Global registration of kidneys in 3D ultrasound and CT images
International Journal of Computer Assisted Radiology and Surgery · 06.09.2024 · 20 (1) · 65-75
DOI: 10.1007/s11548-024-03255-3 ↗Kurz gefasst
Fachartikel in der Zeitschrift International Journal of Computer Assisted Radiology and Surgery, online erschienen am 06.09.2024. Verfasst von William Ndzimbong und 8 weiteren Autor:innen. Beteiligte Einrichtung: CNRS, ICUBE Laboratory, University of Strasbourg, Strasbourg, France. william.ndzimbong@ircad.fr. Hauptthemen laut MEDLINE: Tomography, X-Ray Computed, Imaging, Three-Dimensional, Kidney. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 29 Literaturangaben. Gefördert von: Conseil régional du Grand Est.
Abstract (Originalsprache)
PURPOSE: Automatic registration between abdominal ultrasound (US) and computed tomography (CT) images is needed to enhance interventional guidance of renal procedures, but it remains an open research challenge. We propose a novel method that doesn't require an initial registration estimate (a global method) and also handles registration ambiguity caused by the organ's natural symmetry. Combined with a registration refinement algorithm, this method achieves robust and accurate kidney registration while avoiding manual initialization. METHODS: We propose solving global registration in a three-step approach: (1) Automatic anatomical landmark localization, where 2 deep neural networks (DNNs) localize a set of landmarks in each modality. (2) Registration hypothesis generation, where potential registrations are computed from the landmarks with a deterministic variant of RANSAC. Due to the Kidney's strong bilateral symmetry, there are usually 2 compatible solutions. Finally, in Step (3), the correct solution is determined automatically, using a DNN classifier that resolves the geometric ambiguity. The registration may then be iteratively improved with a registration refinement method. Results are presented with state-of-the-art surface-based refinement-Bayesian coherent point drift (BCPD). RESULTS: This automatic global registration approach gives better results than various competitive state-of-the-art methods, which, additionally, require organ segmentation. The results obtained on 59 pairs of 3D US/CT kidney images show that the proposed method, combined with BCPD refinement, achieves a target registration error (TRE) of an internal kidney landmark (the renal pelvis) of 5.78 mm and an average nearest neighbor surface distance (nndist) of 2.42 mm. CONCLUSION: This work presents the first approach for automatic kidney registration in US and CT images, which doesn't require an initial manual registration estimate to be known a priori. The results show a fully automatic registration approach with performances comparable to manual methods is feasible.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- CNRS, ICUBE Laboratory, University of Strasbourg, Strasbourg, France. william.ndzimbong@ircad.fr.
- Research Institute against Digestive Cancer (IRCAD), Kigali, Rwanda. william.ndzimbong@ircad.fr.
- CNRS, ISIR, Sorbonne University, Paris, France.
- Department of Urology, HEGP, APHP, Paris, France.
- Research Institute against Digestive Cancer (IRCAD), Kigali, Rwanda.
- Medical Imaging Group MIM, Clinique Sainte Anne, Strasbourg, France.
Förderung
- Conseil régional du Grand Est
Zitieren
APA
Ndzimbong, W., Thome, N., Fourniol, C., Keeza, Y., Sauer, B., Marescaux, J., George, D., Hostettler, A., & Collins, T. (2024). Global registration of kidneys in 3D ultrasound and CT images. International Journal of Computer Assisted Radiology and Surgery, 20(1), 65-75. https://doi.org/10.1007/s11548-024-03255-3
Vancouver
Ndzimbong W, Thome N, Fourniol C, Keeza Y, Sauer B, Marescaux J, et al. Global registration of kidneys in 3D ultrasound and CT images. International Journal of Computer Assisted Radiology and Surgery. 2024;20(1):65-75. doi:10.1007/s11548-024-03255-3
BibTeX
@article{Ndzimbong2024,
author = {Ndzimbong, William and Thome, Nicolas and Fourniol, Cyril and Keeza, Yvonne and Sauer, Benoît and Marescaux, Jacques and George, Daniel and Hostettler, Alexandre and Collins, Toby},
title = {Global registration of kidneys in 3D ultrasound and CT images},
journal = {International Journal of Computer Assisted Radiology and Surgery},
year = {2024},
volume = {20},
number = {1},
pages = {65--75},
doi = {10.1007/s11548-024-03255-3}
}
EUVIMED