Surgical-DeSAM: decoupling SAM for instrument segmentation in robotic surgery
International Journal of Computer Assisted Radiology and Surgery · 2024
DOI: 10.1007/s11548-024-03163-6 ↗Kurz gefasst
Fachartikel in der Zeitschrift International Journal of Computer Assisted Radiology and Surgery, 2024. Verfasst von Yuyang Sheng und 3 weiteren Autor:innen. Beteiligte Einrichtung: Wellcome/EPSRC Centre for Interventional and Surgical Sciences (WEISS), University College London, London, UK. Hauptthemen laut MEDLINE: Robotic Surgical Procedures. Die Arbeit wurde bisher 30-mal zitiert (Crossref) und nennt 15 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Engineering and Physical Sciences Research Council.
Abstract (Originalsprache)
Purpose
The recent segment anything model (SAM) has demonstrated impressive performance with point, text or bounding box prompts, in various applications. However, in safety-critical surgical tasks, prompting is not possible due to (1) the lack of per-frame prompts for supervised learning, (2) it is unrealistic to prompt frame-by-frame in a real-time tracking application, and (3) it is expensive to annotate prompts for offline applications.
Methods
We develop Surgical-DeSAM to generate automatic bounding box prompts for decoupling SAM to obtain instrument segmentation in real-time robotic surgery. We utilise a commonly used detection architecture, DETR, and fine-tuned it to obtain bounding box prompt for the instruments. We then empolyed decoupling SAM (DeSAM) by replacing the image encoder with DETR encoder and fine-tune prompt encoder and mask decoder to obtain instance segmentation for the surgical instruments. To improve detection performance, we adopted the Swin-transformer to better feature representation.
Results
The proposed method has been validated on two publicly available datasets from the MICCAI surgical instruments segmentation challenge EndoVis 2017 and 2018. The performance of our method is also compared with SOTA instrument segmentation methods and demonstrated significant improvements with dice metrics of 89.62 and 90.70 for the EndoVis 2017 and 2018 Conclusion Our extensive experiments and validations demonstrate that Surgical-DeSAM enables real-time instrument segmentation without any additional prompting and outperforms other SOTA segmentation methods
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Wellcome/EPSRC Centre for Interventional and Surgical Sciences (WEISS), University College London, London, UK.
- Department of Computer Science, University College London, London, UK.
- Department of Medical Physics and Biomedical Engineering, University College London, London, UK.
- Wellcome/EPSRC Centre for Interventional and Surgical Sciences (WEISS), University College London, London, UK. mobarakol.islam@ucl.ac.uk.
- Department of Medical Physics and Biomedical Engineering, University College London, London, UK. mobarakol.islam@ucl.ac.uk.
Förderung
- Engineering and Physical Sciences Research Council
Zitieren
APA
Sheng, Y., Bano, S., Clarkson, M. J., & Islam, M. (2024). Surgical-DeSAM: decoupling SAM for instrument segmentation in robotic surgery. International Journal of Computer Assisted Radiology and Surgery. https://doi.org/10.1007/s11548-024-03163-6
Vancouver
Sheng Y, Bano S, Clarkson MJ, Islam M. Surgical-DeSAM: decoupling SAM for instrument segmentation in robotic surgery. International Journal of Computer Assisted Radiology and Surgery. 2024. doi:10.1007/s11548-024-03163-6
BibTeX
@article{Sheng2024,
author = {Sheng, Yuyang and Bano, Sophia and Clarkson, Matthew J and Islam, Mobarakol},
title = {Surgical-DeSAM: decoupling SAM for instrument segmentation in robotic surgery},
journal = {International Journal of Computer Assisted Radiology and Surgery},
year = {2024},
doi = {10.1007/s11548-024-03163-6}
}
EUVIMED