EUVIMEDEUVIMED entdecken
Crossref

Early thrombus formation including hypo-attenuated leaflet thrombosis after surgical bioprosthetic aortic valve replacement

Takanori Kono, Kazuyoshi Takagi, Tohru Takaseya, Tomofumi Fukuda, Kosuke Saku, Yasuyuki Zaima, Takahiro Shojima, Koichi Arinaga, Eiki Tayama

General Thoracic and Cardiovascular Surgery · 2024

DOI: 10.1007/s11748-024-02010-4 ↗

Kurz gefasst

Fachartikel in der Zeitschrift General Thoracic and Cardiovascular Surgery, 2024. Verfasst von Takanori Kono und 8 weiteren Autor:innen. Beteiligte Einrichtung: Division of Cardiovascular Surgery, Department of Surgery, Kurume University School of Medicine, 67 Asahi-machi, Kurume, Fukuoka, 830-0011, Japan. ko…. Hauptthemen laut MEDLINE: Bioprosthesis, Thrombosis, Heart Valve Prosthesis, Aortic Valve. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 22 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

OBJECTIVE: To assess the occurrence, predictors, and outcomes of hypo-attenuated leaflet thickening (HALT) and thrombus outside the prosthetic valve following surgical aortic valve replacement. METHODS: A total of 118 patients underwent surgical aortic valve replacement with bioprosthetic valves between July 2020 and June 2022. Sixty-two (52.5%) patients, which is a fairly high number of patients, underwent cardiac computed tomography and transthoracic echocardiography one week after surgery. Patients were divided into two groups, those with HALT (n = 14) and those without HALT (n = 48). RESULTS: Of the 62 patients who underwent cardiac computed tomography, HALT was observed in 14 (22.5%) patients during the very early postoperative phase. Reduced leaflet motion was observed in two of the 14 patients. The low-attenuation areas were located outside the prosthetic valve in 10 cases (71.4%) in the HALT group and in 14 cases (29.2%) in the non-HALT group. More than 50% of patients (57.1%) with HALT and 79.2% without HALT were administered warfarin. Neither in-hospital deaths nor postoperative thromboembolic events were observed during hospitalization. No patient had a mean pressure gradient > 20 mmHg in either group. CONCLUSION: HALT was observed in one-fifth of the cases after surgical aortic valve replacement during the very early postoperative phase in an institution wherein administration of continuous heparin infusion after surgery is a standard practice. HALT did not affect the early prognosis or incidence of cerebral infarction.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

BioprosthesisThrombosisHeart Valve ProsthesisAortic ValveHeart Valve Prosthesis ImplantationHumansFemaleMaleAgedMiddle AgedRetrospective StudiesAnticoagulantsAged, 80 and overTime FactorsTreatment OutcomeRisk FactorsEchocardiographyAortic Valve StenosisProsthesis Design

Stichwörter der Autor:innen

Aortic valve replacementBioprosthetic valveHypo-attenuated leaflet thrombosis

Substanzen

Anticoagulants

Autor:innen und Institutionen

  • Division of Cardiovascular Surgery, Department of Surgery, Kurume University School of Medicine, 67 Asahi-machi, Kurume, Fukuoka, 830-0011, Japan. kono_takanori@med.kurume-u.ac.jp.
  • Division of Cardiovascular Surgery, Department of Surgery, Kurume University School of Medicine, 67 Asahi-machi, Kurume, Fukuoka, 830-0011, Japan.

Zitieren

APA

Kono, T., Takagi, K., Takaseya, T., Fukuda, T., Saku, K., Zaima, Y., Shojima, T., Arinaga, K., & Tayama, E. (2024). Early thrombus formation including hypo-attenuated leaflet thrombosis after surgical bioprosthetic aortic valve replacement. General Thoracic and Cardiovascular Surgery. https://doi.org/10.1007/s11748-024-02010-4

Vancouver

Kono T, Takagi K, Takaseya T, Fukuda T, Saku K, Zaima Y, et al. Early thrombus formation including hypo-attenuated leaflet thrombosis after surgical bioprosthetic aortic valve replacement. General Thoracic and Cardiovascular Surgery. 2024. doi:10.1007/s11748-024-02010-4

BibTeX
@article{Kono2024,
  author = {Kono, Takanori and Takagi, Kazuyoshi and Takaseya, Tohru and Fukuda, Tomofumi and Saku, Kosuke and Zaima, Yasuyuki and Shojima, Takahiro and Arinaga, Koichi and Tayama, Eiki},
  title = {Early thrombus formation including hypo-attenuated leaflet thrombosis after surgical bioprosthetic aortic valve replacement},
  journal = {General Thoracic and Cardiovascular Surgery},
  year = {2024},
  doi = {10.1007/s11748-024-02010-4}
}
Kostenlos starten →