EUVIMEDEUVIMED entdecken
Crossref

Fundamental study on improving the quality of X-ray fluorescence computed tomography images by applying deep image prior to projection images as a pre-denoising method

Sota Kusakari, Kazuki Sato, Yuta Tsushima, Masahiro Matsuoka, Tenta Sasaya, Naoki Sunaguchi, Keisuke Matsubara, Hidekazu Kawashima, Kazuyuki Hyodo, Tetsuya Yuasa, Tsutomu Zeniya

International Journal of Computer Assisted Radiology and Surgery · 2024

DOI: 10.1007/s11548-024-03307-8 ↗

Kurz gefasst

Fachartikel in der Zeitschrift International Journal of Computer Assisted Radiology and Surgery, 2024. Verfasst von Sota Kusakari und 10 weiteren Autor:innen. Beteiligte Einrichtung: Graduate School of Science and Technology, Hirosaki University, Hirosaki, Japan. Hauptthemen laut MEDLINE: Tomography, X-Ray Computed, Imaging, Three-Dimensional, Brain, Image Processing, Computer-Assisted. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 31 Literaturangaben. Gefördert von: JSPS KAKENHI.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: We are developing a three-dimensional X-ray fluorescence computed tomography (3D XFCT) system using non-radioactive-labeled compounds for preclinical studies as a new modality that provides images of biological functions. Improvements in image quality and detection limits are required for the in vivo imaging. The aim of this study was to improve the quality of XFCT images by applying a deep image prior (DIP), which is a type of convolutional neural network, to projection images as a pre-denoising method, and then compare with DIP post-denoising. METHODS: DIP can restore images using only the projection images acquired by XFCT. The projected images were processed with DIP for denoising. Three-dimensional images were reconstructed using the ordered subsets expectation maximization method for XFCT systems with multi-pinhole collimators. To evaluate the effectiveness of DIP pre-denoising, we constructed an XFCT system using synchrotron radiation and performed imaging experiments on a physical phantom and a mouse brain sample. The proposed method was compared with the DIP post-denoising and other denoising methods. RESULTS: The proposed DIP pre-denoising method reduced noise and significantly improved the image quality and was superior to the DIP post-denoising and other methods. The contrast-to-noise ratio improved by 3.7 to 4.6 times with almost no deterioration in spatial resolution, and the detection limit improved from 0.069 to 0.035 mg/mL. There was a strong linear relationship between the iodine concentration and pixel values. Finally, image quality of the mouse brain improved. CONCLUSIONS: Through experiments using phantoms and mouse brains, this study demonstrated that the application of DIP to projection images as a pre-denoising method can significantly improve the image quality and detection limit of 3D XFCT without degrading the spatial resolution. DIP was more effective when applied as pre-denoising than as post-denoising and can contribute to in vivo 3D imaging in the future.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Tomography, X-Ray ComputedImaging, Three-DimensionalBrainImage Processing, Computer-AssistedAnimalsPhantoms, ImagingMiceSignal-To-Noise RatioNeural Networks, Computer

Stichwörter der Autor:innen

Biofunctional imagingDeep image priorDenoisingX-ray fluorescence computed tomography

Autor:innen und Institutionen

  • Graduate School of Science and Technology, Hirosaki University, Hirosaki, Japan.
  • Graduate School of Science and Engineering, Yamagata University, Yonezawa, Japan.
  • Department of Radiological and Medical Laboratory Science, Nagoya University Graduate School of Medicine, Nagoya, Japan.
  • Department of Management Science and Engineering, Faculty of Systems Science and Technology, Akita Prefectural University, Yurihonjo, Japan.
  • Radioisotope Research Center, Kyoto Pharmaceutical University, Kyoto, Japan.
  • High Energy Accelerator Research Organization, Tsukuba, Japan.

Förderung

  • JSPS KAKENHI

Zitieren

APA

Kusakari, S., Sato, K., Tsushima, Y., Matsuoka, M., Sasaya, T., Sunaguchi, N., Matsubara, K., Kawashima, H., Hyodo, K., Yuasa, T., & Zeniya, T. (2024). Fundamental study on improving the quality of X-ray fluorescence computed tomography images by applying deep image prior to projection images as a pre-denoising method. International Journal of Computer Assisted Radiology and Surgery. https://doi.org/10.1007/s11548-024-03307-8

Vancouver

Kusakari S, Sato K, Tsushima Y, Matsuoka M, Sasaya T, Sunaguchi N, et al. Fundamental study on improving the quality of X-ray fluorescence computed tomography images by applying deep image prior to projection images as a pre-denoising method. International Journal of Computer Assisted Radiology and Surgery. 2024. doi:10.1007/s11548-024-03307-8

BibTeX
@article{Kusakari2024,
  author = {Kusakari, Sota and Sato, Kazuki and Tsushima, Yuta and Matsuoka, Masahiro and Sasaya, Tenta and Sunaguchi, Naoki and Matsubara, Keisuke and Kawashima, Hidekazu and Hyodo, Kazuyuki and Yuasa, Tetsuya and Zeniya, Tsutomu},
  title = {Fundamental study on improving the quality of X-ray fluorescence computed tomography images by applying deep image prior to projection images as a pre-denoising method},
  journal = {International Journal of Computer Assisted Radiology and Surgery},
  year = {2024},
  doi = {10.1007/s11548-024-03307-8}
}
Kostenlos starten →