EUVIMEDEUVIMED entdecken
Vergleichsstudie

Robot-assisted versus manual total knee arthroplasty: precision without superiority in coronal alignment and patellar orientation

Carlos Peñaherrera-Carrillo, Susana Cabrera-Ávila, Francisco Endara Urresta, Alejandro Barros Castro, Eduardo Durán-Arce, Alejandro Gallegos-Tejeda, Carlos Javier Pineda Villaseñor, Carlos Suarez-Ahedo

Journal of Robotic Surgery · 2026

DOI: 10.1007/s11701-026-03149-3 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Journal of Robotic Surgery, 2026. Verfasst von Carlos Peñaherrera-Carrillo und 7 weiteren Autor:innen. Beteiligte Einrichtung: Adult Hip and Knee Reconstruction, National Rehabilitation Institute of Mexico, Mexico City, Mexico. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Knee, Robotic Surgical Procedures, Patella. Die Arbeit nennt 31 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Robot-assisted total knee arthroplasty (rTKA) has been proposed to improve precision in implant positioning and joint line restoration compared with manual TKA (mTKA). However, it remains unclear whether this increased accuracy results in superior functional or radiographic outcomes. This study aimed to compare mechanical alignment and patellofemoral restoration between robotic and manual techniques. A retrospective study including 600 consecutives primary TKAs performed from 2015 to 2024 was conducted. Patients were allocated into robotic (n = 300) and manual (n = 300) groups. All procedures were performed by the same arthroplasty team using a standardized surgical protocol and identical prosthesis model. Radiographic assessment included femorotibial mechanical axis and patellar orientation at a minimum of 12 months. Alignment was considered adequate when the absolute angular discrepancy was ≤ 2°. Statistical analyses included χ² tests, Student’s t-tests, and equivalence testing with the Two One-Sided Tests (TOST) method. Baseline demographics were comparable between groups. All knees achieved alignment within the ≤ 2° tolerance (100% vs. 100%). Mean angular discrepancy showed no significant differences (manual 0.52° vs. robotic 0.48°; p = 0.37). The robotic technique achieved a higher rate of exact matches (64% vs. 52%), while both remained within clinically accepted limits. Equivalence and non-inferiority analyses confirmed statistically and clinically equivalent outcomes between techniques. Robot-assisted TKA provides greater geometric precision; however, this advantage does not translate into measurable clinical or radiographic superiority when the manual technique is performed under a standardized protocol by experienced surgeons. Both methods demonstrated equivalent performance in restoring mechanical alignment and patellofemoral relationships. LEVEL OF EVIDENCE: III. Retrospective comparative study.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Arthroplasty, Replacement, KneeRobotic Surgical ProceduresPatellaHumansRetrospective StudiesFemaleAgedMiddle AgedKnee Joint

Stichwörter der Autor:innen

Arthroplasty, replacement, kneeKnee jointPatellaRadiographic image interpretation, computer-assistedRobotics

Autor:innen und Institutionen

  • Adult Hip and Knee Reconstruction, National Rehabilitation Institute of Mexico, Mexico City, Mexico.
  • National Autonomous University of Mexico, Mexico City, Mexico.
  • Articular Surgery, National Rehabilitation Institute of Mexico, Mexico City, Mexico.
  • Orthopedics and Traumatology, Arhtros Clinic, Quito, Ecuador.
  • Orthopedics and Traumatology, Metropolitan Hospital, International University of Ecuador, Quito, Ecuador.
  • National Rehabilitation Institute of Mexico, Mexico City, Mexico.

Zitieren

APA

Peñaherrera-Carrillo, C., Cabrera-Ávila, S., Urresta, F. E., Barros Castro, A., Durán-Arce, E., Gallegos-Tejeda, A., Villaseñor, C. J. P., & Suarez-Ahedo, C. (2026). Robot-assisted versus manual total knee arthroplasty: precision without superiority in coronal alignment and patellar orientation. Journal of Robotic Surgery. https://doi.org/10.1007/s11701-026-03149-3

Vancouver

Peñaherrera-Carrillo C, Cabrera-Ávila S, Urresta FE, Barros Castro A, Durán-Arce E, Gallegos-Tejeda A, et al. Robot-assisted versus manual total knee arthroplasty: precision without superiority in coronal alignment and patellar orientation. Journal of Robotic Surgery. 2026. doi:10.1007/s11701-026-03149-3

BibTeX
@article{PeaherreraCarrillo2026,
  author = {Peñaherrera-Carrillo, Carlos and Cabrera-Ávila, Susana and Urresta, Francisco Endara and Barros Castro, Alejandro and Durán-Arce, Eduardo and Gallegos-Tejeda, Alejandro and Villaseñor, Carlos Javier Pineda and Suarez-Ahedo, Carlos},
  title = {Robot-assisted versus manual total knee arthroplasty: precision without superiority in coronal alignment and patellar orientation},
  journal = {Journal of Robotic Surgery},
  year = {2026},
  doi = {10.1007/s11701-026-03149-3}
}
Kostenlos starten →