EUVIMEDEUVIMED entdecken
Beobachtungsstudie

Robotic and open repair of complex ventral and incisional hernias with the Tissue Approximating System (TAS): a pilot feasibility study

Michael A J Sawyer, Nicolas Zucchini, Michail Koutentakis, Christian A Macias, Abhirami Babu, Charles Egas, Alejandro González Ojeda, Luis Osvaldo Suárez Carreón, Aldo Daniel Tavarez Ortega, Miriam Andrea Gonzalez Gonzalez, Maile Sawyer, Aditya Vishnubhotla und 5 weitere

Journal of Robotic Surgery · 10.11.2026 · 20 (1)

DOI: 10.1007/s11701-026-04161-3 ↗

Kurz gefasst

Beobachtungsstudie in der Zeitschrift Journal of Robotic Surgery, online erschienen am 10.11.2026. Verfasst von Michael A J Sawyer und 16 weiteren Autor:innen. Beteiligte Einrichtung: University of Oklahoma School of Medicine, Oklahoma City, OK, USA. Hauptthemen laut MEDLINE: Incisional Hernia, Hernia, Ventral, Robotic Surgical Procedures, Herniorrhaphy. Die Arbeit nennt 22 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Achieving durable primary fascial closure (PFC) in complex ventral and incisional hernias (VIH) without generating excessive midline tension remains a formidable surgical challenge. This pilot study evaluates the feasibility and short-term safety of a novel mechanical fascial traction device, the Tissue Approximating System (TAS), with a historical cohort included to provide clinical context rather than a direct efficacy comparison. A retrospective, observational study evaluated 30 adult patients undergoing complex VIH repair utilizing the TAS with robotic and open approaches. A historical cohort of 50 patients undergoing standard PFC was included strictly to provide contextual baseline data on standard hernia repair morbidity rather than a matched efficacy comparator. Primary endpoints were 30-day postoperative morbidity, stratified by the Clavien-Dindo (CD) classification, and operative metrics, including total operative time (OT) and lysis of adhesions (LOA) time. Statistical analyses utilized independent t-tests, Mann-Whitney U, and Chi-square tests. Despite comparable demographics, the TAS cohort presented with significantly higher baseline anatomical complexity, including larger mean fascial defects (126.7 vs. 50.7 cm², p < 0.001), greater loss of domain (40.0% vs. 4.0%, p < 0.001), and higher rates of recurrent hernias (76.7% vs. 54.0%, p = 0.043). Total OT and LOA times were significantly longer in the TAS group (p < 0.001). Overall 30-day complication rates were not significantly different (40.0% vs. 30.0%, p = 0.301). The TAS cohort had a 0% incidence of life-threatening systemic complications (CD IV-V), with complications predominantly consisting of local wound events. Postoperative pain at two weeks was significantly lower in the investigational group (p = 0.006). At short-term follow-up, no clinical recurrences have been identified in the TAS group. The TAS device was a feasible mechanical adjunct that facilitated 100% PFC in this small cohort of complex hernia defects. These preliminary findings support further evaluation of TAS-assisted closure, including device-related safety, comparative effectiveness, and longer-term durability.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Incisional HerniaHernia, VentralRobotic Surgical ProceduresHerniorrhaphyHumansPilot ProjectsFeasibility StudiesFemaleMaleRetrospective StudiesMiddle AgedAgedOperative TimePostoperative ComplicationsFasciotomyTreatment OutcomeAdult

Stichwörter der Autor:innen

Abdominal wall reconstructionFascial tractionIncisional herniaPrimary fascial closureRobotic surgeryVentral hernia

Autor:innen und Institutionen

  • University of Oklahoma School of Medicine, Oklahoma City, OK, USA.
  • Oklahoma State University School of Medicine, Tahlequah, USA.
  • Memorial Health System of Southwest Oklahoma, Lawton, USA.
  • Department of Surgery, Nacogdoches Medical Center, Nacogdoches, TX, 75962, USA. nicolas.zucchini@aob.it.
  • ARNAS G. Brotzu, Metabolic and Obesity Surgery Unit, Cagliari, Italy. nicolas.zucchini@aob.it.
  • Surgical Excellence Academy, 1910 Pacific Ave, Suite 2000, #2747, Dallas, TX, 75201, USA. nicolas.zucchini@aob.it.

Zitieren

APA

Sawyer, M. A. J., Zucchini, N., Koutentakis, M., Macias, C. A., Babu, A., Egas, C., Ojeda, A. G., Carreón, L. O. S., Ortega, A. D. T., Gonzalez, M. A. G., Sawyer, M., Vishnubhotla, A., Samaan, M., Hernández, G. D., Orozco, C. F., Perez-Bonet, A., & Oviedo, R. J. (2026). Robotic and open repair of complex ventral and incisional hernias with the Tissue Approximating System (TAS): a pilot feasibility study. Journal of Robotic Surgery, 20(1). https://doi.org/10.1007/s11701-026-04161-3

Vancouver

Sawyer MAJ, Zucchini N, Koutentakis M, Macias CA, Babu A, Egas C, et al. Robotic and open repair of complex ventral and incisional hernias with the Tissue Approximating System (TAS): a pilot feasibility study. Journal of Robotic Surgery. 2026;20(1). doi:10.1007/s11701-026-04161-3

BibTeX
@article{Sawyer2026,
  author = {Sawyer, Michael A J and Zucchini, Nicolas and Koutentakis, Michail and Macias, Christian A and Babu, Abhirami and Egas, Charles and Ojeda, Alejandro González and Carreón, Luis Osvaldo Suárez and Ortega, Aldo Daniel Tavarez and Gonzalez, Miriam Andrea Gonzalez and Sawyer, Maile and Vishnubhotla, Aditya and Samaan, Mark and Hernández, Gonzalo Delgado and Orozco, Clotilde Fuentes and Perez-Bonet, Adolfo and Oviedo, Rodolfo J},
  title = {Robotic and open repair of complex ventral and incisional hernias with the Tissue Approximating System (TAS): a pilot feasibility study},
  journal = {Journal of Robotic Surgery},
  year = {2026},
  volume = {20},
  number = {1},
  doi = {10.1007/s11701-026-04161-3}
}
Kostenlos starten →