Vergleichsstudie in der Zeitschrift International Journal of Computer Assisted Radiology and Surgery, 2025. Verfasst von Britta Maria Lohn und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Oral and Maxillofacial Surgery, University Hospital RWTH Aachen, Pauwelsstraße 30, 52074, Aachen, Germany. blohn@ukaachen.de. Hauptthemen laut MEDLINE: Fibula, Printing, Three-Dimensional, Free Tissue Flaps, Mandibular Reconstruction. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 47 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: RWTH Aachen University.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

The free fibular flap (FFF) is a standard procedure for the oral rehabilitation of segmental bone defects in the mandible caused by diseases such as malignant processes, osteonecrosis, or trauma. Digital guides and computer-assisted surgery (CAS) can improve precision and reduce the time and cost of surgery. This study evaluates how different designs of slot cutting guides, guiding heights, and cutting instruments affect surgical accuracy during mandibular reconstruction.

Methods

Ninety model operations in a three-part fibular transplant for mandibular reconstruction were conducted according to digital planning with three guide designs (standard, flange, and anatomical slots), three guide heights (1 mm, 2 mm, 3 mm), and two osteotomy instruments (piezoelectric instrument and saw). The cut segments were digitized using computed tomography and digitally evaluated to assess surgical accuracy.

Results

For vestibular and lingual segment length, the anatomical slot and the flange appear to be the most accurate, with the flange slightly under-contoured vestibularly and the standard slot over-contoured lingually and vestibularly ( p < 0.001). There were only minor differences between the use of saw and piezoelectric instrument for lingual ( p = 0.005) and vestibular ( p < 0.001) length and proximal angle ( p = 0.014). The U-distance after global reconstruction for flanges resulted in a median deviation of 0.0468 mm (IQR 8.15), but was not significant ( p = 0.067).

Conclusion

Anatomical slots and flanges are recommended for osteotomy, with guiding effects relying on both haptic and visual control. Unilateral guided flanges also work accurately at high guidance heights. The results of piezoelectric instrument (PI) and saw showed comparable results in the assessment of individual segments and U-reconstruction in this in vitro study without soft tissue, so that the final decision is left to the expertise of the surgeons.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

FibulaPrinting, Three-DimensionalFree Tissue FlapsMandibular ReconstructionOsteotomySurgery, Computer-AssistedPiezosurgeryBone TransplantationHumansIn Vitro TechniquesTomography, X-Ray ComputedEquipment Design

Stichwörter der Autor:innen

Computer-aided designFibulaMandible/surgeryReconstructive surgical proceduresReproducibility of resultsSurgical instrumentsSurgical planning

Autor:innen und Institutionen

  • Department of Oral and Maxillofacial Surgery, University Hospital RWTH Aachen, Pauwelsstraße 30, 52074, Aachen, Germany. blohn@ukaachen.de.
  • Department of Oral and Maxillofacial Surgery, University Hospital RWTH Aachen, Pauwelsstraße 30, 52074, Aachen, Germany.

Förderung

  • RWTH Aachen University

Zitieren

APA

Lohn, B. M., Raith, S., Ooms, M., Winnand, P., Hölzle, F., & Modabber, A. (2025). Comparison of the accuracy of different slot properties of 3D-printed cutting guides for raising free fibular flaps using saw or piezoelectric instruments: an in vitro study. International Journal of Computer Assisted Radiology and Surgery. https://doi.org/10.1007/s11548-025-03474-2

Vancouver

Lohn BM, Raith S, Ooms M, Winnand P, Hölzle F, Modabber A. Comparison of the accuracy of different slot properties of 3D-printed cutting guides for raising free fibular flaps using saw or piezoelectric instruments: an in vitro study. International Journal of Computer Assisted Radiology and Surgery. 2025. doi:10.1007/s11548-025-03474-2

BibTeX
@article{Lohn2025,
  author = {Lohn, Britta Maria and Raith, Stefan and Ooms, Mark and Winnand, Philipp and Hölzle, Frank and Modabber, Ali},
  title = {Comparison of the accuracy of different slot properties of 3D-printed cutting guides for raising free fibular flaps using saw or piezoelectric instruments: an in vitro study},
  journal = {International Journal of Computer Assisted Radiology and Surgery},
  year = {2025},
  doi = {10.1007/s11548-025-03474-2}
}
Kostenlos starten →