Surgeons’ Perception Questionnaire on Robotics (SPQR): development and preliminary validation of a surgeon-reported instrument for robotic surgery
Journal of Robotic Surgery · 2026
DOI: 10.1007/s11701-026-04090-1 ↗Kurz gefasst
Validierungsstudie in der Zeitschrift Journal of Robotic Surgery, 2026. Verfasst von Maria Chiara Sighinolfi und 51 weiteren Autor:innen. Beteiligte Einrichtung: Department of Urology, Fondazione Policlinico Agostino Gemelli IRCCS, Rome, RM, Italy. mariachiara.sighinolfi@policlinicogemelli.it. Hauptthemen laut MEDLINE: Robotic Surgical Procedures, Surgeons, Prostatectomy. Die Arbeit nennt 23 Literaturangaben.
Abstract (Originalsprache)
Robotic surgical platforms are diversifying, and clinical outcomes are increasingly comparable across systems, yet the console surgeon’s subjective experience remains poorly characterized. We developed a surgeon-reported questionnaire on robotic surgical systems and performed a preliminary psychometric evaluation in robotic radical prostatectomy. The Surgeons’ Perception Questionnaire on Robotics (SPQR) includes 31 five-point items in six domains: technical and operational aspects, key surgical tasks, ergonomics and physical comfort, communication and workflow integration, learning curve, and overall evaluation. In a cross-sectional web-based survey, surgeons rated the platform they primarily used for robotic radical prostatectomy. Internal consistency was assessed with polychoric-based Cronbach’s alpha and McDonald’s omega; exploratory (EFA) and confirmatory factor analysis (CFA) were performed in the same sample. Fifty-nine surgeons participated (response rate 42%); 81% evaluated the da Vinci Xi. Overall internal consistency was high (alpha 0.96; omega 0.97). Alpha and omega were ≥ 0.84 in five domains but below 0.70 for ergonomics and physical comfort (0.64 and 0.67). EFA suggested three factors (system performance and satisfaction; learning curve and training; ergonomics). CFA showed high incremental fit (comparative fit index 0.985) but inadequate absolute fit (root mean square error of approximation 0.097; standardized root mean square residual 0.135), and the ergonomics factor was weakly defined. The SPQR showed high internal consistency in most domains and a provisional multidimensional structure. Because the sample was small, highly experienced, predominantly male, and dominated by one platform, these findings require confirmation in larger independent cohorts before the SPQR is used for platform comparisons.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Urology, Fondazione Policlinico Agostino Gemelli IRCCS, Rome, RM, Italy. mariachiara.sighinolfi@policlinicogemelli.it.
- Department of Urology, Icahn School of Medicine at Mount Sinai, New York, NY, USA.
- Department of Urology, Fondazione Policlinico Agostino Gemelli IRCCS, Rome, RM, Italy.
- Big and Open Data Innovation Laboratory (BODaI-Lab), University of Brescia, Brescia, Italy.
- Department of Urology, Koç University School of Medicine, İstanbul, Turkey.
- Department of Urology, Kantonsspital Winterthur, Winterthur, Switzerland.
Zitieren
APA
Sighinolfi, M. C., Wiklund, P., Assumma, S., Sandri, M., Pallotta, G., Canda, E., Hubert, J., Hosseini, A., Harke, N., Graefen, M., Schiavina, R., Collins, J., Autorino, R., Annino, F., Secco, S., Moschovas, M. C., Senthil, N., De Groote, R., De Nayer, G., …, & Rocco, B. (2026). Surgeons’ Perception Questionnaire on Robotics (SPQR): development and preliminary validation of a surgeon-reported instrument for robotic surgery. Journal of Robotic Surgery. https://doi.org/10.1007/s11701-026-04090-1
Vancouver
Sighinolfi MC, Wiklund P, Assumma S, Sandri M, Pallotta G, Canda E, et al. Surgeons’ Perception Questionnaire on Robotics (SPQR): development and preliminary validation of a surgeon-reported instrument for robotic surgery. Journal of Robotic Surgery. 2026. doi:10.1007/s11701-026-04090-1
BibTeX
@article{Sighinolfi2026,
author = {Sighinolfi, Maria Chiara and Wiklund, Peter and Assumma, Simone and Sandri, Marco and Pallotta, Giuseppe and Canda, Erdem and Hubert, John and Hosseini, Abolfazl and Harke, Nina and Graefen, Markus and Schiavina, Riccardo and Collins, Justin and Autorino, Riccardo and Annino, Filippo and Secco, Silvia and Moschovas, Marcio Covas and Senthil, Nathan and De Groote, Ruben and De Nayer, Geert and Mottrie, Alex and Varca, Virginia and Lentini, Nicolo and Scuderi, Simone and Carrieri, Giuseppe and Falagario, Ugo and Bertolo, Riccardo and Breda, Alberto and Antonelli, Alessandro and Minervini, Andrea and Turri, Filippo and Totaro, Angelo and Bientinesi, Riccardo and Gandi, Carlo and Palermo, Giuseppe and Gavi, Filippo and Presutti, Simona and Panio, Enrico and Foschi, Nazario and Pinto, Francesco and Montesi, Marco and Rossi, Francesco and Russo, Pierluigi and Patel, Ela and Saikali, Shady and Ozawa, Yu and Gaia, Giorgia and Brusoni, Stefano and Giannarelli, Diana and Fagotti, Anna and Patel, Vipul and Alfieri, Sergio and Rocco, Bernardo},
title = {Surgeons’ Perception Questionnaire on Robotics (SPQR): development and preliminary validation of a surgeon-reported instrument for robotic surgery},
journal = {Journal of Robotic Surgery},
year = {2026},
doi = {10.1007/s11701-026-04090-1}
}
EUVIMED