EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Respiratory-induced liver motion prediction using ECG as surrogate signal

Ana Cordón-Avila, Lobke Stienstra, Ying Wang, Sharath Bhagavatula, Pedro Lopes Da Frota Moreira, Momen Abayazid

International Journal of Computer Assisted Radiology and Surgery · 12.08.2026

DOI: 10.1007/s11548-026-03773-2 ↗

Kurz gefasst

Fachartikel in der Zeitschrift International Journal of Computer Assisted Radiology and Surgery, online erschienen am 12.08.2026. Verfasst von Ana Cordón-Avila und 5 weiteren Autor:innen. Beteiligte Einrichtung: Robotics and Mechatronics, Technical Medicine Centre, Faculty of Electrical Engineering, Mathematics and Computer Science, University of Twente, Ensc…. Die Arbeit nennt 44 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: ITEA.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

This study investigates the use of electrocardiogram (ECG) as a surrogate signal to model the liver’s respiratory-induced motion.

Methods

A learning-based model was trained to predict respiratory-induced liver motion by relying exclusively on ECG data, without requiring additional imaging. A correspondence model based on an encoder–decoder architecture was defined to map internal liver motion from ECG signals. Experimental validation was conducted through a human subject study involving eight participants performing various breathing patterns.

Results

The mean absolute error during normal breathing was 2.83 mm, while the overall error considering all breathing patterns was 4.02 mm with correlation coefficients above 0.90. More than 90% of predictions fell within reported acceptable error margins for needle insertion procedures. The model’s performance reduces when the liver motion increases during deep breathing patterns.

Conclusion

ECG can serve as a reliable noninvasive surrogate for predicting liver motion. This approach offers the advantage of being readily available in clinical settings and can provide accurate guidance for interventional procedures.

Schlagwörter

Stichwörter der Autor:innen

Correspondence modelsElectrocardiogramLiver respiratory-induced motionSurrogate signal

Autor:innen und Institutionen

  • Robotics and Mechatronics, Technical Medicine Centre, Faculty of Electrical Engineering, Mathematics and Computer Science, University of Twente, Enschede, 7500 AE, Netherlands.
  • Department of Biomedical Signals and Systems, University of Twente, Enschede, 7500 AE, Netherlands.
  • Department of Radiology, Brigham and Women's Hospital, Harvard Medical School, 75 Francis St., Boston, MA, 02115, USA.
  • Interdisciplinary Research Center for Bio-Systems and Machines, Control and Instrumentation Engineering Department, King Fahd University of Petroleum and Minerals, P.O. Box 1816, Dhahran, 31261, Kingdom of Saudi Arabia.…

Förderung

  • ITEA

Zitieren

APA

Cordón-Avila, A., Stienstra, L., Wang, Y., Bhagavatula, S., Moreira, P. L. D. F., & Abayazid, M. (2026). Respiratory-induced liver motion prediction using ECG as surrogate signal. International Journal of Computer Assisted Radiology and Surgery. https://doi.org/10.1007/s11548-026-03773-2

Vancouver

Cordón-Avila A, Stienstra L, Wang Y, Bhagavatula S, Moreira PLDF, Abayazid M. Respiratory-induced liver motion prediction using ECG as surrogate signal. International Journal of Computer Assisted Radiology and Surgery. 2026. doi:10.1007/s11548-026-03773-2

BibTeX
@article{CordnAvila2026,
  author = {Cordón-Avila, Ana and Stienstra, Lobke and Wang, Ying and Bhagavatula, Sharath and Moreira, Pedro Lopes Da Frota and Abayazid, Momen},
  title = {Respiratory-induced liver motion prediction using ECG as surrogate signal},
  journal = {International Journal of Computer Assisted Radiology and Surgery},
  year = {2026},
  doi = {10.1007/s11548-026-03773-2}
}
Kostenlos starten →