Validation of Baveno VII criteria for clinically significant portal hypertension by two-dimensional shear wave elastography

Ruiling He, Chuan Liu, Ivica Grgurevic, Ying Guo, Huixiong Xu, Jiacheng Liu, Yunfang Liu, XiaoYan Wang, Hongmei Shi, Anita Madir, Kristian Podrug, Yuli Zhu und 7 weitere

Hepatology International · 2024

DOI: 10.1007/s12072-024-10657-7 ↗

Kurz gefasst

Multizentrische Studie in der Zeitschrift Hepatology International, 2024. Verfasst von Ruiling He und 18 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ultrasound, Donggang Branch of the First Hospital of Lanzhou University, Lanzhou, China. Hauptthemen laut MEDLINE: Elasticity Imaging Techniques, Hypertension, Portal. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 31 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: The Baveno VII consensus proposed criteria for the non-invasively diagnosis of clinically significant portal hypertension (CSPH) in patients with compensated advanced chronic liver disease (cACLD). The performance of Baveno VII criteria for assessing CSPH by two-dimensional shear wave elastography (2D-SWE) had not been well validated. We aimed to validate the performance of Baveno VII criteria for rule-in and rule-out CSPH by 2D-SWE. METHOD: This is an international multicenter study including cACLD patients from China and Croatia with paired liver stiffness measurement (LSM), spleen stiffness measurement (SSM) by 2D-SWE, and hepatic venous pressure gradient (HVPG) were included. CSPH was defined as HVPG ≥ 10 mmHg. RESULT: A total of 146 patients with cACLD were enrolled, and finally 118 patients were included in the analysis. Among them, CSPH was documented in 79 (66.9%) patients. Applying the Baveno VII criteria for rule-out CSPH by 2D-SWE, [LSM ≤ 15 kPa and platelet count ≥ 150 × 109/L] OR SSM 90% (93.5 or 98.7%) but negative predictive value < 90% (74.1 or 85.7%). Using the Baveno VII criteria for rule-in CSPH by 2D-SWE, LSM ≥ 25 kPa OR SSM ≥ 50 kPa, could diagnose CSPH with 100% specificity and 100% positive predictive values. CONCLUSION: Baveno VII criteria by 2D-SWE showed a good diagnostic performance for ruling in but not for ruling out CSPH, which might become an emerging non-invasive elastography tool to select the patients who needed non-selective beta blocker therapy.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Elasticity Imaging TechniquesHypertension, PortalHumansMaleFemaleMiddle AgedAdultAgedSensitivity and SpecificityChinaPredictive Value of TestsSpleenLiver

Stichwörter der Autor:innen

Baveno VII criteriaClinically significant portal hypertensionLiver stiffness measurementSpleen stiffness measurementTwo-dimensional shear wave elastography

Autor:innen und Institutionen

  • Department of Ultrasound, Donggang Branch of the First Hospital of Lanzhou University, Lanzhou, China.
  • The First Clinical Medical College of Lanzhou University, Lanzhou, China.
  • Center of Portal Hypertension, Department of Radiology, Zhongda Hospital, Medical School, Southeast University, Nurturing Center of Jiangsu Province for State Laboratory of AI Imaging & Interventional Radiology (Southea…
  • Basic Medicine Research and Innovation Center of Ministry of Education, Zhongda Hospital, Southeast University; State Key Laboratory of Digital Medical Engineering, Nanjing, China.
  • Department of Gastroenterology, Hepatology and Clinical Nutrition, School of Medicine and Faculty of Pharmacy and Biochemistry, University Hospital Dubrava, University of Zagreb, Zagreb, Croatia.
  • Department of Hepatology, The Third People's Hospital of Taiyuan, Taiyuan, China.

Zitieren

APA

He, R., Liu, C., Grgurevic, I., Guo, Y., Xu, H., Liu, J., Liu, Y., Wang, X., Shi, H., Madir, A., Podrug, K., Zhu, Y., Hua, Y., Wang, K., Wen, J., Su, M., Zhang, Q., Li, J., & Qi, X. (2024). Validation of Baveno VII criteria for clinically significant portal hypertension by two-dimensional shear wave elastography. Hepatology International. https://doi.org/10.1007/s12072-024-10657-7

Vancouver

He R, Liu C, Grgurevic I, Guo Y, Xu H, Liu J, et al. Validation of Baveno VII criteria for clinically significant portal hypertension by two-dimensional shear wave elastography. Hepatology International. 2024. doi:10.1007/s12072-024-10657-7

BibTeX
@article{He2024,
  author = {He, Ruiling and Liu, Chuan and Grgurevic, Ivica and Guo, Ying and Xu, Huixiong and Liu, Jiacheng and Liu, Yunfang and Wang, XiaoYan and Shi, Hongmei and Madir, Anita and Podrug, Kristian and Zhu, Yuli and Hua, Yongli and Wang, Kun and Wen, Jing and Su, Meiqin and Zhang, Qun and Li, Jie and Qi, Xiaolong},
  title = {Validation of Baveno VII criteria for clinically significant portal hypertension by two-dimensional shear wave elastography},
  journal = {Hepatology International},
  year = {2024},
  doi = {10.1007/s12072-024-10657-7}
}
Kostenlos starten →