Fachartikel in der Zeitschrift International Journal of Computer Assisted Radiology and Surgery, 2026. Verfasst von Aure Enkaoua und 5 weiteren Autor:innen. Beteiligte Einrichtung: UCL Hawkes Institute, Department of Medical Physics and Biomedical Engineering, University College London, London, UK. zcemaen@ucl.ac.uk. Hauptthemen laut MEDLINE: Augmented Reality, Imaging, Three-Dimensional, Surgery, Computer-Assisted, Endoscopy. Die Arbeit nennt 10 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: EPSRC Centre for Doctoral Training in Medical Imaging, Wellcome / EPSRC Centre for Interventional and Surgical Sciences, Engineering and Physical Sciences Research Council.
Abstract (Originalsprache)
Purpose
Accurate registration between pre-operative anatomical models and intra-operative endoscopic views is essential for reliable Augmented reality (AR) guidance in pituitary surgery. While coarse alignment can be achieved using external facial reconstruction, it does not account for relative motion between the face and internal surgical targets. Precise alignment at the sella region further remains challenging due to the lack of direct depth information in monocular endoscopy.
Methods
To identify an appropriate similarity metric for registration refinement, we conducted a grid search comparing monocular depth predictions from endoscopic images with depth rendered from a pre-operative 3D model. Normalised cross-correlation (NCC) demonstrated the most robust performance and was selected as the optimisation objective. A continuous optimisation framework was then implemented to iteratively refine translational pose parameters by maximising NCC, with optimisation applied periodically and propagated across frames for computational efficiency.
Results
Depth-based optimisation improved alignment at the surgical target, increasing DICE from 0.77 to 0.81, IoU from 0.63 to 0.68, and reducing centroid localisation error by 36%.
Conclusion
Overall, the proposed depth-based refinement improves target alignment in endoscopic AR guidance and demonstrates the potential of monocular depth cues for intra-operative registration correction.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- UCL Hawkes Institute, Department of Medical Physics and Biomedical Engineering, University College London, London, UK. zcemaen@ucl.ac.uk.
- CEIMM, Universidad Politécnica de Madrid, Madrid, 28031, Spain.
- UCL Hawkes Institute, Department of Medical Physics and Biomedical Engineering, University College London, London, UK.
- Division of Informatics, Imaging and Data Science, UoM, Manchester, UK.
- National Hospital for Neurology and Neurosurgery, London, UK.
Förderung
- EPSRC Centre for Doctoral Training in Medical Imaging
- Wellcome / EPSRC Centre for Interventional and Surgical Sciences
- Engineering and Physical Sciences Research Council
Zitieren
APA
Enkaoua, A., Villa, M., Ramalhinho, J., Hoque, M. I., Marcus, H. J., & Clarkson, M. J. (2026). Depth-based local registration refinement for augmented reality in pituitary surgery. International Journal of Computer Assisted Radiology and Surgery. https://doi.org/10.1007/s11548-026-03705-0
Vancouver
Enkaoua A, Villa M, Ramalhinho J, Hoque MI, Marcus HJ, Clarkson MJ. Depth-based local registration refinement for augmented reality in pituitary surgery. International Journal of Computer Assisted Radiology and Surgery. 2026. doi:10.1007/s11548-026-03705-0
BibTeX
@article{Enkaoua2026,
author = {Enkaoua, Aure and Villa, Manuel and Ramalhinho, João and Hoque, Mobarak I and Marcus, Hani J and Clarkson, Matthew J},
title = {Depth-based local registration refinement for augmented reality in pituitary surgery},
journal = {International Journal of Computer Assisted Radiology and Surgery},
year = {2026},
doi = {10.1007/s11548-026-03705-0}
}
EUVIMED