Point-of-care ultrasound in Ireland: a cross-sectional survey of practice, education and governance among healthcare professionals
Irish Journal of Medical Science (1971 -) · 31.10.2026
DOI: 10.1007/s11845-026-04705-4 ↗Kurz gefasst
Querschnittstudie in der Zeitschrift Irish Journal of Medical Science (1971 -), online erschienen am 31.10.2026. Verfasst von Aine Lunney und 3 weiteren Autor:innen. Beteiligte Einrichtung: Radiography and Diagnostic Imaging, School of Medicine, University College Dublin, Dublin, Ireland. aine.lunney@ucd.ie. Die Arbeit nennt 47 Literaturangaben.
Abstract (Originalsprache)
Introduction
Anecdotal evidence suggests widespread Point-of-Care Ultrasound (POCUS) use in Ireland, but it is underexplored. Some professional societies have issued curricula and guidelines, but little is known about access to ultrasound education and guidance. This cross-sectional survey explores the current landscape of POCUS among healthcare professionals in Ireland.
Methods
A cross-sectional, online survey explored POCUS use, education pathways, and governance practices among healthcare professionals in Ireland. A novel 44-item survey was developed using SurveyMonkey and disseminated through national professional organisations from May–August 2023.
Results
From 411 responses, 38% ( n = 158/411) use or previously used POCUS, with the highest uptake in emergency medicine (67%, n = 68/101), intensive care (82%, n = 14/17), and anaesthesiology (81%, n = 13/16), likely due to recognised pathways. POCUS use remains low in general practice (31%, n = 15/49) and sports medicine (30%, n = 10/33). Governance concerns highlighted include 56% ( n = 78/139) of POCUS users operate within a scope of practice and 68% have no protocol for escalating incidental findings. 57% ( n = 59/103 store) store their images—72% ( n = 42/58) on the device itself, and 36% ( n = 21/58) on USB drives. Just 51% ( n = 77/151) had a mentor during their training. Respondents who completed competency assessments were significantly more likely to store their images (68% vs 40%, p = 0.006) and reported higher self-reported confidence scores for ultrasound machine parameters.
Conclusion
These findings provide an initial snapshot of the POCUS landscape in Ireland, highlighting both the high levels of interest and the uneven nature of current implementation.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Radiography and Diagnostic Imaging, School of Medicine, University College Dublin, Dublin, Ireland. aine.lunney@ucd.ie.
- Radiography and Diagnostic Imaging, School of Medicine, University College Dublin, Dublin, Ireland.
- Department of Emergency Medicine, Mater Misericordiae Hospital, Dublin, Ireland.
Zitieren
APA
Lunney, A., Cronin, K., McDermott, C., & Foley, S. (2026). Point-of-care ultrasound in Ireland: a cross-sectional survey of practice, education and governance among healthcare professionals. Irish Journal of Medical Science (1971 -). https://doi.org/10.1007/s11845-026-04705-4
Vancouver
Lunney A, Cronin K, McDermott C, Foley S. Point-of-care ultrasound in Ireland: a cross-sectional survey of practice, education and governance among healthcare professionals. Irish Journal of Medical Science (1971 -). 2026. doi:10.1007/s11845-026-04705-4
BibTeX
@article{Lunney2026,
author = {Lunney, Aine and Cronin, Kevin and McDermott, Cian and Foley, Shane},
title = {Point-of-care ultrasound in Ireland: a cross-sectional survey of practice, education and governance among healthcare professionals},
journal = {Irish Journal of Medical Science (1971 -)},
year = {2026},
doi = {10.1007/s11845-026-04705-4}
}
EUVIMED