Accuracy of abbreviated magnetic resonance compared to 3-dimensional mammography and ultrasound in early detection of breast cancer
La radiologia medica · 2025
DOI: 10.1007/s11547-025-01983-3 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift La radiologia medica, 2025. Verfasst von Sara El Garwany und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Suez Canal University, Ismailia, Egypt. Saramohammed2017@yahoo.com. Hauptthemen laut MEDLINE: Breast Neoplasms, Magnetic Resonance Imaging, Mammography, Early Detection of Cancer. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 39 Literaturangaben.
Abstract (Originalsprache)
BACKGROUND: The purpose of this study is to assess the usefulness of the novel abbreviated MR (AB-MR) protocol in the screening of women with an intermediate risk of breast cancer. Sixty women with a Tyrer-Cuzick model-determined intermediate risk of breast cancer underwent AB-MR, mammography, and tomosynthesis examinations; as an auxiliary procedure, ultrasound imaging was carried out. Every modality was allocated a final BI-RADS category. Time spent on acquisition and interpretation was also noted. Pathological confirmation was obtained in all cases exhibiting malignant findings. The difference in sensitivity and specificity between the two modalities was evaluated using McNemar's test. RESULTS: When compared to traditional screening methods, AB-MR demonstrated 100% NPV, 98% specificity, 66.7% PPV, and 100% sensitivity in women with intermediate risk of breast cancer. Comparing mammography/ultrasound to positive malignancies verified by biopsy, the results indicated 100% sensitivity, 96.5% specificity, 60% PPV, and 100% NPV. Complete agreement was observed between abbreviated MR and malignant biopsies (100% sensitivity, specificity, NPV, and PPV). For AB-MR and mammography, the average reading time was 4 min and 5 min, respectively. The average acquisition time for AB-MRI was around 10 min, whereas the average time for complete MR imaging is 17 min. CONCLUSION: AB-MR has better sensitivity, specificity, PPV, and NPV in screening of intermediate- and high-risk breast cancer. Acquisition time was shorter than full MR protocol. Reading time was decreased in respect of mammography. MRI screening ought to be more practical with the AB-MR protocol.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiology, Suez Canal University, Ismailia, Egypt. Saramohammed2017@yahoo.com.
- North West Imaging Academy, St Helens Road, L39 4QP, Ormskirk, United Kingdom. Saramohammed2017@yahoo.com.
- Department of Radiology, Suez Canal University, Ismailia, Egypt.
- Department of Radiology, Cairo University, Cairo, Egypt.
Zitieren
APA
Garwany, S. E., Gad, A. A., Mansour, S. M., Al-Shatouri, M. A., Alshafeiy, T., & AlSerafi, A. F. (2025). Accuracy of abbreviated magnetic resonance compared to 3-dimensional mammography and ultrasound in early detection of breast cancer. La radiologia medica. https://doi.org/10.1007/s11547-025-01983-3
Vancouver
Garwany SE, Gad AA, Mansour SM, Al-Shatouri MA, Alshafeiy T, AlSerafi AF. Accuracy of abbreviated magnetic resonance compared to 3-dimensional mammography and ultrasound in early detection of breast cancer. La radiologia medica. 2025. doi:10.1007/s11547-025-01983-3
BibTeX
@article{Garwany2025,
author = {Garwany, Sara El and Gad, Azza Abdel-Hamid and Mansour, Sahar Mahmoud and Al-Shatouri, Mohammad Ahmed and Alshafeiy, Taghreed and AlSerafi, Ahmed Fathy},
title = {Accuracy of abbreviated magnetic resonance compared to 3-dimensional mammography and ultrasound in early detection of breast cancer},
journal = {La radiologia medica},
year = {2025},
doi = {10.1007/s11547-025-01983-3}
}
EUVIMED