EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access · CC BY 4.0

Agreement between rhinomanometry and computed tomography-based computational fluid dynamics

Manuel Berger, Aris I Giotakis, Martin Pillei, Andreas Mehrle, Michael Kraxner, Florian Kral, Wolfgang Recheis, Herbert Riechelmann, Wolfgang Freysinger

International Journal of Computer Assisted Radiology and Surgery · 2021-04 · 16 (4) · 629-638

DOI: 10.1007/s11548-021-02332-1 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift International Journal of Computer Assisted Radiology and Surgery, online erschienen am 07.03.2021. Verfasst von Manuel Berger und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Environmental, Process and Energy Engineering, MCI, The Entrepreneurial School, Innsbruck, Austria. Hauptthemen laut MEDLINE: Hydrodynamics. Die Arbeit wurde bisher 23-mal zitiert (Crossref) und nennt 24 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Medizinische Universität Innsbruck, University of Innsbruck and Medical University of Innsbruck.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Active anterior rhinomanometry (AAR) and computed tomography (CT) are standardized methods for the evaluation of nasal obstruction. Recent attempts to correlate AAR with CT-based computational fluid dynamics (CFD) have been controversial. We aimed to investigate this correlation and agreement based on an in-house developed procedure.

Methods

In a pilot study, we retrospectively examined five subjects scheduled for septoplasty, along with preoperative digital volume tomography and AAR. The simulation was performed with Sailfish CFD, a lattice Boltzmann code. We examined the correlation and agreement of pressure derived from AAR (RhinoPress) and simulation (SimPress) and these of resistance during inspiration by 150 Pa pressure drop derived from AAR (RhinoRes150) and simulation (SimRes150). For investigation of correlation between pressures and between resistances, a univariate analysis of variance and a Pearson’s correlation were performed, respectively. For investigation of agreement, the Bland–Altman method was used.

Results

The correlation coefficient between RhinoPress and SimPress was r = 0.93 ( p < 0.001). RhinoPress was similar to SimPress in the less obstructed nasal side and two times greater than SimPress in the more obstructed nasal side. A moderate correlation was found between RhinoRes150 and SimRes150 ( r = 0.65; p = 0.041).

Conclusion

The simulation of rhinomanometry pressure by CT-based CFD seems more feasible with the lattice Boltzmann code in the less obstructed nasal side. In the more obstructed nasal side, error rates of up to 100% were encountered. Our results imply that the pressure and resistance derived from CT-based CFD and AAR were similar, yet not same.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

HydrodynamicsAdultAgedComputer SimulationCone-Beam Computed TomographyFemaleHumansMaleNasal ObstructionNasal SeptumPilot ProjectsReproducibility of ResultsRetrospective StudiesRhinomanometryRhinoplastySoftwareTomography, X-Ray ComputedYoung Adult

Stichwörter der Autor:innen

Agreement analysisComputational fluid dynamicsMethod comparisonNasal obstructionRhinomanometrySimulation

Autor:innen und Institutionen

  • Department of Environmental, Process and Energy Engineering, MCI, The Entrepreneurial School, Innsbruck, Austria.
  • Department of Otorhinolaryngology, Medical University of Innsbruck, Innsbruck, Austria.
  • Department of Otorhinolaryngology, Medical University of Innsbruck, Innsbruck, Austria. aristeidis.giotakis@i-med.ac.at.
  • Department of Fluid Mechanics, Friedrich-Alexander-University Erlangen-Nuremberg, Erlangen, Germany.
  • Department of Mechatronics, MCI, The Entrepreneurial School, Innsbruck, Austria.
  • University Hospital of Radiology, Medical University of Innsbruck, Innsbruck, Austria.

Förderung

  • Medizinische Universität Innsbruck
  • University of Innsbruck and Medical University of Innsbruck

Zitieren

APA

Berger, M., Giotakis, A. I., Pillei, M., Mehrle, A., Kraxner, M., Kral, F., Recheis, W., Riechelmann, H., & Freysinger, W. (2021). Agreement between rhinomanometry and computed tomography-based computational fluid dynamics. International Journal of Computer Assisted Radiology and Surgery, 16(4), 629-638. https://doi.org/10.1007/s11548-021-02332-1

Vancouver

Berger M, Giotakis AI, Pillei M, Mehrle A, Kraxner M, Kral F, et al. Agreement between rhinomanometry and computed tomography-based computational fluid dynamics. International Journal of Computer Assisted Radiology and Surgery. 2021;16(4):629-638. doi:10.1007/s11548-021-02332-1

BibTeX
@article{Berger2021,
  author = {Berger, Manuel and Giotakis, Aris I and Pillei, Martin and Mehrle, Andreas and Kraxner, Michael and Kral, Florian and Recheis, Wolfgang and Riechelmann, Herbert and Freysinger, Wolfgang},
  title = {Agreement between rhinomanometry and computed tomography-based computational fluid dynamics},
  journal = {International Journal of Computer Assisted Radiology and Surgery},
  year = {2021},
  volume = {16},
  number = {4},
  pages = {629--638},
  doi = {10.1007/s11548-021-02332-1}
}
Kostenlos starten →