EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Non-destructive Through-Package Assessment of Salmon Fat Content Via Electrical Impedance Spectroscopy: A Preliminary Study

Fung Ee Lim, Yoshio Hagura

Food and Bioprocess Technology · 2026-07 · 19 (7)

DOI: 10.1007/s11947-026-04465-0 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Food and Bioprocess Technology, online erschienen am 30.06.2026. Verfasst von Fung Ee Lim und 1 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 72 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Hiroshima University.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study establishes the feasibility of using electrical impedance spectroscopy (EIS) as a non-destructive technique for assessing crude fat content in packaged salmon. Whole specimens of Coho salmon and Sockeye salmon were analyzed in various anatomical positions using a parallel circular plate electrode system. The electrical impedance |Z| and parallel capacitance Cp of the samples were measured at five representative frequencies between 100 Hz and 100 kHz in four progressive sample-preparation states: whole fish, half-section, fillet, and homogenized. Soxhlet extraction was applied to correlate the measured values with crude fat content, and the results were assessed using leave-one-out cross-validation (LOOCV). The resulting root mean square error of cross-validation (RMSECV), R2cv, and relative predictive deviation (RPD) were used as the primary prediction metrics. We found that sample thickness and tissue heterogeneity were important factors in determining prediction accuracy. Whole fish and half-section samples showed negligible correlations (R2cv < 0.53, RPD values < 1.5), whereas fillet preparations showed a strong correlation for Sockeye salmon (R2cv = 0.86, RPD = 2.23) and limited correlation for Coho salmon (R2cv = 0.44, RPD ≈ 1.2). The homogenized samples showed the highest correlation for both species (Sockeye: R2cv = 0.87, RPD = 2.43; Coho: R2cv = 0.71, RPD = 1.72). Notably, measuring through 0.075-mm polyethylene packaging yielded promising predictive correlations, which highlights the potential of through-package assessment. Thus, this study provides preliminary evidence of the technical feasibility of rapid fat assessment for commercial seafood quality control.

Förderung

  • Hiroshima University

Zitieren

APA

Lim, F. E., & Hagura, Y. (2026). Non-destructive Through-Package Assessment of Salmon Fat Content Via Electrical Impedance Spectroscopy: A Preliminary Study. Food and Bioprocess Technology, 19(7). https://doi.org/10.1007/s11947-026-04465-0

Vancouver

Lim FE, Hagura Y. Non-destructive Through-Package Assessment of Salmon Fat Content Via Electrical Impedance Spectroscopy: A Preliminary Study. Food and Bioprocess Technology. 2026;19(7). doi:10.1007/s11947-026-04465-0

BibTeX
@article{Lim2026,
  author = {Lim, Fung Ee and Hagura, Yoshio},
  title = {Non-destructive Through-Package Assessment of Salmon Fat Content Via Electrical Impedance Spectroscopy: A Preliminary Study},
  journal = {Food and Bioprocess Technology},
  year = {2026},
  volume = {19},
  number = {7},
  doi = {10.1007/s11947-026-04465-0}
}
Kostenlos starten →