EUVIMEDEUVIMED entdecken
Vergleichsstudie

“Far beyond the shape”: an early head-to-head comparative urodynamic analysis of three contemporary totally intracorporeal robotic orthotopic neobladder techniques

Umberto Anceschi, Salvatore Basile, Daniele Amparore, Fabrizio Di Maida, Riccardo Mastroianni, Sabrina De Cillis, Giulia D'Ippolito, Antonio Andrea Grosso, Gabriele Tuderti, Eleonora Rosato, Rocco Simone Flammia, Luca Lambertini und 7 weitere

Journal of Robotic Surgery · 2025

DOI: 10.1007/s11701-025-02821-4 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Journal of Robotic Surgery, 2025. Verfasst von Umberto Anceschi und 18 weiteren Autor:innen. Beteiligte Einrichtung: Uro-Oncology Program, Department of Urology, IRCCS "Regina Elena" National Cancer Institute, Rome, Italy. umberto.anceschi@gmail.com. Hauptthemen laut MEDLINE: Robotic Surgical Procedures, Urodynamics, Cystectomy, Urinary Reservoirs, Continent. Die Arbeit nennt 30 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The expanding use of totally intracorporeal orthotopic neobladder (ICONB) reconstruction after robot-assisted radical cystectomy has fostered multiple configuration variants, yet robust comparative functional data remain limited. This early head-to-head study aimed to assess whether three contemporary ICONB configurations-Padua Ileal Neobladder, Florence Robotic Intracorporeal Neobladder (FloRIN), and a Y-shaped neobladder-deliver comparable urodynamic and continence outcomes despite anatomical nuances. Three prospectively maintained institutional cystectomy databases were merged. Patients who underwent robot-assisted radical cystectomy with ICONB and completed a standardized early multichannel urodynamic assessment were included. Cystometric capacity, compliance, residual peristaltic activity, leak point pressures, and functional continence (daytime and night-time) were compared across configurations. Functional recovery probabilities were estimated using Kaplan-Meier curves and compared with the log-rank test. Non-parametric tests were applied for other comparisons. A total of 142 patients were analyzed (Padua n = 45, FloRIN n = 49, Y-shaped n = 48). Median cystometric capacity was highest in the Padua configuration (346 mL [IQR 272-400]) versus FloRIN (269 mL [242-305]) and Y-shaped (245 mL [200-290]; p < 0.001). Compliance was most favorable in FloRIN (22 mL/cmH₂O [15-27]) compared to Padua (16 [11-41]) and Y-shaped (12 [10-19]; p = 0.029). Residual peristaltic activity and leak point pressures showed minor differences without functional impact. Daytime continence rates were similar (Padua 80%, FloRIN 83%, Y-shaped 79%; p = 0.40); night-time continence followed the same pattern (65%, 70%, 66%; p = 0.30). Kaplan-Meier curves demonstrated overlapping functional recovery trajectories (daytime p = 0.744; night-time p = 0.122). This early head-to-head comparison suggests that when core reconstructive principles are met, contemporary totally intracorporeal neobladder configurations yield distinct urodynamic profiles but comparable functional outcomes. Future efforts should define clear qualitative and temporal standards for urodynamic monitoring to support consistent functional evaluation as robotic cystectomy adoption expands.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Robotic Surgical ProceduresUrodynamicsCystectomyUrinary Reservoirs, ContinentUrinary BladderUrinary DiversionHumansMaleMiddle AgedAgedFemaleUrinary Bladder Neoplasms

Stichwörter der Autor:innen

Functional outcomesIntracorporeal neobladderOrthotopic urinary diversionRobot-assisted radical cystectomyUrinary continenceUrodynamics

Autor:innen und Institutionen

  • Uro-Oncology Program, Department of Urology, IRCCS "Regina Elena" National Cancer Institute, Rome, Italy. umberto.anceschi@gmail.com.
  • Uro-Oncology Program, Department of Urology, IRCCS "Regina Elena" National Cancer Institute, Rome, Italy.
  • Department of Urology, Fondazione Policlinico Universitario Campus Bio-Medico, Rome, Italy.
  • Department of Urology, San Luigi Gonzaga Hospital, University of Turin, Orbassano, Turin, Italy.
  • Department of Experimental and Clinical Medicine, University of Florence, Florence, Italy.
  • Unit of Urology and Andrology, Careggi University Hospital, Florence, Italy.

Zitieren

APA

Anceschi, U., Basile, S., Amparore, D., Di Maida, F., Mastroianni, R., De Cillis, S., D'Ippolito, G., Grosso, A. A., Tuderti, G., Rosato, E., Flammia, R. S., Lambertini, L., Brassetti, A., Conte, F. L., Finazzi Agrò, E., Fiori, C., Porpiglia, F., Minervini, A., & Simone, G. (2025). “Far beyond the shape”: an early head-to-head comparative urodynamic analysis of three contemporary totally intracorporeal robotic orthotopic neobladder techniques. Journal of Robotic Surgery. https://doi.org/10.1007/s11701-025-02821-4

Vancouver

Anceschi U, Basile S, Amparore D, Di Maida F, Mastroianni R, De Cillis S, et al. “Far beyond the shape”: an early head-to-head comparative urodynamic analysis of three contemporary totally intracorporeal robotic orthotopic neobladder techniques. Journal of Robotic Surgery. 2025. doi:10.1007/s11701-025-02821-4

BibTeX
@article{Anceschi2025,
  author = {Anceschi, Umberto and Basile, Salvatore and Amparore, Daniele and Di Maida, Fabrizio and Mastroianni, Riccardo and De Cillis, Sabrina and D'Ippolito, Giulia and Grosso, Antonio Andrea and Tuderti, Gabriele and Rosato, Eleonora and Flammia, Rocco Simone and Lambertini, Luca and Brassetti, Aldo and Conte, Francesco Lupo and Finazzi Agrò, Enrico and Fiori, Cristian and Porpiglia, Francesco and Minervini, Andrea and Simone, Giuseppe},
  title = {“Far beyond the shape”: an early head-to-head comparative urodynamic analysis of three contemporary totally intracorporeal robotic orthotopic neobladder techniques},
  journal = {Journal of Robotic Surgery},
  year = {2025},
  doi = {10.1007/s11701-025-02821-4}
}
Kostenlos starten →