EUVIMEDEUVIMED entdecken
Übersichtsarbeit

International primary hip arthroplasty registry review: findings from current reports

Gerard A Sheridan, Lisa C Howard, Michael E Neufeld, Nelson V Greidanus, Donald S Garbuz, Bassam A Masri

Irish Journal of Medical Science (1971 -) · 2023

DOI: 10.1007/s11845-023-03330-9 ↗

Kurz gefasst

Übersichtsarbeit in der Zeitschrift Irish Journal of Medical Science (1971 -), 2023. Verfasst von Gerard A Sheridan und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedics, University of British Columbia, Vancouver, BC, Canada. sheridga@tcd.ie. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Hip, Hip Prosthesis. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 21 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

We present key information from international registries in relation to primary total hip arthroplasty. The specific questions of interest include which bearings are superior in total hip arthroplasty (THA), which fixation types are optimal, do any specific implants perform better than others, and what is the latest update in the hip fracture setting? This is a comprehensive review of the major English-speaking hip arthroplasty registries across the globe. Key trends and developments in implant performance are identified and presented in the current article. Key points from review of all registries confirm that ceramic-on-polyethylene and metal-on-polyethylene continue to be the commonest bearings. The use of cemented femoral stems is increasing across most regions. Hybrid fixation is now the commonest fixation method in the UK for the first time in registry history. Uncemented femoral stems have a higher early revision rate for periprosthetic fracture than cemented stems across most regions. Dual mobility (DM) bearings are increasing in use and show higher early revision rates than unipolar bearings-they tend to be used for more complex indications (fracture/tumor/revision) and show similar revision rates to unipolar bearings when used exclusively in primary elective THA for osteoarthritis. We present current trends in THA based on current registry data from across the globe. Clinical signals of concern are emerging for THA uncemented femoral stem fixation and DM bearings in specific clinical contexts. These signals should be monitored across the literature in order to reduce the overall revision burden.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Arthroplasty, Replacement, HipHip ProsthesisHumansTreatment OutcomeRisk FactorsReoperationRegistriesPolyethylenesProsthesis DesignProsthesis Failure

Stichwörter der Autor:innen

ArthroplastyHipRegistryTHATHR

Substanzen

Polyethylenes

Autor:innen und Institutionen

  • Department of Orthopaedics, University of British Columbia, Vancouver, BC, Canada. sheridga@tcd.ie.
  • Department of Orthopaedics, University of British Columbia, Vancouver, BC, Canada.

Zitieren

APA

Sheridan, G. A., Howard, L. C., Neufeld, M. E., Greidanus, N. V., Garbuz, D. S., & Masri, B. A. (2023). International primary hip arthroplasty registry review: findings from current reports. Irish Journal of Medical Science (1971 -). https://doi.org/10.1007/s11845-023-03330-9

Vancouver

Sheridan GA, Howard LC, Neufeld ME, Greidanus NV, Garbuz DS, Masri BA. International primary hip arthroplasty registry review: findings from current reports. Irish Journal of Medical Science (1971 -). 2023. doi:10.1007/s11845-023-03330-9

BibTeX
@article{Sheridan2023,
  author = {Sheridan, Gerard A and Howard, Lisa C and Neufeld, Michael E and Greidanus, Nelson V and Garbuz, Donald S and Masri, Bassam A},
  title = {International primary hip arthroplasty registry review: findings from current reports},
  journal = {Irish Journal of Medical Science (1971 -)},
  year = {2023},
  doi = {10.1007/s11845-023-03330-9}
}
Kostenlos starten →