EUVIMEDEUVIMED entdecken
Crossref

Self-expandable transcatheter valve is a potentially useful option for a failing small surgical aortic bioprosthetic valve

Shohei Morita, Arudo Hiraoka, Genta Chikazawa, Shinya Takahashi, Taichi Sakaguchi, Hidenori Yoshitaka

General Thoracic and Cardiovascular Surgery · 2025

DOI: 10.1007/s11748-024-02048-4 ↗

Kurz gefasst

Fachartikel in der Zeitschrift General Thoracic and Cardiovascular Surgery, 2025. Verfasst von Shohei Morita und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiovascular Surgery, The Sakakibara Heart Institute of Okayama, 2-5-1 Nakaicho, Kita-Ku, Okayama, 700-0804, Japan. Hauptthemen laut MEDLINE: Heart Valve Prosthesis, Bioprosthesis, Aortic Valve, Prosthesis Failure. Die Arbeit nennt 20 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

OBJECTIVE: Trans-catheter aortic valve implantation inside a failing surgical aortic valve bio-prosthesis has become an alternative for patients at high risk for redo surgical aortic valve replacement. However, the correlation between the size of the failing surgical aortic valve and the occurrence of prosthesis-patient mismatch after trans-catheter implantation is still controversial. The aim of this study is to analyze and report the results in Japanese patients. METHODS: Thirty patients who underwent trans-catheter aortic valve implantation inside a failing surgical aortic valve at our hospital were retrospectively reviewed with results from echocardiography and computed tomography. RESULTS: The patients' mean age was 84.5 ± 4.8 years. The mean body surface area was 1.42 ± 0.13 m2. The cohort was divided into two groups according to the size of the failing bio-prosthesis: small (≦19 mm) and large (> 19 mm). There were no significant differences in mean pressure gradient (12.2 ± 4.0 mmHg vs. 11.1 ± 1.2 mmHg; p = 0.54) and effective orifice area index (1.00 ± 0.26 cm2/m2 vs. 0.99 ± 0.25 cm2/m2; p = 0.92) between the groups at 6 months after trans-catheter implantation. The incidence of moderate (38.5% vs. 28.6%; p = 0.59) and severe (0% vs. 7.1%; p = 0.33) prosthesis-patient mismatch was equivalent. There was no significant difference in survival between the two groups (log-rank test p-value = 0.08). CONCLUSIONS: Trans-catheter implantation inside a failing small aortic valve did not increase the frequency of prosthesis-patient mismatch in this Japanese cohort.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Heart Valve ProsthesisBioprosthesisAortic ValveProsthesis FailureProsthesis DesignTranscatheter Aortic Valve ReplacementHumansMaleFemaleAged, 80 and overRetrospective StudiesAgedJapanAortic Valve StenosisTreatment OutcomeReoperationHeart Valve Prosthesis Implantation

Stichwörter der Autor:innen

Prosthesis–patient mismatchRedo aortic valve replacementTAV in SAVTranscatheter aortic valve implantation

Autor:innen und Institutionen

  • Department of Cardiovascular Surgery, The Sakakibara Heart Institute of Okayama, 2-5-1 Nakaicho, Kita-Ku, Okayama, 700-0804, Japan.
  • Department of Cardiovascular Surgery, The Sakakibara Heart Institute of Okayama, 2-5-1 Nakaicho, Kita-Ku, Okayama, 700-0804, Japan. bassbord1028@yahoo.co.jp.
  • Department of Cardiovascular Surgery, Hiroshima University Hospital, Hiroshima, Japan.

Zitieren

APA

Morita, S., Hiraoka, A., Chikazawa, G., Takahashi, S., Sakaguchi, T., & Yoshitaka, H. (2025). Self-expandable transcatheter valve is a potentially useful option for a failing small surgical aortic bioprosthetic valve. General Thoracic and Cardiovascular Surgery. https://doi.org/10.1007/s11748-024-02048-4

Vancouver

Morita S, Hiraoka A, Chikazawa G, Takahashi S, Sakaguchi T, Yoshitaka H. Self-expandable transcatheter valve is a potentially useful option for a failing small surgical aortic bioprosthetic valve. General Thoracic and Cardiovascular Surgery. 2025. doi:10.1007/s11748-024-02048-4

BibTeX
@article{Morita2025,
  author = {Morita, Shohei and Hiraoka, Arudo and Chikazawa, Genta and Takahashi, Shinya and Sakaguchi, Taichi and Yoshitaka, Hidenori},
  title = {Self-expandable transcatheter valve is a potentially useful option for a failing small surgical aortic bioprosthetic valve},
  journal = {General Thoracic and Cardiovascular Surgery},
  year = {2025},
  doi = {10.1007/s11748-024-02048-4}
}
Kostenlos starten →