Noctopus: a novel device and method for patient registration and navigation in image-guided cranial surgery

Yusuf Özbek, Zoltán Bárdosi, Wolfgang Freysinger

International Journal of Computer Assisted Radiology and Surgery · 2024

DOI: 10.1007/s11548-024-03135-w ↗

Kurz gefasst

Fachartikel in der Zeitschrift International Journal of Computer Assisted Radiology and Surgery, 2024. Verfasst von Yusuf Özbek und 2 weiteren Autor:innen. Beteiligte Einrichtung: Medical University of Innsbruck, University ENT Clinic, Innsbruck, Austria. yusuf.ozbek.phd@gmail.com. Hauptthemen laut MEDLINE: Surgery, Computer-Assisted, Fiducial Markers, Phantoms, Imaging. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Medizinische Universität Innsbruck, Bundesministerium für Klimaschutz, Umwelt, Energie, Mobilität, Innovation und Technologie.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

A patient registration and real-time surgical navigation system and a novel device and method (Noctopus) is presented. With any tracking system technology and a patient/target-specific registration marker configuration, submillimetric target registration error (TRE), high-precise application accuracy for single or multiple anatomical targets in image-guided neurosurgery or ENT surgery is realized.

Methods

The system utilizes the advantages of marker-based registration technique and allows to perform automatized patient registration using on the device attached and with patient scanned four fiducial markers. The best possible sensor/marker positions around the patient’s head are determined for single or multiple region(s) of interest (target/s) in the anatomy. Once brought at the predetermined positions the device can be operated with any tracking system for registration purposes.

Results

Targeting accuracy was evaluated quantitatively at various target positions on a phantom skull. The target registration error (TRE) was measured on individual targets using an electromagnetic tracking system. The overall averaged TRE was 0.22 ± 0.08 mm for intraoperative measurements.

Conclusion

An automatized patient registration system using optimized patient-/target-specific marker configurations is proposed. High-precision and user-error-free intraoperative surgical navigation with minimum number of registration markers and sensors is realized. The targeting accuracy is significantly improved in minimally invasive neurosurgical and ENT interventions.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Surgery, Computer-AssistedFiducial MarkersPhantoms, ImagingHumansEquipment DesignTomography, X-Ray ComputedNeurosurgical ProceduresSurgical Navigation SystemsNeuronavigationSkull

Stichwörter der Autor:innen

Fiducial configurationMagnetic trackingOptical trackingPatient registrationSurgical navigation

Autor:innen und Institutionen

  • Medical University of Innsbruck, University ENT Clinic, Innsbruck, Austria. yusuf.ozbek.phd@gmail.com.
  • Medical University of Innsbruck, University ENT Clinic, Innsbruck, Austria.

Förderung

  • Medizinische Universität Innsbruck
  • Bundesministerium für Klimaschutz, Umwelt, Energie, Mobilität, Innovation und Technologie

Zitieren

APA

Özbek, Y., Bárdosi, Z., & Freysinger, W. (2024). Noctopus: a novel device and method for patient registration and navigation in image-guided cranial surgery. International Journal of Computer Assisted Radiology and Surgery. https://doi.org/10.1007/s11548-024-03135-w

Vancouver

Özbek Y, Bárdosi Z, Freysinger W. Noctopus: a novel device and method for patient registration and navigation in image-guided cranial surgery. International Journal of Computer Assisted Radiology and Surgery. 2024. doi:10.1007/s11548-024-03135-w

BibTeX
@article{zbek2024,
  author = {Özbek, Yusuf and Bárdosi, Zoltán and Freysinger, Wolfgang},
  title = {Noctopus: a novel device and method for patient registration and navigation in image-guided cranial surgery},
  journal = {International Journal of Computer Assisted Radiology and Surgery},
  year = {2024},
  doi = {10.1007/s11548-024-03135-w}
}