EUVIMEDEUVIMED entdecken
Crossref

Biomechanical assessment of vertebral fracture risk incorporating the effect of paraspinal muscles

Yuhan Zhao, Rahman Ud Din, Jinping Dong, Xiaoguang Cheng, Haisheng Yang

Medical & Biological Engineering & Computing · 2026-05 · 64 (5) · 1635-1648

DOI: 10.1007/s11517-026-03557-5 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Medical & Biological Engineering & Computing, online erschienen am 10.03.2026. Verfasst von Yuhan Zhao und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedical Engineering, College of Chemistry and Life Science, Beijing University of Technology, 100 Pingleyuan, Chaoyang District, Bei…. Hauptthemen laut MEDLINE: Spinal Fractures, Paraspinal Muscles. Die Arbeit nennt 55 Literaturangaben. Gefördert von: Natural Science Foundation of Beijing Municipality.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Vertebral fractures are a major public health issue worldwide. Current assessment standards, like volumetric bone mineral density (vBMD), are limited because they overlook the critical biomechanical role of paraspinal muscles. This study directly compares quasistatic and musculoskeletal models on their performance in estimating the load-to-strength ratio (LSR) and determines their efficacy in vertebral fracture risk assessment. Our case-control study included 70 subjects (18 with vertebral fractures and 52 controls) who underwent quantitative CT for vBMD measurement and finite element analysis, which yielded biomechanical CT (BCT) to determine vertebral strength. The compressive loads on L2 vertebra under three postures (30°, 45°, and 90° flexion) were computed and LSRs were calculated. Group differences in vBMD, BCT strength, muscle density, and LSRs were compared, while their diagnostic performance was evaluated. For fracture risk assessment, LSRs demonstrated higher performance (AUC: 0.89–0.94) vs. vBMD (AUC: 0.71), and certain improvements over BCT-strength. Quasistatic and musculoskeletal models produced similar loads at 30° and 45°, while musculoskeletal model predicted markedly higher loads at 90° (+ 48.4%). Overall, incorporating paraspinal muscle-related loading into LSR improves fracture risk assessment beyond vBMD. Model choice becomes more influential under high-flexion conditions.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Spinal FracturesParaspinal MusclesHumansFemaleBiomechanical PhenomenaMaleCase-Control StudiesBone DensityFinite Element AnalysisTomography, X-Ray ComputedAgedMiddle AgedLumbar VertebraeRisk Assessment

Stichwörter der Autor:innen

Biomechanical CTFinite element analysisLoad-to-strength ratioParaspinal musclesVertebral fracture

Autor:innen und Institutionen

  • Department of Biomedical Engineering, College of Chemistry and Life Science, Beijing University of Technology, 100 Pingleyuan, Chaoyang District, Beijing, 100124, China.
  • Department of Radiology, Beijing Jishuitan Hospital, Beijing, 100035, China.
  • Department of Biomedical Engineering, College of Chemistry and Life Science, Beijing University of Technology, 100 Pingleyuan, Chaoyang District, Beijing, 100124, China. haisheng.yang@bjut.edu.cn.

Förderung

  • Natural Science Foundation of Beijing Municipality

Zitieren

APA

Zhao, Y., Din, R. U., Dong, J., Cheng, X., & Yang, H. (2026). Biomechanical assessment of vertebral fracture risk incorporating the effect of paraspinal muscles. Medical & Biological Engineering & Computing, 64(5), 1635-1648. https://doi.org/10.1007/s11517-026-03557-5

Vancouver

Zhao Y, Din RU, Dong J, Cheng X, Yang H. Biomechanical assessment of vertebral fracture risk incorporating the effect of paraspinal muscles. Medical & Biological Engineering & Computing. 2026;64(5):1635-1648. doi:10.1007/s11517-026-03557-5

BibTeX
@article{Zhao2026,
  author = {Zhao, Yuhan and Din, Rahman Ud and Dong, Jinping and Cheng, Xiaoguang and Yang, Haisheng},
  title = {Biomechanical assessment of vertebral fracture risk incorporating the effect of paraspinal muscles},
  journal = {Medical & Biological Engineering & Computing},
  year = {2026},
  volume = {64},
  number = {5},
  pages = {1635--1648},
  doi = {10.1007/s11517-026-03557-5}
}