A multi-level segmentation-guided diffusion model for streak artifact reduction in routine non-contrast chest CT
Medical & Biological Engineering & Computing · 2026
DOI: 10.1007/s11517-026-03515-1 ↗Kurz gefasst
Fachartikel in der Zeitschrift Medical & Biological Engineering & Computing, 2026. Verfasst von Jingxin Liu und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, China-Japan Union Hospital of Jilin University, 126 Xiantai Blvd, Changchun, 130033, China. jingxin@jlu.edu.cn. Hauptthemen laut MEDLINE: Artifacts, Tomography, X-Ray Computed, Image Processing, Computer-Assisted, Radiography, Thoracic. Die Arbeit nennt 45 Literaturangaben. Gefördert von: the National Key R&D Program of China, the Jilin Provincial Department of Science and Technology.
Abstract (Originalsprache)
Streak artifacts in non-contrast computed tomography (NCCT) can obscure anatomical details and even confuse radiologic signs. Existing methods for artifact reduction have limitations: specialized training data and high annotation costs hinder the performance scalability, inadequate anatomical constraints struggle to preserve fine details, and limited generative stability along with suboptimal artifact reduction compromises diagnostic applicability. Leveraging 96,641 CT slices (763 series) from four different CT scanners (100-140 kilovolt peak (kVp), 55-167 tube current-time product (mAs), 0.5-10 mm thickness), we proposed a novel guided diffusion method using multi-level anatomical segmentations to optimize streak artifact reduction in chest NCCT scans. During training, the model integrates artifact-free CT slices with segmentation maps and anatomical regions of interest (ROIs) via channel-wise concatenation at each diffusion step. During inference, artifact-affected samples are fed into the trained model to generate artifact-free outputs with structural integrity. Statistical analysis revealed a significant (p 0.05). Compared to four novel studies, our method achieved superior overall Peak Signal-to-Noise Ratio (PSNR) (36.952, SD 0.671), Structural Similarity Index (SSIM) (0.863, SD 0.013), and Dice Similarity Coefficient (DSC) (0.959, SD 0.031), with all p < 0.05. Moreover, ablation studies indicated that an appropriate segmentation guidance (Level-2) optimally balances anatomical structure constraints and artifact reduction efficiency, demonstrating superior performance in distinct organ or tissue regions compared to coarser and finer-grained guidance strategies. The proposed method has the potential to improve clinical analysis for chest NCCT by optimizing streak artifact reduction while enhancing medical image quality.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiology, China-Japan Union Hospital of Jilin University, 126 Xiantai Blvd, Changchun, 130033, China. jingxin@jlu.edu.cn.
- Jilin Engineering Technology Research Center for Medical Imaging, China-Japan Union Hospital of Jilin University, 126 Xiantai Blvd, Changchun, 130033, China. jingxin@jlu.edu.cn.
- Department of Radiology, China-Japan Union Hospital of Jilin University, 126 Xiantai Blvd, Changchun, 130033, China.
- Jilin Engineering Technology Research Center for Medical Imaging, China-Japan Union Hospital of Jilin University, 126 Xiantai Blvd, Changchun, 130033, China.
- Department of Medical Oncology Ward I, China-Japan Union Hospital of Jilin University, 126 Xiantai Blvd, Changchun, 130033, China.
- Jilin Engineering Technology Research Center for Medical Imaging, China-Japan Union Hospital of Jilin University, 126 Xiantai Blvd, Changchun, 130033, China. mirotical@hotmail.com.
Förderung
- the National Key R&D Program of China
- the Jilin Provincial Department of Science and Technology
Zitieren
APA
Liu, J., Zhu, X., Shi, Z., An, D., Zu, L., Cheng, K., & Zhang, Z. (2026). A multi-level segmentation-guided diffusion model for streak artifact reduction in routine non-contrast chest CT. Medical & Biological Engineering & Computing. https://doi.org/10.1007/s11517-026-03515-1
Vancouver
Liu J, Zhu X, Shi Z, An D, Zu L, Cheng K, et al. A multi-level segmentation-guided diffusion model for streak artifact reduction in routine non-contrast chest CT. Medical & Biological Engineering & Computing. 2026. doi:10.1007/s11517-026-03515-1
BibTeX
@article{Liu2026,
author = {Liu, Jingxin and Zhu, Xinran and Shi, Zhangzhen and An, Donghong and Zu, Lihui and Cheng, Kailiang and Zhang, Zhong},
title = {A multi-level segmentation-guided diffusion model for streak artifact reduction in routine non-contrast chest CT},
journal = {Medical & Biological Engineering & Computing},
year = {2026},
doi = {10.1007/s11517-026-03515-1}
}
EUVIMED