An arbitrary waveform neurostimulator for preclinical studies: design and verification
Medical & Biological Engineering & Computing · 2025-04 · 63 (4) · 1143-1159
DOI: 10.1007/s11517-024-03241-6 ↗Kurz gefasst
Fachartikel in der Zeitschrift Medical & Biological Engineering & Computing, online erschienen am 12.12.2024. Verfasst von Hipolito Guzman-Miranda und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Electronic Engineering, Universidad de Sevilla, Camino de los Descubrimientos, S/N, 41092, Sevilla, Spain. Hauptthemen laut MEDLINE: Electric Stimulation, Implantable Neurostimulators. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 53 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Ministerio de Ciencia e Innovación, Fundaluce, H2020 Marie Skłodowska-Curie Actions.
Abstract (Originalsprache)
Neural electrostimulation has enabled different therapies to treat a number of health problems. For example, the cochlear implant allows for recovering the hearing function and deep brain electrostimulation has been proved to reduce tremor in Parkinson’s disease. Other approaches such as retinal prostheses are progressing rapidly, as researchers continue to investigate new strategies to activate targeted neurons more precisely. The use of arbitrary current waveform electrosimulation is a promising technique that allows exploiting the differences that exist among different neural types to enable preferential activation. This work presents a two-channel arbitrary waveform neurostimulator designed for visual prosthetics research. A field programmable gate array (FPGA) was employed to control and generate voltage waveforms via digital-to-analog converters. Voltage waveforms were then electrically isolated and converted to current waveforms using a modified Howland amplifier. Shorting of the electrodes was provided using multiplexers. The FPGA gateware was verified to a high level of confidence using a transaction-level modeled testbench, achieving a line coverage of 91.4%. The complete system was tested in saline using silver electrodes with diameters from 200 to 1000 µm. The bandwidth obtained was 30 kHz with voltage compliance ± 15 V. The neurostimulator can be easily scaled up using the provided in/out trigger ports and adapted to other applications with minor modifications. Graphical Abstract
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Electronic Engineering, Universidad de Sevilla, Camino de los Descubrimientos, S/N, 41092, Sevilla, Spain.
- Department of Applied Physics III, Universidad de Sevilla, Camino de los Descubrimientos, S/N, 41092, Sevilla, Spain. abrivera@us.es.
- School of Biomedical Engineering, University of Sydney, Camperdown, NSW, 2050, Australia. abrivera@us.es.
Förderung
- Ministerio de Ciencia e Innovación
- Fundaluce
- H2020 Marie Skłodowska-Curie Actions
Zitieren
APA
Guzman-Miranda, H., & Barriga-Rivera, A. (2025). An arbitrary waveform neurostimulator for preclinical studies: design and verification. Medical & Biological Engineering & Computing, 63(4), 1143-1159. https://doi.org/10.1007/s11517-024-03241-6
Vancouver
Guzman-Miranda H, Barriga-Rivera A. An arbitrary waveform neurostimulator for preclinical studies: design and verification. Medical & Biological Engineering & Computing. 2025;63(4):1143-1159. doi:10.1007/s11517-024-03241-6
BibTeX
@article{GuzmanMiranda2025,
author = {Guzman-Miranda, Hipolito and Barriga-Rivera, Alejandro},
title = {An arbitrary waveform neurostimulator for preclinical studies: design and verification},
journal = {Medical & Biological Engineering & Computing},
year = {2025},
volume = {63},
number = {4},
pages = {1143--1159},
doi = {10.1007/s11517-024-03241-6}
}