A novel contact optimization algorithm for endomicroscopic surface scanning
International Journal of Computer Assisted Radiology and Surgery · 2024
DOI: 10.1007/s11548-024-03223-x ↗Kurz gefasst
Fachartikel in der Zeitschrift International Journal of Computer Assisted Radiology and Surgery, 2024. Verfasst von Xingfeng Xu und 3 weiteren Autor:innen. Beteiligte Einrichtung: Key Laboratory of Mechanism Theory and Equipment Design of Ministry of Education, Tianjin University, Tianjin, 300072, China. Hauptthemen laut MEDLINE: Algorithms, Microscopy, Confocal. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 25 Literaturangaben. Gefördert von: National Natural Science Foundation of China.
Abstract (Originalsprache)
PURPOSE: Probe-based confocal laser endomicroscopy (pCLE) offers real-time, cell-level imaging and holds promise for early cancer diagnosis. However, a large area surface scanning for image acquisition is needed to overcome the limitation of field-of-view. Obtaining high-quality images during scanning requires maintaining a stable contact distance between the tissue and probe. This work presents a novel contact optimization algorithm to acquire high-quality pCLE images. METHODS: The contact optimization algorithm, based on swarm intelligence of whale optimization algorithm, is designed to optimize the probe position, according to the quality of the image acquired by probe. An accurate image quality assessment of total co-occurrence entropy is introduced to evaluate the pCLE image quality. The algorithm aims to maintain a consistent probe-tissue contact, resulting in high-quality images acquisition. RESULTS: Scanning experiments on sponge, ex vivo swine skin tissue and stomach tissue demonstrate the effectiveness of the contact optimization algorithm. Scanning results of the sponge with three different trajectories (spiral trajectory, circle trajectory, and raster trajectory) reveal high-quality mosaics with clear details in every part of the image and no blurred sections. CONCLUSION: The contact optimization algorithm successfully identifies the optimal distance between probe and tissue, improving the quality of pCLE images. Experimental results confirm the high potential of this method in endomicroscopic surface scanning.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Key Laboratory of Mechanism Theory and Equipment Design of Ministry of Education, Tianjin University, Tianjin, 300072, China.
- Key Laboratory of Mechanism Theory and Equipment Design of Ministry of Education, Tianjin University, Tianjin, 300072, China. siyang_zuo@tju.edu.cn.
Förderung
- National Natural Science Foundation of China
Zitieren
APA
Xu, X., Zhao, S., Gong, L., & Zuo, S. (2024). A novel contact optimization algorithm for endomicroscopic surface scanning. International Journal of Computer Assisted Radiology and Surgery. https://doi.org/10.1007/s11548-024-03223-x
Vancouver
Xu X, Zhao S, Gong L, Zuo S. A novel contact optimization algorithm for endomicroscopic surface scanning. International Journal of Computer Assisted Radiology and Surgery. 2024. doi:10.1007/s11548-024-03223-x
BibTeX
@article{Xu2024,
author = {Xu, Xingfeng and Zhao, Shengzhe and Gong, Lun and Zuo, Siyang},
title = {A novel contact optimization algorithm for endomicroscopic surface scanning},
journal = {International Journal of Computer Assisted Radiology and Surgery},
year = {2024},
doi = {10.1007/s11548-024-03223-x}
}
EUVIMED