Operative efficiency and safety outcomes: single-port versus multi-port robotic-assisted peritoneal flap vaginoplasty
Journal of Robotic Surgery · 11.12.2025 · 20 (1)
DOI: 10.1007/s11701-025-03041-6 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Journal of Robotic Surgery, online erschienen am 11.12.2025. Verfasst von Jennifer R Goldman und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Plastic Surgery, University of Virginia, 1300 Jefferson Park Avenue, Charlottesville, VA, 22903, USA. jrg4ex@gwmail.gwu.edu. Hauptthemen laut MEDLINE: Robotic Surgical Procedures, Vagina, Surgical Flaps, Plastic Surgery Procedures. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 24 Literaturangaben.
Abstract (Originalsprache)
INTRODUCTION: Robotic-assisted surgery has advanced reconstructive procedures, including peritoneal flap vaginoplasty (PFV), where both single-port and multi-port robotic systems are used. However, there remains debate regarding comparative efficacy, safety, and overall patient benefits of these two approaches. This paper aims to evaluate the outcomes of single-port versus multi-port robotic systems in PFV, focusing on operative efficiency and patient safety. METHODS: We retrospectively reviewed all patients who underwent robotic-assisted PFV between September 2021 and May 2024. All procedures were led by the same surgical team. Demographic and postoperative data were collected. Operative details, such as the type of robotic system used (single-port vs. multi-port), procedure length, and estimated costs were also recorded. Statistical analysis was conducted using IBM SPSS software. P-values of 0.05). Mean operative time in the multiport cohort was 264 min compared to 204 min in the single-port cohort (p < 0.001). The single-port approach yielded a mean estimated cost savings of $6,960 (p < 0.001) There was no statistically significant difference in acute postoperative complications between cohorts. CONCLUSION: This retrospective review demonstrates that single-port robotic-assisted peritoneal flap vaginoplasty (PFV) is associated with significantly shorter operative times and lower total costs compared to multi-port procedures. These findings suggest that the single-port approach may offer enhanced surgical efficiency without compromising patient safety.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Plastic Surgery, University of Virginia, 1300 Jefferson Park Avenue, Charlottesville, VA, 22903, USA. jrg4ex@gwmail.gwu.edu.
- Department of Plastic Surgery, University of Virginia, 1300 Jefferson Park Avenue, Charlottesville, VA, 22903, USA.
Zitieren
APA
Goldman, J. R., Yanoshak, E. C., Kareddy, A., Kumar, A., Pawly, J. M., Corbett, S., & Stranix, J. T. (2025). Operative efficiency and safety outcomes: single-port versus multi-port robotic-assisted peritoneal flap vaginoplasty. Journal of Robotic Surgery, 20(1). https://doi.org/10.1007/s11701-025-03041-6
Vancouver
Goldman JR, Yanoshak EC, Kareddy A, Kumar A, Pawly JM, Corbett S, et al. Operative efficiency and safety outcomes: single-port versus multi-port robotic-assisted peritoneal flap vaginoplasty. Journal of Robotic Surgery. 2025;20(1). doi:10.1007/s11701-025-03041-6
BibTeX
@article{Goldman2025,
author = {Goldman, Jennifer R and Yanoshak, Emily C and Kareddy, Abhinav and Kumar, Abhishek and Pawly, Jessica M and Corbett, Sean and Stranix, John T},
title = {Operative efficiency and safety outcomes: single-port versus multi-port robotic-assisted peritoneal flap vaginoplasty},
journal = {Journal of Robotic Surgery},
year = {2025},
volume = {20},
number = {1},
doi = {10.1007/s11701-025-03041-6}
}
EUVIMED