Thickness and design features of clinical cranial implants—what should automated methods strive to replicate?

Z Fishman, James G Mainprize, Glenn Edwards, Oleh Antonyshyn, Michael Hardisty, C M Whyne

International Journal of Computer Assisted Radiology and Surgery · 2024

DOI: 10.1007/s11548-024-03068-4 ↗

Kurz gefasst

Fachartikel in der Zeitschrift International Journal of Computer Assisted Radiology and Surgery, 2024. Verfasst von Z Fishman und 5 weiteren Autor:innen. Beteiligte Einrichtung: Orthopaedic Biomechanics Laboratory, Sunnybrook Research Institute, Toronto, ON, Canada. zachary.fishman@sri.utoronto.ca. Hauptthemen laut MEDLINE: Skull, Plastic Surgery Procedures. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 24 Literaturangaben. Gefördert von: Natural Sciences and Engineering Research Council of Canada, INOVAIT, Canadian Institutes of Health Research (CIHR).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: New deep learning and statistical shape modelling approaches aim to automate the design process for patient-specific cranial implants, as highlighted by the MICCAI AutoImplant Challenges. To ensure applicability, it is important to determine if the training data used in developing these algorithms represent the geometry of implants designed for clinical use. METHODS: Calavera Surgical Design provided a dataset of 206 post-craniectomy skull geometries and their clinically used implants. The MUG500+ dataset includes 29 post-craniectomy skull geometries and implants designed for automating design. For both implant and skull shapes, the inner and outer cortical surfaces were segmented, and the thickness between them was measured. For the implants, a 'rim' was defined that transitions from the repaired defect to the surrounding skull. For unilateral defect cases, skull implants were mirrored to the contra-lateral side and thickness differences were quantified. RESULTS: The average thickness of the clinically used implants was 6.0 ± 0.5 mm, which approximates the thickness on the contra-lateral side of the skull (relative difference of -0.3 ± 1.4 mm). The average thickness of the MUG500+ implants was 2.9 ± 1.0 mm, significantly thinner than the intact skull thickness (relative difference of 2.9 ± 1.2 mm). Rim transitions in the clinical implants (average width of 8.3 ± 3.4 mm) were used to cap and create a smooth boundary with the skull. CONCLUSIONS: For implant modelers or manufacturers, this shape analysis quantified differences of cranial implants (thickness, rim width, surface area, and volume) to help guide future automated design algorithms. After skull completion, a thicker implant can be more versatile for cases involving muscle hollowing or thin skulls, and wider rims can smooth over the defect margins to provide more stability. For clinicians, the differing measurements and implant designs can help inform the options available for their patient specific treatment.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

SkullPlastic Surgery ProceduresHumansProsthesis DesignProstheses and ImplantsCraniotomyHead

Stichwörter der Autor:innen

Automated designCraniectomyCraniotomySkull implantsThickness measurementsTraining data sets

Autor:innen und Institutionen

  • Orthopaedic Biomechanics Laboratory, Sunnybrook Research Institute, Toronto, ON, Canada. zachary.fishman@sri.utoronto.ca.
  • Calavera Surgical Design Inc., Toronto, ON, Canada.
  • Division of Plastic Surgery, Sunnybrook Health Sciences Centre, Toronto, ON, Canada.
  • Orthopaedic Biomechanics Laboratory, Sunnybrook Research Institute, Toronto, ON, Canada.
  • Department of Surgery, University of Toronto, Toronto, ON, Canada.
  • Institute of Biomedical Engineering, University of Toronto, Toronto, ON, Canada.

Förderung

  • Natural Sciences and Engineering Research Council of Canada
  • INOVAIT
  • Canadian Institutes of Health Research (CIHR)

Zitieren

APA

Fishman, Z., Mainprize, J. G., Edwards, G., Antonyshyn, O., Hardisty, M., & Whyne, C. M. (2024). Thickness and design features of clinical cranial implants—what should automated methods strive to replicate?. International Journal of Computer Assisted Radiology and Surgery. https://doi.org/10.1007/s11548-024-03068-4

Vancouver

Fishman Z, Mainprize JG, Edwards G, Antonyshyn O, Hardisty M, Whyne CM. Thickness and design features of clinical cranial implants—what should automated methods strive to replicate?. International Journal of Computer Assisted Radiology and Surgery. 2024. doi:10.1007/s11548-024-03068-4

BibTeX
@article{Fishman2024,
  author = {Fishman, Z and Mainprize, James G and Edwards, Glenn and Antonyshyn, Oleh and Hardisty, Michael and Whyne, C M},
  title = {Thickness and design features of clinical cranial implants—what should automated methods strive to replicate?},
  journal = {International Journal of Computer Assisted Radiology and Surgery},
  year = {2024},
  doi = {10.1007/s11548-024-03068-4}
}
Kostenlos starten →