Single-Lead EEG-based virtual reality motion sickness detection using interpretable feature selection
Medical & Biological Engineering & Computing · 2026
DOI: 10.1007/s11517-026-03702-0 ↗Kurz gefasst
Fachartikel in der Zeitschrift Medical & Biological Engineering & Computing, 2026. Verfasst von Min Zhu und 6 weiteren Autor:innen. Beteiligte Einrichtung: School of Automation, C-IMER, CICAEET, Nanjing University of Information Science & Technology, Nanjing, 210044, China. Hauptthemen laut MEDLINE: Electroencephalography, Motion Sickness, Virtual Reality, Signal Processing, Computer-Assisted. Die Arbeit nennt 55 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Natural Science Foundation of Jiangsu Province, Startup Foundation for Introducing Talent of Nanjing University of Information Science and Technology.
Abstract (Originalsprache)
Background
Electroencephalography (EEG) is a key method for detecting virtual reality motion sickness (VRMS), but multi-lead recordings and high-dimensional features increase processing complexity, device cost, and user burden.
Objective
This study proposes a SHapley Additive exPlanations (SHAP)-based single-lead modeling and feature-screening framework to reduce the number of EEG leads and feature dimensions for lightweight VRMS detection.
Method
Six classical deep-learning EEG decoding models were used to assess the contribution of each lead via SHAP values and identify the optimal single lead. Handcrafted features were then extracted and selected using a correlation–SHAP strategy, and XGBoost was adopted for final classification.
Results
FT11 showed competitive and relatively consistent performance across the evaluated models and was selected as the target lead after integrating SHAP-based lead importance, single-lead classification performance, frequency-band differences, and physiological relevance. Under the window-level tenfold cross-validation protocol used in this study, the proposed model achieved an accuracy of 87.53% ± 0.73% using seven selected features, which was 9.55 percentage points lower than the full-lead full-feature model and 0.69 percentage points lower than the single-lead full-feature model. Significance These findings demonstrate an interpretable framework for identifying a compact single-lead and feature configuration for VRMS-related EEG discrimination. An additional post hoc LOSO test of the globally selected configuration showed limited performance on held-out participants. Because the lead, classifier, and feature configuration had been selected globally before LOSO testing, these results should not be interpreted as a fully independent estimate of cross-subject generalization. Graphical Abstract
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- School of Automation, C-IMER, CICAEET, Nanjing University of Information Science & Technology, Nanjing, 210044, China.
- School of Automation, C-IMER, CICAEET, Nanjing University of Information Science & Technology, Nanjing, 210044, China. huachengcheng@nuist.edu.cn.
Förderung
- National Natural Science Foundation of China
- Natural Science Foundation of Jiangsu Province
- Startup Foundation for Introducing Talent of Nanjing University of Information Science and Technology
Zitieren
APA
Zhu, M., Hua, C., Wang, Q., Fu, J., Xiang, S., Wei, Z., & Liu, J. (2026). Single-Lead EEG-based virtual reality motion sickness detection using interpretable feature selection. Medical & Biological Engineering & Computing. https://doi.org/10.1007/s11517-026-03702-0
Vancouver
Zhu M, Hua C, Wang Q, Fu J, Xiang S, Wei Z, et al. Single-Lead EEG-based virtual reality motion sickness detection using interpretable feature selection. Medical & Biological Engineering & Computing. 2026. doi:10.1007/s11517-026-03702-0
BibTeX
@article{Zhu2026,
author = {Zhu, Min and Hua, Chengcheng and Wang, Qiuyu and Fu, Jingqi and Xiang, Sheng and Wei, Zhong and Liu, Jia},
title = {Single-Lead EEG-based virtual reality motion sickness detection using interpretable feature selection},
journal = {Medical & Biological Engineering & Computing},
year = {2026},
doi = {10.1007/s11517-026-03702-0}
}
EUVIMED