Fronto-orbital advancement with patient-specific 3D-printed implants and robot-guided laser osteotomy: an in vitro accuracy assessment
International Journal of Computer Assisted Radiology and Surgery · 2024
DOI: 10.1007/s11548-024-03298-6 ↗Kurz gefasst
Fachartikel in der Zeitschrift International Journal of Computer Assisted Radiology and Surgery, 2024. Verfasst von Michaela Maintz und 10 weiteren Autor:innen. Beteiligte Einrichtung: Medical Additive Manufacturing Research Group (Swiss MAM), Department of Biomedical Engineering, University of Basel, Allschwil, Switzerland. Hauptthemen laut MEDLINE: Printing, Three-Dimensional, Osteotomy, Craniosynostoses, Surgery, Computer-Assisted. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Innovation Focus Regenerative Surgery - University Hospital Basel, Innovation Focus Pediatric Neurosurgery - University Hospital Basel, Werner Siemens-Stiftung.
Abstract (Originalsprache)
Purpose
The use of computer-assisted virtual surgical planning (VSP) for craniosynostosis surgery is gaining increasing implementation in the clinics. However, accurately transferring the preoperative planning data to the operating room remains challenging. We introduced and investigated a fully digital workflow to perform fronto-orbital advancement (FOA) surgery using 3D-printed patient-specific implants (PSIs) and cold-ablation robot-guided laser osteotomy. This novel approach eliminates the need for traditional surgical templates while enhancing precision and customization, offering a more streamlined and efficient surgical process.
Methods
Computed tomography data of a patient with craniosynostosis were used to digitally reconstruct the skull and to perform VSP of the FOA. In total, six PSIs per skull were 3D-printed with a medical-grade bioresorbable composite using the Arburg Plastic Freeforming technology. The planned osteotomy paths and the screw holes, including their positions and axis angles, were digitally transferred to the cold-ablation robot-guided osteotome interface. The osteotomies were performed on 3D-printed patient skull models. The implants, osteotomy and final FOA results were scanned and compared to the VSP data.
Results
The osteotomy deviations for the skulls indicated an overall maximum distance of 1.7 mm, a median deviation of 0.44 mm, and a maximum root mean square (RMS) error of 0.67 mm. The deviation of the point-to-point surface comparison of the FOA with the VSP data resulted in a median accuracy of 1.27 mm. Accessing the orbital cavity with the laser remained challenging.
Conclusion
This in vitro study showcases a novel FOA technique by effectively combining robot-guided laser osteotomy with 3D-printed patient-specific implants, eliminating the need for surgical templates and achieving high accuracy in bone cutting and positioning. The workflow holds promise for reducing preoperative planning time and increasing surgical efficiency. Further studies on bone tissue are required to validate the safety and effectiveness of this approach, especially in addressing the challenges of pediatric craniofacial surgery.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Medical Additive Manufacturing Research Group (Swiss MAM), Department of Biomedical Engineering, University of Basel, Allschwil, Switzerland.
- Institute for Medical Engineering and Medical Informatics, University of Applied Sciences and Arts Northwestern Switzerland, Muttenz, Switzerland.
- Clinic Oral and Cranio-Maxillofacial Surgery, University Hospital Basel, Basel, Switzerland.
- Medical Additive Manufacturing Research Group (Swiss MAM), Department of Biomedical Engineering, University of Basel, Allschwil, Switzerland. neha.sharma@unibas.ch.
- Clinic Oral and Cranio-Maxillofacial Surgery, University Hospital Basel, Basel, Switzerland. neha.sharma@unibas.ch.
- Hand- and Peripheral Nerve Surgery, Department of Orthopaedic Surgery and Traumatology, Kantonsspital Baselland, Bruderholz Liestal Laufen, Switzerland.
Förderung
- Innovation Focus Regenerative Surgery - University Hospital Basel
- Innovation Focus Pediatric Neurosurgery - University Hospital Basel
- Werner Siemens-Stiftung
- University of Basel
Zitieren
APA
Maintz, M., Desan, N., Sharma, N., Beinemann, J., Beyer, M., Seiler, D., Honigmann, P., Soleman, J., Guzman, R., Cattin, P. C., & Thieringer, F. M. (2024). Fronto-orbital advancement with patient-specific 3D-printed implants and robot-guided laser osteotomy: an in vitro accuracy assessment. International Journal of Computer Assisted Radiology and Surgery. https://doi.org/10.1007/s11548-024-03298-6
Vancouver
Maintz M, Desan N, Sharma N, Beinemann J, Beyer M, Seiler D, et al. Fronto-orbital advancement with patient-specific 3D-printed implants and robot-guided laser osteotomy: an in vitro accuracy assessment. International Journal of Computer Assisted Radiology and Surgery. 2024. doi:10.1007/s11548-024-03298-6
BibTeX
@article{Maintz2024,
author = {Maintz, Michaela and Desan, Nora and Sharma, Neha and Beinemann, Jörg and Beyer, Michel and Seiler, Daniel and Honigmann, Philipp and Soleman, Jehuda and Guzman, Raphael and Cattin, Philippe C and Thieringer, Florian M},
title = {Fronto-orbital advancement with patient-specific 3D-printed implants and robot-guided laser osteotomy: an in vitro accuracy assessment},
journal = {International Journal of Computer Assisted Radiology and Surgery},
year = {2024},
doi = {10.1007/s11548-024-03298-6}
}
EUVIMED