Intraoperative outcomes of robotic surgery across multiple multimodal systems
Journal of Robotic Surgery · 19.01.2026 · 20 (1)
DOI: 10.1007/s11701-025-03060-3 ↗Kurz gefasst
Beobachtungsstudie in der Zeitschrift Journal of Robotic Surgery, online erschienen am 19.01.2026. Verfasst von Antonio Fioccola und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Health Sciences, University of Milan, Milan, Italy. Hauptthemen laut MEDLINE: Robotic Surgical Procedures. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Università degli Studi di Milano.
Abstract (Originalsprache)
Background
The emergence of new multi-modular robotic surgical systems, such as Hugo RAS and Versius, introduces architectural and ergonomic variations compared with the established Da Vinci platform. While their surgical performance has been widely investigated, limited data exist regarding anesthesiological outcomes. This study aimed to compare intraoperative anesthetic parameters across three robotic platforms in a tertiary academic center.
Methods
A retrospective observational analysis was conducted on 258 consecutive patients who underwent robotic abdominal, urological, or gynecological surgery between January 2024 and June 2025. Patients were stratified according to the robotic platform used—Da Vinci, Hugo RAS, or Versius. Intraoperative variables, including Trendelenburg angle, anesthesia duration, pneumoperitoneum time, urine output, and fluid balance, were compared among groups.
Results
The Da Vinci system was used in 68.6% of cases, followed by Versius (15.9%) and Hugo RAS (15.5%). No major differences were observed in anesthesiological or postoperative outcomes across platforms, except for a higher intraoperative urine output with Versius in gynecological surgery. Minor variations included a steeper Trendelenburg position in colorectal surgeries performed with Da Vinci and shorter operative and pneumoperitoneum times with Versius in abdominal wall procedures.
Conclusion
Despite structural and ergonomic differences, the Hugo RAS and Versius systems demonstrated anesthesiological safety and intraoperative performance comparable to the Da Vinci platform, supporting their safe integration into clinical practice.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Health Sciences, University of Milan, Milan, Italy.
- Department of Anesthesia and Intensive Care, ASST Santi Paolo e Carlo, San Paolo University Hospital, Via Di Rudinì 9, Milan, Italy.
- Department of Health Sciences, General Surgery Unit, University of Milan, Milan, Italy.
- Department of Urology, Fondazione Policlinico Universitario A. Gemelli IRCCS, Rome, Italy.
- Università Cattolica del Sacro Cuore, Rome, Italy.
- Department of Health Sciences, University of Milan, Milan, Italy. davide.chiumello@unimi.it.
Förderung
- Università degli Studi di Milano
Zitieren
APA
Fioccola, A., Angioni, I., Fratti, I., Monte, A., Sighinolfi, M. C., Rocco, B., Bianchi, P. P., & Chiumello, D. (2026). Intraoperative outcomes of robotic surgery across multiple multimodal systems. Journal of Robotic Surgery, 20(1). https://doi.org/10.1007/s11701-025-03060-3
Vancouver
Fioccola A, Angioni I, Fratti I, Monte A, Sighinolfi MC, Rocco B, et al. Intraoperative outcomes of robotic surgery across multiple multimodal systems. Journal of Robotic Surgery. 2026;20(1). doi:10.1007/s11701-025-03060-3
BibTeX
@article{Fioccola2026,
author = {Fioccola, Antonio and Angioni, Ilaria and Fratti, Isabella and Monte, Alessandro and Sighinolfi, Maria Chiara and Rocco, Bernardo and Bianchi, Paolo Pietro and Chiumello, Davide},
title = {Intraoperative outcomes of robotic surgery across multiple multimodal systems},
journal = {Journal of Robotic Surgery},
year = {2026},
volume = {20},
number = {1},
doi = {10.1007/s11701-025-03060-3}
}
EUVIMED