SwinCVS: a unified approach to classifying critical view of safety structures in laparoscopic cholecystectomy
International Journal of Computer Assisted Radiology and Surgery · 11.04.2025 · 20 (6) · 1145-1152
DOI: 10.1007/s11548-025-03354-9 ↗Kurz gefasst
Fachartikel in der Zeitschrift International Journal of Computer Assisted Radiology and Surgery, online erschienen am 11.04.2025. Verfasst von Franciszek M Nowak und 3 weiteren Autor:innen. Beteiligte Einrichtung: UCL Hawkes Institute, Department of Medical Physics and Biomedical Engineering, UCL, London, UK. franciszek.nowak.23@ucl.ac.uk. Hauptthemen laut MEDLINE: Cholecystectomy, Laparoscopic, Patient Safety. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 23 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: EPSRC Centre for Doctoral Training in Intelligent, Integrated Imaging in Healthcare, NIHR Central London Patient Safety Research Collaboration.
Abstract (Originalsprache)
Purpose
Laparoscopic cholecystectomy is one of the most commonly performed surgeries in the UK. Despite its safety, the volume of operations leads to a notable number of complications, with surgical errors often mitigated by the critical view of safety (CVS) technique. However, reliably achieving CVS intraoperatively can be challenging. Current state-of-the-art models for automated CVS evaluation rely on complex, multistage training and semantic segmentation masks, restricting their adaptability and limiting further performance improvements.
Methods
We propose SwinCVS, a spatiotemporal architecture designed for end-to-end training. SwinCVS combines the SwinV2 image encoder with an LSTM for robust CVS classification. We evaluated three different backbones—SwinV2, VMamba, and ResNet50—to assess their ability to encode surgical images. SwinCVS model was evaluated with the end-to-end variant, and with the pretrained variant with performance statistically compared with the current state-of-the-art, SV2LSTG on Endoscapes dataset.
Results
SwinV2 demonstrated as the best encoder achieving +2.07% and +17.72% mAP over VMamba and ResNet50, respectively. SwinCVS trained end-to-end achieves 64.59% mAP and performs on par with SV2LSTG (64.68% mAP, p=0.470), while its pretrained variant achieves 67.45% mAP showing a significant improvement over the current SOTA.
Conclusion
Our proposed solution offers a promising approach for CVS classification, outperforming existing methods and eliminating the need for semantic segmentation masks. Its design supports robust feature extraction and allows for future enhancements through additional tasks that force clinically relevant priors. The results highlight that attention-based architectures like SwinV2 are well suited for surgical image encoding, offering a practical approach for improving automated systems in laparoscopic surgery.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- UCL Hawkes Institute, Department of Medical Physics and Biomedical Engineering, UCL, London, UK. franciszek.nowak.23@ucl.ac.uk.
- UCL Hawkes Institute, Department of Medical Physics and Biomedical Engineering, UCL, London, UK.
- Division of Surgery and Interventional Science, UCL, London, UK.
Förderung
- EPSRC Centre for Doctoral Training in Intelligent, Integrated Imaging in Healthcare
- NIHR Central London Patient Safety Research Collaboration
Zitieren
APA
Nowak, F. M., Mazomenos, E. B., Davidson, B., & Clarkson, M. J. (2025). SwinCVS: a unified approach to classifying critical view of safety structures in laparoscopic cholecystectomy. International Journal of Computer Assisted Radiology and Surgery, 20(6), 1145-1152. https://doi.org/10.1007/s11548-025-03354-9
Vancouver
Nowak FM, Mazomenos EB, Davidson B, Clarkson MJ. SwinCVS: a unified approach to classifying critical view of safety structures in laparoscopic cholecystectomy. International Journal of Computer Assisted Radiology and Surgery. 2025;20(6):1145-1152. doi:10.1007/s11548-025-03354-9
BibTeX
@article{Nowak2025,
author = {Nowak, Franciszek M and Mazomenos, Evangelos B and Davidson, Brian and Clarkson, Matthew J},
title = {SwinCVS: a unified approach to classifying critical view of safety structures in laparoscopic cholecystectomy},
journal = {International Journal of Computer Assisted Radiology and Surgery},
year = {2025},
volume = {20},
number = {6},
pages = {1145--1152},
doi = {10.1007/s11548-025-03354-9}
}