EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Automated spinopelvic measurements on radiographs with artificial intelligence: a multi-reader study

Boj Friedrich Hoppe, Johannes Rueckel, Jan Rudolph, Nicola Fink, Simon Weidert, Wolf Hohlbein, Adrian Cavalcanti-Kußmaul, Lena Trappmann, Basel Munawwar, Jens Ricke, Bastian Oliver Sabel

La radiologia medica · 26.01.2025

DOI: 10.1007/s11547-025-01957-5 ↗

Kurz gefasst

Fachartikel in der Zeitschrift La radiologia medica, online erschienen am 26.01.2025. Verfasst von Boj Friedrich Hoppe und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, University Hospital, LMU Munich, Marchioninistr. 15, 81377, Munich, Germany. boj.hoppe@med.lmu.de. Hauptthemen laut MEDLINE: Artificial Intelligence, Spine, Radiography, Radiographic Image Interpretation, Computer-Assisted. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 41 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Siemens Healthineers, Klinikum der Universität München.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To develop an artificial intelligence (AI) algorithm for automated measurements of spinopelvic parameters on lateral radiographs and compare its performance to multiple experienced radiologists and surgeons.

Methods

On lateral full-spine radiographs of 295 consecutive patients, a two-staged region-based convolutional neural network (R-CNN) was trained to detect anatomical landmarks and calculate thoracic kyphosis (TK), lumbar lordosis (LL), sacral slope (SS), and sagittal vertical axis (SVA). Performance was evaluated on 65 radiographs not used for training, which were measured independently by 6 readers (3 radiologists, 3 surgeons), and the median per measurement was set as the reference standard. Intraclass correlation coefficient (ICC), mean absolute error (MAE), and standard deviation (SD) were used for statistical analysis; while, ANOVA was used to search for significant differences between the AI and human readers.

Results

Automatic measurements (AI) showed excellent correlation with the reference standard, with all ICCs within the range of the readers (TK: 0.92 [AI] vs. 0.85–0.96 [readers]; LL: 0.95 vs. 0.87–0.98; SS: 0.93 vs. 0.89–0.98; SVA: 1.00 vs. 0.99–1.00; all p < 0.001). Analysis of the MAE (± SD) revealed comparable results to the six readers (TK: 3.71° (± 4.24) [AI] v.s 1.86–5.88° (± 3.48–6.17) [readers]; LL: 4.53° ± 4.68 vs. 2.21–5.34° (± 2.60–7.38); SS: 4.56° (± 6.10) vs. 2.20–4.76° (± 3.15–7.37); SVA: 2.44 mm (± 3.93) vs. 1.22–2.79 mm (± 2.42–7.11)); while, ANOVA confirmed no significant difference between the errors of the AI and any human reader (all p > 0.05). Human reading time was on average 139 s per case (range: 86–231 s).

Conclusion

Our AI algorithm provides spinopelvic measurements accurate within the variability of experienced readers, but with the potential to save time and increase reproducibility.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Artificial IntelligenceSpineRadiographyRadiographic Image Interpretation, Computer-AssistedHumansFemaleMaleMiddle AgedAlgorithmsAgedAdultObserver VariationNeural Networks, ComputerRetrospective Studies

Stichwörter der Autor:innen

Artificial IntelligenceDeep LearningRadiographsSpinopelvic Measurements

Autor:innen und Institutionen

  • Department of Radiology, University Hospital, LMU Munich, Marchioninistr. 15, 81377, Munich, Germany. boj.hoppe@med.lmu.de.
  • Department of Radiology, University Hospital, LMU Munich, Marchioninistr. 15, 81377, Munich, Germany.
  • Institute of Neuroradiology, University Hospital, LMU Munich, Munich, Germany.
  • Department of Orthopaedics and Trauma Surgery, Musculoskeletal University Center Munich (MUM), University Hospital, LMU Munich, Munich, Germany.

Förderung

  • Siemens Healthineers
  • Klinikum der Universität München

Zitieren

APA

Hoppe, B. F., Rueckel, J., Rudolph, J., Fink, N., Weidert, S., Hohlbein, W., Cavalcanti-Kußmaul, A., Trappmann, L., Munawwar, B., Ricke, J., & Sabel, B. O. (2025). Automated spinopelvic measurements on radiographs with artificial intelligence: a multi-reader study. La radiologia medica. https://doi.org/10.1007/s11547-025-01957-5

Vancouver

Hoppe BF, Rueckel J, Rudolph J, Fink N, Weidert S, Hohlbein W, et al. Automated spinopelvic measurements on radiographs with artificial intelligence: a multi-reader study. La radiologia medica. 2025. doi:10.1007/s11547-025-01957-5

BibTeX
@article{Hoppe2025,
  author = {Hoppe, Boj Friedrich and Rueckel, Johannes and Rudolph, Jan and Fink, Nicola and Weidert, Simon and Hohlbein, Wolf and Cavalcanti-Kußmaul, Adrian and Trappmann, Lena and Munawwar, Basel and Ricke, Jens and Sabel, Bastian Oliver},
  title = {Automated spinopelvic measurements on radiographs with artificial intelligence: a multi-reader study},
  journal = {La radiologia medica},
  year = {2025},
  doi = {10.1007/s11547-025-01957-5}
}
Kostenlos starten →