Visual versus conventional intubation: comparison of SaCoVLM™ video laryngeal mask and direct laryngoscopy: a prospective observational study

Zeynep Baykara Başol, Emel Gündüz, Ayşe Gülbin Arıcı

Irish Journal of Medical Science (1971 -) · 07.11.2026

DOI: 10.1007/s11845-026-04715-2 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Irish Journal of Medical Science (1971 -), online erschienen am 07.11.2026. Verfasst von Zeynep Baykara Başol und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Anesthesiology and Reanimation, Akdeniz University, Antalya, Turkey. Die Arbeit nennt 27 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: The SaCoVLM™ video laryngeal mask (VLM) enables ventilation and visually guided intubation. This study compared the hemodynamic responses, intubation performance, and airway-related complications of SaCoVLM™ and direct laryngoscopy (DL) in elective surgery. METHODS: This prospective observational study included 204 adults undergoing general anesthesia between March and June 2024 (VLM, n = 103; DL, n = 101). Airway characteristics, first-attempt intubation success, procedure time, hemodynamic responses, and complications were evaluated. RESULTS: First-attempt intubation success was 89.3% in the VLM group and 81.2% in the DL group, with no statistically significant difference. Total procedure time was longer with VLM than with DL (37.4 vs. 27.6 s; p < 0.0001). Following intubation, increases in systolic and diastolic blood pressure, mean arterial pressure, and heart rate were more pronounced in the DL group. Airway-related complications were numerically less frequent with VLM, but between-group differences were not statistically significant. CONCLUSIONS: SaCoVLM™ was associated with less pronounced hemodynamic changes but a longer total procedure time than DL. Differences in first-attempt intubation success and airway-related complications were not statistically significant. Given the observational design and baseline differences in airway characteristics, these findings require cautious interpretation and confirmation in randomized studies.

Schlagwörter

Stichwörter der Autor:innen

Airway managementHemodynamicsIntubationVideo laryngoscopy

Autor:innen und Institutionen

  • Department of Anesthesiology and Reanimation, Akdeniz University, Antalya, Turkey.
  • Department of Anesthesiology and Reanimation, Akdeniz University, Antalya, Turkey. dregunduz@hotmail.com.

Zitieren

APA

Başol, Z. B., Gündüz, E., & Arıcı, A. G. (2026). Visual versus conventional intubation: comparison of SaCoVLM™ video laryngeal mask and direct laryngoscopy: a prospective observational study. Irish Journal of Medical Science (1971 -). https://doi.org/10.1007/s11845-026-04715-2

Vancouver

Başol ZB, Gündüz E, Arıcı AG. Visual versus conventional intubation: comparison of SaCoVLM™ video laryngeal mask and direct laryngoscopy: a prospective observational study. Irish Journal of Medical Science (1971 -). 2026. doi:10.1007/s11845-026-04715-2

BibTeX
@article{Baol2026,
  author = {Başol, Zeynep Baykara and Gündüz, Emel and Arıcı, Ayşe Gülbin},
  title = {Visual versus conventional intubation: comparison of SaCoVLM™ video laryngeal mask and direct laryngoscopy: a prospective observational study},
  journal = {Irish Journal of Medical Science (1971 -)},
  year = {2026},
  doi = {10.1007/s11845-026-04715-2}
}
Kostenlos starten →