Real-time beat-to-beat pulse wave velocity estimation: a quality-driven approach using laser Doppler vibrometry
Medical & Biological Engineering & Computing · 2025
DOI: 10.1007/s11517-025-03417-8 ↗Kurz gefasst
Fachartikel in der Zeitschrift Medical & Biological Engineering & Computing, 2025. Verfasst von Silvia Seoni und 11 weiteren Autor:innen. Beteiligte Einrichtung: Biolab, PoliTo BIOMed Lab, Department of Electronics and Telecommunications, Politecnico di Torino, Corso Duca degli Abruzzi 24, 10129 , Turin, Italy…. Hauptthemen laut MEDLINE: Pulse Wave Analysis, Laser-Doppler Flowmetry. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Horizon 2020 Framework Programme, Politecnico di Torino.
Abstract (Originalsprache)
Arterial stiffness, a key cardiovascular risk marker, is typically assessed via carotid-femoral pulse wave velocity (cf-PWV), the gold-standard method. In this study, we introduce CAPE (Continuous Automatic PWV Estimation), an innovative framework for near real-time cf-PWV estimation based on beat-to-beat analysis of laser-Doppler vibrometry (LDV) signals. CAPE integrates automatic fiducial point detection, systematic signal quality control, and a cross-channel strategy to provide a highly reliable assessment of cf-PWV. The framework was evaluated using LDV signals acquired from 100 patients with mild to moderate essential hypertension, using a multichannel laser vibrometry system. CAPE calculates cf-PWV as the ratio of carotid-femoral distance to pulse transit time (PTT), which is the delay between carotid and femoral fiducial points. These points are detected using template-matching on the second derivative of LDV displacement signals. Signal quality in CAPE is ensured through an integrated quality assessment based on the number of automatically detected carotid-femoral peaks, which assigns confidence scores (acceptable or excellent) to the PWV measurements. When validated against the gold-standard applanation tonometry, CAPE achieved a mean bias of 0.25 ± 0.77 m/s, demonstrating high reliability and precision. The optimized framework estimates cf-PWV in 3 s, making CAPE ideal for clinical applications requiring real-time cardiovascular assessment. Graphical abstract
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Biolab, PoliTo BIOMed Lab, Department of Electronics and Telecommunications, Politecnico di Torino, Corso Duca degli Abruzzi 24, 10129 , Turin, Italy. silvia.seoni@polito.it.
- BioMMeda - Institute for Biomedical Engineering and Technology, Ghent University, Ghent, Belgium.
- Biolab, PoliTo BIOMed Lab, Department of Electronics and Telecommunications, Politecnico di Torino, Corso Duca degli Abruzzi 24, 10129 , Turin, Italy.
- Laboratory of Integrative Physiology, Department of Neuroscience, Università di Torino, c.so Raffaello 30, Torino, 10125, Italy.
- Paris Centre de Recherche Cardiovasculaire, INSERM, Paris, France.
- Assistance Publique Hôpitaux de Paris, Hôpital Européen Georges Pompidou, Paris, France.
Förderung
- Horizon 2020 Framework Programme
- Politecnico di Torino
Zitieren
APA
Seoni, S., Segers, P., Beeckman, S., Salvi, M., Romanelli, M., Badhwar, S., Bruno, R. M., Li, Y., Aasmul, S., Madhu, N., Molinari, F., & Morbiducci, U. (2025). Real-time beat-to-beat pulse wave velocity estimation: a quality-driven approach using laser Doppler vibrometry. Medical & Biological Engineering & Computing. https://doi.org/10.1007/s11517-025-03417-8
Vancouver
Seoni S, Segers P, Beeckman S, Salvi M, Romanelli M, Badhwar S, et al. Real-time beat-to-beat pulse wave velocity estimation: a quality-driven approach using laser Doppler vibrometry. Medical & Biological Engineering & Computing. 2025. doi:10.1007/s11517-025-03417-8
BibTeX
@article{Seoni2025,
author = {Seoni, Silvia and Segers, Patrick and Beeckman, Simeon and Salvi, Massimo and Romanelli, Marco and Badhwar, Smriti and Bruno, Rosa Maria and Li, Yanlu and Aasmul, Soren and Madhu, Nilesh and Molinari, Filippo and Morbiducci, Umberto},
title = {Real-time beat-to-beat pulse wave velocity estimation: a quality-driven approach using laser Doppler vibrometry},
journal = {Medical & Biological Engineering & Computing},
year = {2025},
doi = {10.1007/s11517-025-03417-8}
}
EUVIMED