A Novel Method of Management of High Output Chyle Leak Following Neck Dissection: Indocyanine Green Fluorescence-guided Robotic Transthoracic Thoracic Duct Ligation: A Case Series
Indian Journal of Otolaryngology and Head & Neck Surgery · 2024-12 · 76 (6) · 6041-6045
DOI: 10.1007/s12070-024-05079-8 ↗Kurz gefasst
Fachartikel in der Zeitschrift Indian Journal of Otolaryngology and Head & Neck Surgery, online erschienen am 24.09.2024. Verfasst von Kalaiarasi Raja und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Otorhinolaryngology, Jipmer, Puducherry, India. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 10 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
High-output Chyle leak is a dreadful complication following neck dissection, posing challenges in management due to the morbidity associated with prolonged leakage. This case series describes the efficacy of a novel Indocyanine Green (ICG) Fluorescence-guided Robotic Transthoracic thoracic duct ligation technique in intractable high-output chyle leaks following neck dissection. Three patients with persistent high-output chyle leaks following neck dissection underwent robot-assisted thoracic duct ligation. Preoperative evaluation, surgical technique, postoperative care, outcomes and follow-up were recorded. All patients experienced successful resolution of chyle leaks with no intraoperative complications. Postoperative recovery was uneventful, and no recurrences were observed during the follow-up period. ICG-guided robotic transthoracic thoracic duct ligation is a safe and effective method for managing persistent high-output chyle leaks following neck dissection, offering a minimally invasive technique with favourable outcomes.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Otorhinolaryngology, Jipmer, Puducherry, India.
- Department of Surgical Gastroenterology, Jipmer, Puducherry, India.
ORCID-Profile: Kalayarasan Raja, Akshat Kushwaha
Zitieren
APA
Raja, K., Raja, K., Kushwaha, A., Ganesan, S., Penubarthi, L. K., Paramasivam, S., & Alexander, A. (2024). A Novel Method of Management of High Output Chyle Leak Following Neck Dissection: Indocyanine Green Fluorescence-guided Robotic Transthoracic Thoracic Duct Ligation: A Case Series. Indian Journal of Otolaryngology and Head & Neck Surgery, 76(6), 6041-6045. https://doi.org/10.1007/s12070-024-05079-8
Vancouver
Raja K, Raja K, Kushwaha A, Ganesan S, Penubarthi LK, Paramasivam S, et al. A Novel Method of Management of High Output Chyle Leak Following Neck Dissection: Indocyanine Green Fluorescence-guided Robotic Transthoracic Thoracic Duct Ligation: A Case Series. Indian Journal of Otolaryngology and Head & Neck Surgery. 2024;76(6):6041-6045. doi:10.1007/s12070-024-05079-8
BibTeX
@article{Raja2024,
author = {Raja, Kalaiarasi and Raja, Kalayarasan and Kushwaha, Akshat and Ganesan, Sivaraman and Penubarthi, Lokesh Kumar and Paramasivam, Sabharisan and Alexander, Arun},
title = {A Novel Method of Management of High Output Chyle Leak Following Neck Dissection: Indocyanine Green Fluorescence-guided Robotic Transthoracic Thoracic Duct Ligation: A Case Series},
journal = {Indian Journal of Otolaryngology and Head & Neck Surgery},
year = {2024},
volume = {76},
number = {6},
pages = {6041--6045},
doi = {10.1007/s12070-024-05079-8}
}
EUVIMED