Alternative set up strategies for upper tract robotic surgery with the Hugo RAS – experience from an early adopter institution
Journal of Robotic Surgery · 20.07.2026 · 20 (1)
DOI: 10.1007/s11701-026-03563-7 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Robotic Surgery, online erschienen am 20.07.2026. Verfasst von R A Keenan und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Urology, St. Vincent's Healthcare Group, Elm Park, Dublin 4, Ireland. Hauptthemen laut MEDLINE: Robotic Surgical Procedures, Nephrectomy, Urologic Surgical Procedures. Die Arbeit nennt 17 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: University College Dublin.
Abstract (Originalsprache)
The Hugo RAS (Medtronic) represents a growing alternative to the DaVinci robotic platform, featuring a distinctive modular arm-cart design that may pose challenges for surgeons transitioning from established systems. Arm-cart positioning, restricted assistant access, and risk of personnel injury have been identified as barriers to adoption. Following FDA approval for urological procedures in 2025, optimizing a standardized, ergonomic set-up for upper tract cases is essential to facilitate broader uptake. A retrospective analysis of a prospectively maintained database was performed at a single robot-naïve institution. All patients undergoing Hugo RAS upper tract procedures — including robot-assisted partial nephrectomy (RAPN), radical nephrectomy, pyeloplasty, and nephroureterectomy — from January 2024 to May 2025 were included. Perioperative outcomes, set-up times, intraoperative events, and arm-cart repositioning requirements were recorded. A unilateral, four posterior arm-cart configuration with a linear or “W” port arrangement was employed in all. 54 upper tract procedures were performed across two expert robotic surgeons. No cases required intraoperative arm-cart repositioning. Median set-up time for RAPN improved by 8 min between the first and last quartile of cases (15 to 7 min). One additional port was required in a nephroureterectomy case. One minor assistant injury occurred. One case required open conversion for vascular bleeding. RENAL nephrometry scores ranged from 4 to 11 (median 7), with 44% classified as moderate-to-high complexity. A unilateral posterior arm-cart configuration with linear port placement is feasible, reproducible, and familiar to DaVinci-experienced surgeons, improving ergonomics, workflow, and set-up efficiency for Hugo RAS upper tract procedures.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Urology, St. Vincent's Healthcare Group, Elm Park, Dublin 4, Ireland.
- Department of Urology, St. Vincent's Healthcare Group, Elm Park, Dublin 4, Ireland. Nikitabhatt@svhg.ie.
- School of Medicine, University College Dublin, Dublin 4, Ireland. Nikitabhatt@svhg.ie.
- Department of Surgical Affairs, Royal College of Surgeons in Ireland, Dublin 2, Ireland.
Förderung
- University College Dublin
Zitieren
APA
Keenan, R. A., Kelly, R., Moran, D., Bhatt, N. R., Breen, K. J., & McGuire, B. B. (2026). Alternative set up strategies for upper tract robotic surgery with the Hugo RAS – experience from an early adopter institution. Journal of Robotic Surgery, 20(1). https://doi.org/10.1007/s11701-026-03563-7
Vancouver
Keenan RA, Kelly R, Moran D, Bhatt NR, Breen KJ, McGuire BB. Alternative set up strategies for upper tract robotic surgery with the Hugo RAS – experience from an early adopter institution. Journal of Robotic Surgery. 2026;20(1). doi:10.1007/s11701-026-03563-7
BibTeX
@article{Keenan2026,
author = {Keenan, R A and Kelly, R and Moran, D and Bhatt, N R and Breen, K J and McGuire, B B},
title = {Alternative set up strategies for upper tract robotic surgery with the Hugo RAS – experience from an early adopter institution},
journal = {Journal of Robotic Surgery},
year = {2026},
volume = {20},
number = {1},
doi = {10.1007/s11701-026-03563-7}
}
EUVIMED