Smart goggles augmented reality CT–US fusion compared to conventional fusion navigation for percutaneous needle insertion
International Journal of Computer Assisted Radiology and Surgery · 2024
DOI: 10.1007/s11548-024-03148-5 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift International Journal of Computer Assisted Radiology and Surgery, 2024. Verfasst von Tabea Borde und 13 weiteren Autor:innen. Beteiligte Einrichtung: Center for Interventional Oncology, Radiology and Imaging Sciences, Clinical Center, National Institutes of Health, 10 Center Drive, Room 3N320, MSC …. Hauptthemen laut MEDLINE: Augmented Reality, Tomography, X-Ray Computed, Ultrasonography, Interventional, Smart Glasses. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 23 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NCI NIH HHS, NIH Clinical Center, National Cancer Institute.
Abstract (Originalsprache)
Purpose
Targeting accuracy determines outcomes for percutaneous needle interventions. Augmented reality (AR) in IR may improve procedural guidance and facilitate access to complex locations. This study aimed to evaluate percutaneous needle placement accuracy using a goggle-based AR system compared to an ultrasound (US)-based fusion navigation system.
Methods
Six interventional radiologists performed 24 independent needle placements in an anthropomorphic phantom (CIRS 057A) in four needle guidance cohorts ( n = 6 each): (1) US-based fusion, (2) goggle-based AR with stereoscopically projected anatomy (AR-overlay), (3) goggle AR without the projection (AR-plain), and (4) CT-guided freehand. US-based fusion included US/CT registration with electromagnetic (EM) needle, transducer, and patient tracking. For AR-overlay, US, EM-tracked needle, stereoscopic anatomical structures and targets were superimposed over the phantom. Needle placement accuracy (distance from needle tip to target center), placement time (from skin puncture to final position), and procedure time (time to completion) were measured.
Results
Mean needle placement accuracy using US-based fusion, AR-overlay, AR-plain, and freehand was 4.5 ± 1.7 mm, 7.0 ± 4.7 mm, 4.7 ± 1.7 mm, and 9.2 ± 5.8 mm, respectively. AR-plain demonstrated comparable accuracy to US-based fusion ( p = 0.7) and AR-overlay ( p = 0.06). Excluding two outliers, AR-overlay accuracy became 5.9 ± 2.6 mm. US-based fusion had the highest mean placement time (44.3 ± 27.7 s) compared to all navigation cohorts ( p < 0.001). Longest procedure times were recorded with AR-overlay (34 ± 10.2 min) compared to AR-plain (22.7 ± 8.6 min, p = 0.09), US-based fusion (19.5 ± 5.6 min, p = 0.02), and freehand (14.8 ± 1.6 min, p = 0.002).
Conclusion
Goggle-based AR showed no difference in needle placement accuracy compared to the commercially available US-based fusion navigation platform. Differences in accuracy and procedure times were apparent with different display modes (with/without stereoscopic projections). The AR-based projection of the US and needle trajectory over the body may be a helpful tool to enhance visuospatial orientation. Thus, this study refines the potential role of AR for needle placements, which may serve as a catalyst for informed implementation of AR techniques in IR.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Center for Interventional Oncology, Radiology and Imaging Sciences, Clinical Center, National Institutes of Health, 10 Center Drive, Room 3N320, MSC 1182, Bethesda, MD, 20892, USA. tabea.borde@nih.gov.
- Center for Interventional Oncology, Radiology and Imaging Sciences, Clinical Center, National Institutes of Health, 10 Center Drive, Room 3N320, MSC 1182, Bethesda, MD, 20892, USA.
- Henri Mondor Biomedical Research Institute, Inserm U955, Team N°18, Créteil, France.
- Philips Healthcare, Cambridge, MA, 02141, USA.
- Department of Radiology, Georgetown Medical School, Medstar Washington Hospital Center, Washington, DC, 20007, USA.
- Fischell Department of Bioengineering, University of Maryland, College Park, MD, 20742, USA.
Förderung
- NCI NIH HHS
- NIH Clinical Center
- National Cancer Institute
- National Institutes of Health
Zitieren
APA
Borde, T., Saccenti, L., Li, M., Varble, N. A., Hazen, L. A., Kassin, M. T., Ukeh, I. N., Horton, K. M., Delgado, J. F., Martin, C., Xu, S., Pritchard, W. F., Karanian, J. W., & Wood, B. J. (2024). Smart goggles augmented reality CT–US fusion compared to conventional fusion navigation for percutaneous needle insertion. International Journal of Computer Assisted Radiology and Surgery. https://doi.org/10.1007/s11548-024-03148-5
Vancouver
Borde T, Saccenti L, Li M, Varble NA, Hazen LA, Kassin MT, et al. Smart goggles augmented reality CT–US fusion compared to conventional fusion navigation for percutaneous needle insertion. International Journal of Computer Assisted Radiology and Surgery. 2024. doi:10.1007/s11548-024-03148-5
BibTeX
@article{Borde2024,
author = {Borde, Tabea and Saccenti, Laetitia and Li, Ming and Varble, Nicole A and Hazen, Lindsey A and Kassin, Michael T and Ukeh, Ifechi N and Horton, Keith M and Delgado, Jose F and Martin, Charles and Xu, Sheng and Pritchard, William F and Karanian, John W and Wood, Bradford J},
title = {Smart goggles augmented reality CT–US fusion compared to conventional fusion navigation for percutaneous needle insertion},
journal = {International Journal of Computer Assisted Radiology and Surgery},
year = {2024},
doi = {10.1007/s11548-024-03148-5}
}
EUVIMED