology (FNAC) is a widely used diagnostic procedure which facilitates the differentiation of salivary gland lesions. Although the performance of salivary gland FNAC (SG-FNAC) has improved since the introduction of the Milan System for Reporting Salivary Gland Cytopathology (MSRSGC), the range of the reported performance is still wide. Therefore, the aim of this study was to determine lesion- and sampling-related factors that influence the success of SG-FNAC.
Methods
All SG-FNAC cases performed in a tertiary referral hospital between September 1st, 2011, and August 31st, 2022, were retrospectively identified. Demographic, histopathological, lesion-specific, and sampling-related data were retrieved from the clinical charts. Cytopathological reports were categorized according to the MSRSGC. The risk of malignancy (ROM), the performance measures, and factors influencing the success of SG-FNAC were calculated.
Results
Overall, 1289 cases with histopathological follow-up diagnosis (out of 1952 SG-FNACs) were included. The ROM was: non-diagnostic = 23.9%, non-neoplastic = 4.4%, atypia of undetermined significance (AUS) = 34.5%, neoplasm-benign = 1.0%, neoplasm-salivary gland neoplasm of uncertain malignant potential (SUMP) = 15.3%, suspicious for malignancy = 74.1%, malignant = 96.2%. The sensitivity, specificity, accuracy, positive, and negative predictive value for differentiating benign from malignant lesions (excluding lesions categorized as AUS and SUMP) were 87.5%, 97.7%, 96.3%, 85.0%, and 98.1%, respectively. A larger lesion size (OR (95% CI) = 1.21 (1.06–1.39), p = 0.004), a higher number of obtained slides (OR (95% CI) = 1.31 (1.17–1.46), p < 0.001), and the physician performing the FNAC (p = 0.047) were independent predictors for a higher success, while localization of the lesion within the submandibular compared to the parotid gland (OR (95% CI) = 0.38 (0.19–0.77), p = 0.008) was an independent predictor for lower success of SG-FNAC.
Conclusion
This is the largest single-center study evaluating SG-FNAC performance to date. It identified independent lesion-and sampling-related factors influencing the success of SG-FNAC. Knowledge of those can improve performance of the procedure.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Otorhinolaryngology, Head and Neck Surgery, Medical Faculty, University of Cologne, Cologne, Germany. marcel.mayer@uk-koeln.de.
- Department of Otorhinolaryngology, Head and Neck Surgery, Medical Faculty, University of Cologne, Cologne, Germany.
- Institute of Medical Statistics and Computational Biology, University of Cologne, Cologne, Germany.
- Medical Faculty, Institute of Pathology, University of Cologne, Cologne, Germany.
Förderung
- Deutsche Forschungsgemeinschaft,Germany
- Jean-Uhrmacher-Institut
- Universitätsklinikum Köln
Zitieren
APA
Mayer, M., Alfarra, M. M., Möllenhoff, K., Engels, M., Arolt, C., Quaas, A., Wolber, P., Jansen, L., Nachtsheim, L., Grosheva, M., Klussmann, J. P., & Shabli, S. (2025). The Impact of Lesion-Specific and Sampling-Related Factors on Success of Salivary Gland Fine-Needle Aspiration Cytology. Head and Neck Pathology, 19(1). https://doi.org/10.1007/s12105-024-01741-3
Vancouver
Mayer M, Alfarra MM, Möllenhoff K, Engels M, Arolt C, Quaas A, et al. The Impact of Lesion-Specific and Sampling-Related Factors on Success of Salivary Gland Fine-Needle Aspiration Cytology. Head and Neck Pathology. 2025;19(1). doi:10.1007/s12105-024-01741-3
BibTeX
@article{Mayer2025,
author = {Mayer, Marcel and Alfarra, Mohammad Marwan and Möllenhoff, Kathrin and Engels, Marianne and Arolt, Christoph and Quaas, Alexander and Wolber, Philipp and Jansen, Louis and Nachtsheim, Lisa and Grosheva, Maria and Klussmann, Jens Peter and Shabli, Sami},
title = {The Impact of Lesion-Specific and Sampling-Related Factors on Success of Salivary Gland Fine-Needle Aspiration Cytology},
journal = {Head and Neck Pathology},
year = {2025},
volume = {19},
number = {1},
doi = {10.1007/s12105-024-01741-3}
}
EUVIMED