EUVIMEDEUVIMED entdecken
BeobachtungsstudieOpen Access · CC BY 4.0

Apnea Testing on Conventional Mechanical Ventilation During Brain Death Evaluation

Rameez Ali Merchant, Shahid Nafees Ahmad, Bradley Haddix, Craig Andrew Williamson, Teresa Lee Jacobs, Tarun Deep Singh, Andrew M Nguyen, Venkatakrishna Rajajee iD

Neurocritical Care · 2024

DOI: 10.1007/s12028-024-01990-8 ↗

Kurz gefasst

Beobachtungsstudie in der Zeitschrift Neurocritical Care, 2024. Verfasst von Rameez Ali Merchant und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Neurosurgery, University of Michigan, 3552 Taubman Health Care Center, SPC 5338, 1500 E. Medical Center Drive, Ann Arbor, MI, 48109-533…. Hauptthemen laut MEDLINE: Apnea, Brain Death, Respiration, Artificial. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 16 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

The use of continuous positive airway pressure has been shown to improve the tolerance of the apnea test, a critical component of brain death evaluation. The ability to deactivate the apnea backup setting has made apnea testing possible using several conventional mechanical ventilators. Our goal was to evaluate the safety and efficacy of apnea testing performed on mechanical ventilation, compared with the oxygen insufflation technique, for the determination of brain death.

Methods

This was a retrospective study. In 2016, our institution approved a change in policy to permit apnea testing on conventional mechanical ventilation. We examined the records of consecutive adults who underwent apnea testing as part of the brain death evaluation process between 2016 and 2022. Using an apnea test technique was decided at the discretion of the attending physician. Outcomes were successful apnea test and the occurrence of patient instability during the test. This included oxygen desaturation (SpO2) < 90%, hypotension (mean arterial pressure < 65 mm Hg despite titration of vasopressor), cardiac arrhythmia, pneumothorax, and cardiac arrest.

Results

Ninety-two adult patients underwent apnea testing during the study period: 58 (63%) with mechanical ventilation, 32 (35%) with oxygen insufflation, and 2 (2%) lacked documentation of technique. Apnea tests could not be completed successfully in 3 of 92 (3%) patients—two patients undergoing the oxygen insufflation technique (one patient with hypoxemia and one patient with hypotension) and one patient on mechanical ventilation (aborted for hemodynamic instability). Hypoxemia occurred in 4 of 32 (12.5%) patients with oxygen insufflation and in zero patients on mechanical ventilation ( p = 0.01). Hypotension occurred during 3 of 58 (5%) tests with mechanical ventilation and 4 of 32 (12.5%) tests with oxygen insufflation ( p = 0.24). In multivariate analysis, the use of oxygen insufflation was an independent predictor of patient instability during the apnea test (odds ratio 37.74, 95% confidence interval 2.74–520.14).

Conclusions

Apnea testing on conventional mechanical ventilation is feasible and offers several potential advantages over other techniques.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ApneaBrain DeathRespiration, ArtificialAdultAgedFemaleHumansMaleMiddle AgedContinuous Positive Airway PressureInsufflationOxygenRetrospective Studies

Stichwörter der Autor:innen

ApneaBrain deathMechanical ventilation

Substanzen

Oxygen

Autor:innen und Institutionen

  • Department of Neurosurgery, University of Michigan, 3552 Taubman Health Care Center, SPC 5338, 1500 E. Medical Center Drive, Ann Arbor, MI, 48109-5338, USA.
  • Department of Neurology, University of Michigan, Ann Arbor, MI, USA.
  • Southern Hills Hospital and Medical Center, Las Vegas, NV, USA.
  • Department of Respiratory Care, University of Michigan, Ann Arbor, MI, USA.
  • Department of Neurosurgery, University of Michigan, 3552 Taubman Health Care Center, SPC 5338, 1500 E. Medical Center Drive, Ann Arbor, MI, 48109-5338, USA. vrajajee@yahoo.com.
  • Department of Neurology, University of Michigan, Ann Arbor, MI, USA. vrajajee@yahoo.com.

ORCID-Profile: Venkatakrishna Rajajee

Zitieren

APA

Merchant, R. A., Ahmad, S. N., Haddix, B., Williamson, C. A., Jacobs, T. L., Singh, T. D., Nguyen, A. M., & Rajajee, V. (2024). Apnea Testing on Conventional Mechanical Ventilation During Brain Death Evaluation. Neurocritical Care. https://doi.org/10.1007/s12028-024-01990-8

Vancouver

Merchant RA, Ahmad SN, Haddix B, Williamson CA, Jacobs TL, Singh TD, et al. Apnea Testing on Conventional Mechanical Ventilation During Brain Death Evaluation. Neurocritical Care. 2024. doi:10.1007/s12028-024-01990-8

BibTeX
@article{Merchant2024,
  author = {Merchant, Rameez Ali and Ahmad, Shahid Nafees and Haddix, Bradley and Williamson, Craig Andrew and Jacobs, Teresa Lee and Singh, Tarun Deep and Nguyen, Andrew M and Rajajee, Venkatakrishna},
  title = {Apnea Testing on Conventional Mechanical Ventilation During Brain Death Evaluation},
  journal = {Neurocritical Care},
  year = {2024},
  doi = {10.1007/s12028-024-01990-8}
}
Kostenlos starten →