EUVIMEDEUVIMED entdecken
Übersichtsarbeit

The Use of Uroflowmetry as a Diagnostic Test

Sanjay Sinha

Current Urology Reports · 2024-05 · 25 (5) · 99-107

DOI: 10.1007/s11934-024-01200-0 ↗

Kurz gefasst

Übersichtsarbeit in der Zeitschrift Current Urology Reports, online erschienen am 28.02.2024. Verfasst von Sanjay Sinha. Beteiligte Einrichtung: Department of Urology, Apollo Hospital, Hyderabad, India. drsanjaysinha@hotmail.com. Hauptthemen laut MEDLINE: Artificial Intelligence, Urologic Diseases. Die Arbeit wurde bisher 16-mal zitiert (Crossref) und nennt 50 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE OF REVIEW: Uroflowmetry is widely used for initial non-invasive evaluation of lower urinary tract disorders. Current clinical use is mostly restricted to a scrutiny of the maximum flow rate and uroflow pattern recorded by a conventional flowmeter in a health care facility. There are several advancements in our understanding and in available technologies that promise to transform clinical utilization of this simple test. RECENT FINDINGS: Several aspects of the uroflow test in addition to maximum flow rate and uroflow pattern show potential diagnostic utility. This includes flow acceleration, uroflow indices, uroflow-electromyography including lag time, stop uroflow test, and uroflow-based nomograms. There are initial attempts to use artificial intelligence in analysis. There is also new data with regard to factors influencing variability of uroflow testing that might influence the diagnostic value in as yet uncertain ways including diurnal variability, postural variability, locational variability, and operator variability. There are new technologies for uroflow testing in a home environment allowing for easy repetition. However, there are several challenges owing to a paucity of clinical data and standardization. There are also critical lacunae in terminology that need to be addressed. There are exciting new advancements in the field of uroflowmetry. However, there is need to standardize and validate the newer uroflow tracing analyses and technologies.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Artificial IntelligenceUrologic DiseasesHumansUrodynamicsUrinary BladderDiagnostic Tests, Routine

Stichwörter der Autor:innen

Lower urinary tract symptomsMaximum flow rateTerminologyUroflowmetry

Autor:innen und Institutionen

  • Department of Urology, Apollo Hospital, Hyderabad, India. drsanjaysinha@hotmail.com.

Zitieren

APA

Sinha, S. (2024). The Use of Uroflowmetry as a Diagnostic Test. Current Urology Reports, 25(5), 99-107. https://doi.org/10.1007/s11934-024-01200-0

Vancouver

Sinha S. The Use of Uroflowmetry as a Diagnostic Test. Current Urology Reports. 2024;25(5):99-107. doi:10.1007/s11934-024-01200-0

BibTeX
@article{Sinha2024,
  author = {Sinha, Sanjay},
  title = {The Use of Uroflowmetry as a Diagnostic Test},
  journal = {Current Urology Reports},
  year = {2024},
  volume = {25},
  number = {5},
  pages = {99--107},
  doi = {10.1007/s11934-024-01200-0}
}
Kostenlos starten →