Rapid wall shear stress prediction for aortic aneurysms using deep learning: a fast alternative to CFD
Medical & Biological Engineering & Computing · 2025-07 · 63 (7) · 2173-2190
DOI: 10.1007/s11517-025-03311-3 ↗Kurz gefasst
Fachartikel in der Zeitschrift Medical & Biological Engineering & Computing, online erschienen am 17.02.2025. Verfasst von Md Ahasan Atick Faisal und 10 weiteren Autor:innen. Beteiligte Einrichtung: Biomedical Research Center, Qatar University, Doha, 2713, Qatar. Hauptthemen laut MEDLINE: Deep Learning, Stress, Mechanical, Aortic Aneurysm, Abdominal. Die Arbeit wurde bisher 13-mal zitiert (Crossref) und nennt 58 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Qatar National Research Fund.
Abstract (Originalsprache)
Aortic aneurysms pose a significant risk of rupture. Previous research has shown that areas exposed to low wall shear stress (WSS) are more prone to rupture. Therefore, precise WSS determination on the aneurysm is crucial for rupture risk assessment. Computational fluid dynamics (CFD) is a powerful approach for WSS calculations, but they are computationally intensive, hindering time-sensitive clinical decision-making. In this study, we propose a deep learning (DL) surrogate, MultiViewUNet, to rapidly predict time-averaged WSS (TAWSS) distributions on abdominal aortic aneurysms (AAA). Our novel approach employs a domain transformation technique to translate complex aortic geometries into representations compatible with state-of-the-art neural networks. MultiViewUNet was trained on $$\varvec{23}$$ 23 real and $$\varvec{230}$$ 230 synthetic AAA geometries, demonstrating an average normalized mean absolute error (NMAE) of just $$\varvec{0.362\%}$$ 0.362 % in WSS prediction. This framework has the potential to streamline hemodynamic analysis in AAA and other clinical scenarios where fast and accurate stress quantification is essential. Graphical abstract
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Biomedical Research Center, Qatar University, Doha, 2713, Qatar.
- Department of Electrical Engineering, Qatar University, Doha, 2713, Qatar.
- Electrical and Computer Engineering Department, The University of British Columbia, Vancouver, V6T 1Z4, BC, Canada.
- Heart Hospital, Hamad Medical Corporation, Doha, 3050, Qatar.
- Department of Mechanical Engineering, Middle East Technical University, Ankara, 06800, Turkey.
- Department of Surgery, Trauma, and Vascular Surgery, Hamad Medical Corporation, Doha, 3050, Qatar.
Förderung
- Qatar National Research Fund
Zitieren
APA
Faisal, M. A. A., Mutlu, O., Mahmud, S., Tahir, A., Chowdhury, M. E. H., Bensaali, F., Alnabti, A., Yavuz, M. M., El-Menyar, A., Al-Thani, H., & Yalcin, H. C. (2025). Rapid wall shear stress prediction for aortic aneurysms using deep learning: a fast alternative to CFD. Medical & Biological Engineering & Computing, 63(7), 2173-2190. https://doi.org/10.1007/s11517-025-03311-3
Vancouver
Faisal MAA, Mutlu O, Mahmud S, Tahir A, Chowdhury MEH, Bensaali F, et al. Rapid wall shear stress prediction for aortic aneurysms using deep learning: a fast alternative to CFD. Medical & Biological Engineering & Computing. 2025;63(7):2173-2190. doi:10.1007/s11517-025-03311-3
BibTeX
@article{Faisal2025,
author = {Faisal, Md Ahasan Atick and Mutlu, Onur and Mahmud, Sakib and Tahir, Anas and Chowdhury, Muhammad E H and Bensaali, Faycal and Alnabti, Abdulrahman and Yavuz, Mehmet Metin and El-Menyar, Ayman and Al-Thani, Hassan and Yalcin, Huseyin Cagatay},
title = {Rapid wall shear stress prediction for aortic aneurysms using deep learning: a fast alternative to CFD},
journal = {Medical & Biological Engineering & Computing},
year = {2025},
volume = {63},
number = {7},
pages = {2173--2190},
doi = {10.1007/s11517-025-03311-3}
}
EUVIMED