EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Low-dose ultrahigh-resolution PCCT enhances subsolid nodule characterization

Qinqin Yan, Fuhua Yan, Qi Lin, Qiqi Cao, Yajie Zhang, Xiaoyan Chen, Bernhard Schmidt, Zhihan Xu, Wenjie Yang

La radiologia medica · 29.07.2025 · 130 (8) · 1207-1220

DOI: 10.1007/s11547-025-02057-0 ↗

Kurz gefasst

Fachartikel in der Zeitschrift La radiologia medica, online erschienen am 29.07.2025. Verfasst von Qinqin Yan und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Ruijin Hospital, Shanghai Jiaotong University School of Medicine, No.197, Ruijin Second Road, Huangpu District, Shanghai, Ch…. Hauptthemen laut MEDLINE: Tomography, X-Ray Computed, Lung Neoplasms, Adenocarcinoma of Lung, Multiple Pulmonary Nodules. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Key Research and Development Program of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To characterize invasion-associated CT features in pulmonary subsolid nodules using low-dose ultrahigh-resolution (UHR) photon-counting CT (PCCT) images and evaluate UHR’s diagnostic superiority over standard high-resolution (HR) images.

Methods

Patients with subsolid lung adenocarcinoma were recruited for chest scan on PCCT to obtain UHR and standard HR images between November 2023 and May 2024. Nodule characteristics were visually assessed and histogram features were extracted from each nodule. Image quality and radiation dose at previous energy-integrating detector CT (EID-CT) of 30 patients were compared with those of PCCT. Differences between UHR and standard HR, PCCT and EID-CT were compared using paired McNemar-test or paired Wilcox-test.

Results

One hundred and eighty-four patients with 203 subsolid nodules were collected including 77 precursors, 77 minimally invasive adenocarcinoma (MIA) and 49 IA. UHR significantly outperformed standard HR in revealing CT findings including larger nodular diameter and solid-component diameter, more frequency of heterogeneous attenuation, lobulation, bubble-like sign, air bronchogram, pleural indentation and vascular sign (all P < 0.05). Additionally, UHR images exhibited significantly greater value in histogram-derived parameters compared to standard HR images (all P < 0.05), except for “Median,” “Minimum.” Furthermore, the radiation dose in PCCT was half of that in EID-CT (effective dose: 1.32 ± 0.27 vs. 3.85 ± 1.65/mSv, P < 0.001. CDTI vol : 2.97 ± 0.53 vs. 6.90 ± 2.97/mGy, P < 0.001), with image quality significantly better in PCCT.

Conclusion

The UHR protocol on PCCT provides a magnified perspective to reveal CT characteristics of invasive growth in subsolid LUAD, previously undetectable on standard HR images, achieving halved radiation dose and better image quality than EID-CT.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Tomography, X-Ray ComputedLung NeoplasmsAdenocarcinoma of LungMultiple Pulmonary NodulesHumansMaleFemaleRadiation DosageMiddle AgedAgedRetrospective StudiesAged, 80 and over

Stichwörter der Autor:innen

Lung adenocarcinomaPhoton-counting CTSubsolid nodulesUltrahigh resolution

Autor:innen und Institutionen

  • Department of Radiology, Ruijin Hospital, Shanghai Jiaotong University School of Medicine, No.197, Ruijin Second Road, Huangpu District, Shanghai, China.
  • Department of Thoracic Surgery, Ruijin Hospital, Shanghai Jiaotong University School of Medicine, No.197, Ruijin Second Road, Huangpu District, Shanghai, China.
  • Department of Pathology, Ruijin Hospital, Shanghai Jiaotong University School of Medicine, No.197, Ruijin Second Road, Huangpu District, Shanghai, China.
  • Siemens Healthcare GmbH, Computed Tomography, Forchheim, Germany.
  • Department of CT Collaboration, Siemens Healthineers Ltd, Shanghai, China.
  • Department of Radiology, Ruijin Hospital, Shanghai Jiaotong University School of Medicine, No.197, Ruijin Second Road, Huangpu District, Shanghai, China. lisa_ywj@163.com.

Förderung

  • National Key Research and Development Program of China

Zitieren

APA

Yan, Q., Yan, F., Lin, Q., Cao, Q., Zhang, Y., Chen, X., Schmidt, B., Xu, Z., & Yang, W. (2025). Low-dose ultrahigh-resolution PCCT enhances subsolid nodule characterization. La radiologia medica, 130(8), 1207-1220. https://doi.org/10.1007/s11547-025-02057-0

Vancouver

Yan Q, Yan F, Lin Q, Cao Q, Zhang Y, Chen X, et al. Low-dose ultrahigh-resolution PCCT enhances subsolid nodule characterization. La radiologia medica. 2025;130(8):1207-1220. doi:10.1007/s11547-025-02057-0

BibTeX
@article{Yan2025,
  author = {Yan, Qinqin and Yan, Fuhua and Lin, Qi and Cao, Qiqi and Zhang, Yajie and Chen, Xiaoyan and Schmidt, Bernhard and Xu, Zhihan and Yang, Wenjie},
  title = {Low-dose ultrahigh-resolution PCCT enhances subsolid nodule characterization},
  journal = {La radiologia medica},
  year = {2025},
  volume = {130},
  number = {8},
  pages = {1207--1220},
  doi = {10.1007/s11547-025-02057-0}
}
Kostenlos starten →