Path tracking control of a steerable catheter in transcatheter cardiology interventions
International Journal of Computer Assisted Radiology and Surgery · 22.02.2024 · 19 (4) · 757-766
DOI: 10.1007/s11548-024-03069-3 ↗Kurz gefasst
Fachartikel in der Zeitschrift International Journal of Computer Assisted Radiology and Surgery, online erschienen am 22.02.2024. Verfasst von Xiu Zhang und 12 weiteren Autor:innen. Beteiligte Einrichtung: Department of Electronics, Information and Bioengineering, Politecnico di Milano, 20133, Milan, Italy. xiu.zhang@polimi.it. Hauptthemen laut MEDLINE: Robotics, Mitral Valve Insufficiency, Cardiology. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 39 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: H2020 European Research Council.
Abstract (Originalsprache)
Purpose
Intracardiac transcatheter interventions allow for reducing trauma and hospitalization stays as compared to standard surgery. In the treatment of mitral regurgitation, the most widely adopted transcatheter approach consists in deploying a clip on the mitral valve leaflets by means of a catheter that is run through veins from a peripheral access to the left atrium. However, precise manipulation of the catheter from outside the body while copying with the path constraints imposed by the vessels remains challenging.
Methods
We proposed a path tracking control framework that provides adequate motion commands to the robotic steerable catheter for autonomous navigation through vascular lumens. The proposed work implements a catheter kinematic model featuring nonholonomic constraints. Relying on the real-time measurements from an electromagnetic sensor and a fiber Bragg grating sensor, a two-level feedback controller was designed to control the catheter.
Results
The proposed method was tested in a patient-specific vessel phantom. A median position error between the center line of the vessel and the catheter tip trajectory was found to be below 2 mm, with a maximum error below 3 mm. Statistical testing confirmed that the performance of the proposed method exhibited no significant difference in both free space and the contact region.
Conclusion
The preliminary in vitro studies presented in this paper showed promising accuracy in navigating the catheter within the vessel. The proposed approach enables autonomous control of a steerable catheter for transcatheter cardiology interventions without the request of calibrating the intuitive parameters or acquiring a training dataset.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Electronics, Information and Bioengineering, Politecnico di Milano, 20133, Milan, Italy. xiu.zhang@polimi.it.
- Department of Mechanical Engineering, KU Leuven, 3001, Leuven, Belgium.
- Department of Electronics, Information and Bioengineering, Politecnico di Milano, 20133, Milan, Italy.
Förderung
- H2020 European Research Council
Zitieren
APA
Zhang, X., Sridhar, A., Ha, X. T., Mehdi, S. Z., Fortuna, A., Magro, M., Peloso, A., Bicchi, A., Ourak, M., Aliverti, A., Votta, E., Vander Poorten, E., & De Momi, E. (2024). Path tracking control of a steerable catheter in transcatheter cardiology interventions. International Journal of Computer Assisted Radiology and Surgery, 19(4), 757-766. https://doi.org/10.1007/s11548-024-03069-3
Vancouver
Zhang X, Sridhar A, Ha XT, Mehdi SZ, Fortuna A, Magro M, et al. Path tracking control of a steerable catheter in transcatheter cardiology interventions. International Journal of Computer Assisted Radiology and Surgery. 2024;19(4):757-766. doi:10.1007/s11548-024-03069-3
BibTeX
@article{Zhang2024,
author = {Zhang, Xiu and Sridhar, Aditya and Ha, Xuan Thao and Mehdi, Syed Zain and Fortuna, Andrea and Magro, Mattia and Peloso, Angela and Bicchi, Anna and Ourak, Mouloud and Aliverti, Andrea and Votta, Emiliano and Vander Poorten, Emmanuel and De Momi, Elena},
title = {Path tracking control of a steerable catheter in transcatheter cardiology interventions},
journal = {International Journal of Computer Assisted Radiology and Surgery},
year = {2024},
volume = {19},
number = {4},
pages = {757--766},
doi = {10.1007/s11548-024-03069-3}
}
EUVIMED